Download Print this page

Lumascape LS411LED Installation Instructions Manual

Spotlight & floodlight

Advertisement

Quick Links

Lumascape Lighting Industries Pty Ltd
38-44 Enterprise Street, Cleveland, QLD 4163, Australia
PO Box 1875, Cleveland D.C., QLD 4163, Australia
T 07 3286 2299
F 07 3286 6599
E sales@lumascape.com.au
W www.lumascape.com.au
NO POWER
KEEP AWAY FROM
DO NOT USE SILICONE
TOOLS
FLAMMABLE MATERIAL
ON OUTSIDE SURFACE
LS411LED Omnio Mini
Warranty void if not installed as per installation instructions
DANGER
ISOLATE LUMINAIRE FROM POWER
Failure to isolate power
supply before installation or
maintenance may result in
fire, serious injury, electric
shock, death and may
damage the luminaire.
IMPORTANT
For All Mounting Options
Select a suitable power supply and locate centrally in relation to desired luminaire locations.
Use discretion in placement as luminaire can become very hot and may burn. Run conduit
and drill / cast holes as specified. Run cables. Maximum distance for remote drivers is 30 m
from the luminaire. Use table on right to select a suitable supply cable with the appropriate
number of conductors for the luminaire you are installing.
Surface Mount Base
Select the grommet to suit wiring conductors. For correct cable selection refer
1.
to table on top right. Screw mounting base to mounting accessory or screw
directly to mounting surface using 4 screws provided (holes for mounting
screws may be supplied blind. Drill through as required with a 4.5 mm drill. A
screw must be used for each hole drilled to achieve IP67 rating.)
www.lumascape.com.au
KEEP ELECTRONICS FREE
DO NOT HOSE OR
PREASSURE CLEAN
FROM DIRT AND MOISTURE
WARNING
Luminaire can become very hot.
Use discretion in placement.
Ensure that installation complies
with local authority standards.
All connections must be kept
dry; failure to do so may result
in product reliability issues.
Screw seals and sleeve must be
fitted or warranty void.
NOTE: Use only 1 x circular
cable to keep IP rating
Copyright ©2014 Lumascape Lighting Industries Pty. Ltd. ABN 21 010 572 773
INSTALLATION INSTRUCTIONS
INSTALLATION TyPE Surface Mount Base
SUPPLy VOLTAGE 100-240 V AC, 50/60 Hz
INSTRUCTIONS COVER Single Colour
Select Mounting Option
See individual mounting accessory
instructions overleaf
OR
LS411
Surface Mount
Base
Luminaire Type
Single colour, low-voltage, non-dimmable
Single colour, low-voltage, dimmable
Single colour, mains-voltage, non-dimmable
Integral RGB driver
Remote RGB driver
Terminate luminaire. Single colour, non-dimmable, mains-voltage
2.
version depicted in example. Refer to wiring diagrams below
for details. Earth lug connection only required for mains voltage
version of luminaire.
isolated prior to connection
or disconnection of cables.
Earth lug only required
for mains voltage
see over for wiring diagrams
SPOTLIGHT & FLOODLIGHT
MODEL LS411LED
Pole Clamp (LS6023)
Signage System (LS6025)
Concrete Anchor / Spike
IP RATING IP67
24 V DC Ripple Free Supply
12 V AC Magnetic Transformer
Single Colour Dimming
RGB (Integral & Remote Driver)
LS6023
(ordered separately)
OR
LS411
LS6025
Adaptor Base
(ordered separately)
No. of supply cores needed
Power supply must be
E
IN0025 - 6 August 2014
N653
LS411
Concrete Anchor /
Spike
2
4
3
6
6

Advertisement

loading
Need help?

Need help?

Do you have a question about the LS411LED and is the answer not in the manual?

Questions and answers

Summary of Contents for Lumascape LS411LED

  • Page 1 Earth lug only required for mains voltage NOTE: Use only 1 x circular cable to keep IP rating see over for wiring diagrams www.lumascape.com.au IN0025 - 6 August 2014 Copyright ©2014 Lumascape Lighting Industries Pty. Ltd. ABN 21 010 572 773...
  • Page 2 5 mm Allen key supplied. IMPORTANT: Attach screw seals 5 Nm Sleeve must meet base base screw seal 0.5 Nm Peel back sleeve to tighten screws www.lumascape.com.au IN0025 - 6 August 2014 Copyright ©2014 Lumascape Lighting Industries Pty. Ltd. ABN 21 010 572 773...
  • Page 3 PWM + White Green - PWM Red Blue Blue + Green PWM Green Green PWM - Black Blue - Blue PWM Blue Blue www.lumascape.com.au IN0025 - 6 August 2014 Copyright ©2014 Lumascape Lighting Industries Pty. Ltd. ABN 21 010 572 773...
  • Page 4 Mounting Stud Remove base from luminaire and feed through Screw luminaire base onto mounting stud. supply cable. Terminate supply cable. Base of luminaire www.lumascape.com.au IN0025 - 6 August 2014 Copyright ©2014 Lumascape Lighting Industries Pty. Ltd. ABN 21 010 572 773...
  • Page 5 Black Blue - Blue PWM Blue Blue Finalise installation and aim as desired. Refer to Surface Mount Base section for lamping instructions. www.lumascape.com.au IN0025 - 6 August 2014 Copyright ©2014 Lumascape Lighting Industries Pty. Ltd. ABN 21 010 572 773...
  • Page 6 PWM Red Do not connect if dimming is not required Blue Blue + Green PWM Green Black Blue - Blue PWM Blue www.lumascape.com.au IN0025 - 6 August 2014 Copyright ©2014 Lumascape Lighting Industries Pty. Ltd. ABN 21 010 572 773...
  • Page 7: Safety Instructions

    2. Luminaires to be used for intended purpose only. 3. Do not operate the luminaires with a missing or damaged parts. 4. Use only genuine Lumascape parts to replace damaged or missing components. 5. Refer to instructions for installation and operating requirements.