C SERIES USER'S MANUAL

6.4.8 Repeat Function

Each time after finish working, switch the cutter into offline status and press Repeat. The cutter
will repeat the job done last time.
Hints: The main board load in flash memory, so it can not repeat the last job after the cutter
switch on again. What's more, the flash memory is limited; the data shall not larger than the
buffer memory. If the data is too large, it can not repeat the job as well. The LCD will display
No data. Shown as followings:

6.4.9 Port Setting

Press Menu and enter into menu setting, Us refers to idle speed( default parameter Us=600mm),
it can increase the carriage moving speed while it will not cutting. Press once the idle speed will
increase/decrease by 50mm/s. Br refers to baud rate( default parameter Br=38400), there're six
baud rates: 57600, 38400, 28800, 19200, 14400 and 9600. The baud rate setting must be the
same as computer's communication port in use baud rate's setting. The default parameter when
turn on the cutter is 38400. Shown as followings: