Download Print this page
KEPCO FAW 5-30K Instruction Manual

KEPCO FAW 5-30K Instruction Manual

Single output 150 watt high frequency switching power supplies

Advertisement

Quick Links

I N S T R U C T I O N M A N U A L
KEPCO
HIGH FREQUENCY SWITCHING POWER SUPPLIES
I — INTRODUCTION
The Kepco FAW 150 Watt Series low profile high frequency switching power supplies employ forward conversion and operate with a 78% efficiency
with either a-c or d-c input. A resistor and thyristor soft-start circuit limits start-up surge. Surface mount technology permits efficient component layout
for minimum mounting space. Six models may be selected for outputs of 5, 12, 15, 24, 28, or 48V. "POWER OK" logic and a green "POWER OK" LED
are provided. A steel cover (Model CA 28) is available as an option. Output voltage may be adjusted with a trimmer accessible near the input-output
terminal strip (R65, see Figure 4, View "A"). When the input is cut off, the output is maintained for 15 milliseconds minimum. If the power supply shuts
down, it is then necessary to wait 90 seconds minimum (120V a-c input) or 120 seconds minimum (240V a-c input) before reconnecting the a-c input
power to turn on the unit again. EMI filtering meets FCC Class B (100 to120 Volts) rating and VDE 0871 Class B (220 to 240 Volts) rating. This page
contains specifications for each model of the FAW 150 Watt Series. Environmental specifications for each model are the same.
II — SPECIFICATIONS
The following specifications apply to FAW 150 Watt Series models. Other FAW Series models are also available; consult your Kepco representative for
their specifications.
MODEL
OUTPUT VOLTS, d-c (NOMINAL)
ADJUSTMENT RANGE
OUTPUT CURRENT (NOMINAL)
OUTPUT POWER (MAXIMUM)
source (typ)
RIPPLE
source (max)
AND
NOISE
switching (typ)
(mV p-p)
0-50°C
switching (max)
10-100% LOAD
spike noise (d-c—50MHz)
OVERVOLTAGE SETTING (25 °C, NOM. INPUT)
OVERCURRENT SETTING (25°C, NOM. INPUT)
Rectangular type characteristic
(1) Derates same as Ouptut Power.
(2) See power derating curve, Figure 1.
INPUT:
Voltage: 120V a-c/240V a-c nominal; Range 85-264V a-c; 105-370V d-c (polarity insensitive).
Frequency: Nominal 50-60 Hz; Range 47-440Hz (at 440Hz leakage current exceeds UL/VDE safety leakage standards).
Current (nominal output at rated load): @120V a-c rms: 3.0A typ., 3.5A max; @240V a-c rms: 1.5A typ., 2.0A max.
Initial Turn-on Surge: (one-half of first input cycle): @120V a-c rms, 25A max.; @240V a-c rms, 50A max. When the a-c input power is removed,
the soft start circuit requires 30 seconds recovery time before the a-c input power is reconnected.
Brownout Voltage: 80V a-c, 97V d-c.
Switching Frequency: 120KHz typical, nominal load.
STABILIZATION:
Source Effect: Range 85-132V a-c or 170-264V a-c, 1.0% typ.; 2.0% max.
Load Effect: Range 10%-100% load, 1.0% typ.; 2.0% max.
Temperature Effect: Range 0
Combined Effect: 2.0% typ.; 4.0% max. (includes source, load, and temperature effects).
Time Effect: 0.1% typ.; 0.5% max. (1/2 hr-8 hr at 25
RECOVERY CHARACTERISTICS:
+1% of the original setting in <1 ms
START-UP TIME:
200 ms. maximum.
HOLD-UP TIME:
20 ms. typ. (120V a-c), 15 ms. min (100V a-c).
KEPCO, INC. !"! 131-38 SANFORD AVENUE !" FLUSHING, NY. 11352 U.S.A.!!" TEL (718) 461-7000!!" ! FAX (718) 767-1102!!
©1996, KEPCO, INC
Data subject to change without notice
An ISO 9001 Company.
KEPCO SINGLE OUTPUT 150 WATT
TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, FAW 150W SERIES
FAW 5-30K
5V
4.5 - 5.5V
(1 )
30A
(2 )
150W
10
20
30
60
<120
6.0-6.9V
32.0 - 36.0A
o
o
to 50
C, 1.0% typ.; 2.0% max.
o
C).
A step load change from 50% to 100% produces less than +4% output excursion. Recovery occurs to within
(t
or t
equal to or greater than 50
r
f
http://www.kepcopower.com " ! email: hq@kepcopower.com
FAW 12-12K
FAW 15-10K
12V
15V
10.8 - 13.2V
13.5 - 16.5V
12A
10A
144W
150W
15
15
30
40
35
40
70
80
<190
<220
13.7-15.7V
17.0-19.0V
13.0 - 15.0A
11.0 - 13.0A
µ
sec at load change).
228-1159
FAW
FAW 24-6K
FAW28-5K
24V
28V
21.6 - 26.4V
25.2 - 30.8V
6A
5A
144W
140W
15
20
40
40
50
60
110
140
<310
<330
27.0-30.5V
32.0-35.0
6.3 - 7.5A
5.3 - 6.1A
FAW 48-2.8K
48V
38.4 - 52.8V
2.8A
134.4W
20
40
80
220
<530
53.5-60.0
3.0 - 3.5A
1

Advertisement

loading

Summary of Contents for KEPCO FAW 5-30K

  • Page 1 I — INTRODUCTION The Kepco FAW 150 Watt Series low profile high frequency switching power supplies employ forward conversion and operate with a 78% efficiency with either a-c or d-c input. A resistor and thyristor soft-start circuit limits start-up surge. Surface mount technology permits efficient component layout for minimum mounting space.
  • Page 2 (+) and (–) output terminals, either at the load or at the Power Supply output terminals. The connection ensures the most accurate error tracking. Error compensation in the connecting wires is up to 0.25 Volts for the FAW 5-30K model, and up to 0.4 Volts for all other models.
  • Page 3 FIGURE 2. “POWER OK” SIGNAL RELATED TO OUTPUT AMBIENT TEMPERATURE FIGURE 3. LOAD CONNECTIONS WITH ERROR SENSING KEPCO, INC. !"! 131-38 SANFORD AVENUE !" FLUSHING, NY. 11352 U.S.A.!!" TEL (718) 461-7000!!" ! FAX (718) 767-1102! http://www.kepcopower.com " ! email: hq@kepcopower.com 062599...
  • Page 4 FIGURE 4. MECHANICAL OUTLINE DRAWING KEPCO, INC. !"! 131-38 SANFORD AVENUE !" FLUSHING, NY. 11352 U.S.A.!!" TEL (718) 461-7000!!" ! FAX (718) 767-1102!! http://www.kepcopower.com " ! email: hq@kepcopower.com 228-1159 062599 CM18672...

This manual is also suitable for:

Faw 15-10kFaw28-5kFaw 12-12kFaw 24-6kFaw 48-2.8k