CAUTION: READ INSTALLATION / OPERATION INSTRUCTIONS PRIOR TO INSTALLING AND OPERATING THE FRESHSTART BREWER INSTALLATION INSTRUCTIONS A. INSPECTION Brewer comes complete with brew basket, detachable power cord and installation/operation manual (carafe may be included, but is sold separately). Inspect the carton and brewer for evidence of rough handling and concealed damage. Damage claims should be filed with the carrier.
Page 3
WARNING: WATER TANK MUST BE FILLED BEFORE PLUGGING MACHINE INTO ELECTICAL OUTLET VOLUME PROGRAM PROCEDURE A. ENERGIZE BREWER / HOT TANK HEAT UP To power up brewer and start the hot tank, push the ON/OFF MAIN POWER switch, at rear of the brewer, to the ON position (See Figure 2).
OPERATION INSTRUCTIONS A. BREWING COFFEE Remove brew basket from brewer. Place one (1) standard commercial filter (9.5 inch diameter) into brew basket. Put required amount of coffee grounds into filter and shake brew basket to level off coffee grounds. Return brew basket to brewer. NOTE: Brew basket is designed to click into Filter/Coffee...
SERVICE INSTRUCTIONS A. ADJUSTING HOT TANK THERMOSTAT Rear Switch Plate Screws (2) Whenever thermostat adjustment becomes On/Off main necessary, complete the following procedure: 3/8” Quick Tube power switch Disconnect power cord from electrical Connect IEC Cord outlet. Receptacle Remove (2) screws and rear panel (see Thermostat figure 5).
SERVICING THE MECHANICAL FLOATS Air filter Resetting the Safety Float Remove cover from cabinet. Press down on the safety float Safety float re-set button (see figure 8). re-set button Circuit Board Float arm inspection Remove float cap from top Solenoid Valve reservoir.
Page 7
G. THERMOSTAT REPLACEMENT (CONTINUED) Limiter Control (see figure 11) Follow steps 1 and 2 from Primary Thermostat. Remove tank feed and vent silicone tubing from reservoir bottom. Remove upper reservoir by releasing the (3) clips. Remove both wires from limiter thermostat. Using a ¼...
TROUBLE SHOOTING GUIDE PROBLEM RESOLUTION • Brew Cycle Will Not Start Check that the power cord is properly plugged into the IEC receptacle located at the back of the brewer (see Figure 5). • Check that the power cord is plugged into a proper electrical outlet (see Service Instructions Section C).