Download Print this page
Lutron Electronics CONNECT-BDG-1 Installation Instructions Manual
Lutron Electronics CONNECT-BDG-1 Installation Instructions Manual

Lutron Electronics CONNECT-BDG-1 Installation Instructions Manual

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

Quick Links

Lutron Connect
Bridge
English
TM
Installation Instructions
CONNECT-BDG-1
041531b
02/2016
CONNECT-BDG-2
Lutron Connect
TM
DC Power Adapter
Bridge
T-5DC-USB-WH (included):
CONNECT-BDG-1
Input: 100 – 240 V~ 50/60 Hz 100 mA;
(5 V- 300 mA)
Output: 5 V- 550 mA
Not included. Use LPS or SELV output
CONNECT-BDG-2
5 V- 550–1000 mA USB Micro
(5 V- 300 mA)
Connector
Typical Power Consumption*: 1.3 W
Please Read Before Installing
Use these instructions to install the model numbers
listed above.
For more information visit: www.lutron.com/radiora2
or www.lutron.com/hwqs
Features
• Add button allows the bridge to be activated in a
RadioRA
2 or HomeWorks
QS system and the
®
®
Lutron Connect
Mobile App.
TM
• Ethernet port allows the bridge to be connected to a
wireless router.
Important Notes
Environment
Ambient operating temperature: 32 °F to 104 °F
(0 °C to 40 °C), 0% to 90% humidity. Indoor use only.
Codes
Install in accordance with all local and national
electrical codes.
Cleaning
To clean, wipe with a clean damp cloth. DO NOT use
any chemical cleaning solutions.
DC Power Adapter
Using a DC power adapter not rated at the proper
specifications could damage the Lutron Connect
and possibly overheat the DC power adapter. Ensure that
the DC power adapter follows the proper specifications
as detailed above.
Programming
Programming and activation (addressing) must be
accomplished through the RadioRA
2 or
®
HomeWorks
QS software.
®
* Typical Power Consumption test conditions: LED on, Ethernet cable
plugged in, powered by the 5 V- adapter.
Lutron Elec tron ics Co., Inc.
7200 Suter Road Coopersburg, PA 18036-1299
Dimensions
Measurements shown as: in (mm)
Top View
Ethernet
Cable
Included
Included
2.75
(69.9)
Front View
Status LED Bar
2.75
(69.9)
Connections
Back View
"Add" Button
bridge
TM
Power Jack (to adapter)
NEC
Class 2, LPS or SELV, limited energy (<15 W)
®
Ethernet CAT5 Port
Lutron, HomeWorks, and RadioRA are registered trademarks and RadioRA 2 and Lutron Connect are trademarks of Lutron Electronics Co., Inc.
NEC is a registered trademark of National Fire Protection Association, Quincy, Massachusetts. © 2016 Lutron Electronics Co., Inc.
Installation
1. Using the Ethernet cable, connect the Lutron Connect
bridge to a wireless router on the same network (subnet)
as the RadioRA
2 main repeater or the HomeWorks
®
processor.
2. Attach the DC power adapter cord to the power jack on
the Lutron Connect
bridge and insert the DC power
TM
adapter plug into a receptacle.
3. Use the RadioRA
2 or HomeWorks
®
to activate the Lutron Connect
Ensure convenient access to the "Add" button because it
will be used for activating the bridge into the system and
2.75
pairing with the Lutron Connect
(69.9)
4. Use the Lutron Connect
App to control and monitor the
TM
system through the Lutron Connect
button will be used for pairing the app to the bridge.
RadioRA
2 Main Repeater
®
DC Power
Lutron Connect
Bridge
Adapter
TM
USB
Main Repeater
Repeater Status
M
1
2
3
4
Communication
RF
Wired
Setup
Ethernet
Test
Add
RadioRA
2 Main Repeater
®
Connection
USB
Main Repeater
Power Repeater Link
Integrate
Program / Integrate
9 V
1
2
3
4
RS232
Ethernet
Repeater Status
M
1
2
3
4
Communication
1.19
RF
Wired
Setup
Test
Add
(30.2)
Power Repeater Link
Integrate
Program / Integrate
9 V
1
2
3
4
RS232
Ethernet
HomeWorks
QS Processor
®
DC Power
Lutron Connect
Bridge
Adapter
TM
Ethernet
Connection
24 V-
Input
HomeWorks
®
QS Processor
Ethernet
Connection
Status LED Bar Blink Codes
TM
Blink Pattern
5-second blink • No network cable connection.
QS
®
Rotating
QS design software
®
bridge into the system.
TM
Returning Lutron Connect
Factory Settings
App.
TM
Returning the Lutron Connect
settings will erase all its programming and will require
bridge. The "Add"
TM
the Lutron Connect
system.
1. Triple tap and hold the "Add" button. DO NOT release
the button after the third tap.
2. Keep the button pressed on the third tap until the
Lutron
LEDs start to flash.
Connect
TM
App
3. Release the button and immediately triple tap it again.
The LEDs will flash quickly. When the LEDs stop
flashing, the Lutron Connect
returned to its factory settings.
Wireless Router
(not sold by Lutron)
Ethernet
Connection
Warranty
For warranty information, please see the Warranty
Lutron
Connect
enclosed with the product, or visit
TM
App
www.lutron.com/resiinfo
FCC/IC Information
For FCC/IC information, please visit
www.lutron.com/fcc-ic
Customer Assistance
Online: forums.lutron.com | www.lutron.com/help
Wireless Router
(not sold by Lutron)
Email: support@lutron.com
Phone:
U.S.A./Canada: 1.844.LUTRON1 (588.7661)
Europe: +44.(0)20.7680.4481
Mexico: +1.888.235.2910
Other Countries: +1.610.282.3800
Indication
• Bridge firmware is updating if the status
LEDs are progressing around the bridge
in sequence.
• Firmware is updating. The Lutron
Connect
bridge is not functional during
TM
a firmware update.
Bridge to
TM
bridge to its factory
TM
bridge to be reactivated into the
TM
bridge has been
TM

Advertisement

loading

Summary of Contents for Lutron Electronics CONNECT-BDG-1

  • Page 1 Other Countries: +1.610.282.3800 plugged in, powered by the 5 V- adapter. Lutron, HomeWorks, and RadioRA are registered trademarks and RadioRA 2 and Lutron Connect are trademarks of Lutron Electronics Co., Inc. Lutron Elec tron ics Co., Inc. NEC is a registered trademark of National Fire Protection Association, Quincy, Massachusetts. © 2016 Lutron Electronics Co., Inc.
  • Page 2: Caractéristiques

    Autres pays : +1.610.282.3800 allumée, câble Ethernet branché, alimenté par l’adaptateur de 5 V-. Lutron, HomeWorks, et RadioRA sont des marques déposées, et RadioRA 2 et Connect de Lutron sont des marques commerciales de Lutron Electronics Co., Inc. Lutron Electronics Co., Inc.
  • Page 3: Instalación

    Otros países: +1.610.282.3800 cable de Ethernet enchufado, alimentado por el adaptador de 5 V-. Lutron, HomeWorks y RadioRA son marcas comerciales registradas y RadioRA 2 y Lutron Connect son marcas comerciales de Lutron Electronics Co., Inc. Lutron Elec tron ics Co., Inc.
  • Page 4 5 V-. Outros países: +1.610.282.3800 Lutron, HomeWorks e RadioRA são marcas comerciais registradas, e RadioRA 2 e Lutron Connect são marcas comerciais da Lutron Electronics Co., Inc. Lutron Electronics Co., Inc. NEC é marca comercial registrada da National Fire Protection Association, de Quincy, Massachusetts, EUA. © 2016 Lutron Electronics Co., Inc.
  • Page 5 Sonstige Länder: +1.610.282.3800 angeschlossen, Speisung über den 5-V--Adapter. Lutron, HomeWorks und RadioRA sind eingetragene Marken und RadioRA 2 und Lutron Connect sind Marken von Lutron Electronics Co., Inc. Lutron Electronics Co., Inc. NEC ist eine eingetragene Marke der National Fire Protection Association, Quincy, Massachusetts (USA). © 2016 Lutron Electronics Co., Inc.
  • Page 6 其他国家:+1.610.282.3800 由 5 V- 适配器供电。 Lutron Elec tron ics Co., Inc. Lutron、 HomeWorks 和 RadioRA 是注册商标, RadioRA 2 和Lutron Connect 是 Lutron Electronics Co., Inc. 的商标。 7200 Suter Road Coopersburg, PA 18036-1299 NEC 是马萨诸塞州昆西美国国家消防协会的注册商标。 © 2016 Lutron Electronics Co., Inc.

This manual is also suitable for:

Connect-bdg-2