Download Print this page

ACESEE IMX222+DM368 Quick Operation Manual

Ti 2mp ip camera

Advertisement

Quick Links

HD IP CAMERA
Quick Operation Guide
IMX222+DM368
Thank you for using our product, please read this manual
carefully before use.
Please refer to the complete User manual for more information
from the CD.
1
Unpacking Inspection
1. Once receive the product, the user should open the
outer packing box to check the appearance for obvious
damage.
2. Please referring to the following list to check whether
the accessories are complete.
|Accessories list
Accessory name
Number
IP camera
1
1
CD(users guide)
Quick Operation Guide
1
Mind you respected user, important
operations and maintenance (repair)
guide are described in the attached
product instruction.
Mind you respected user, uninsulated
"dangerous voltage" exists, please be
aware of electric shock.
2
Product Notes
Thank you for buying our IP camera, please read
the following instructions carefully to learn the
related operation.
1. Before using the camera,please read this
guide book carefully and make sure the power
supply is normal.
2. Users should follow the manufacturer's instruc-
tions to install device professionally and must
not dismantle the equipment without permission.
3. To prevent the sensor pull light phenomenon,
prohibit putting the lens under bright light for a
long time.
4. If the lens is dirty or foggy, please use a dry soft
cloth to clean it.
5. The equipment must not be installed under the
air door of air conditioner , otherwise the lens
will become blurry and condenses into moisture.
6. When install, repair or clean the equipment,
please make sure the power has been turned
off.
7. Stay away from high temperature and heat
source environment, pay attention to ventilation.
8. To avoid damage and electrical shock, non-
professionals are forbidden to dismantle the
equipment.
9. Prohibit putting this equipment to work in strong
magnetic field and laser beam environment.
10. If there is lightning during installation, please
take grounding lightning protection measures.
11. Damages to the machine and all other
economic losses caused by human are at
your own risk.
Reminders:
Power supply must pass safety certification ,Its
output voltage, current, voltage polarity and oper-
ating temper ature must match requirement of this
equipment.
• Please install lightning protection devices or cut off
the power in thunder and lightning conditions.
• To capture high-quality video and pictures, please
make sure the network connection is stable and
smooth.
3
Main Features
1. Ultra-low illumination and high-performance real-time
screen, support ABLC image effect.
2. Support WEB configuration, and IE network Monitoring
3. Support dual-stream.
4. Support OSD, color, brightness, saturation and digital
zoom settings settings.
5. Support real-time video transmission, video motion
detection and privacy masking.
6. Support remote monitoring, ONVIF2.4 protocol and
IR-CUT switch.
7. Support P2P network platform.
4
Parameter Description
Name
IMX222+DM368
Description
TI 2MP IP camera
Sensor type
1/2.8" 2.43 Megapixel CMOS Image sensor.
Minimum Illumination
0.5 Lux
S/N Ratio
˃50db
Shutter
1—1/10000s(adjustable)
2.8mm/3.6mm/4mm/6mm/8mm/2.8-12mm
Lens
(adjustable),Lens optional
Lens interface type
C/CS
Day/Night
ICR-infrared filter
Video Compression
H.264/JPEG
Bit Rate
64-12000Kbps
Max image size
1920×1080
50Hz:25fps(1920×1080)
Frame Rate
60Hz:30fps(1920×1080)
Brightness, contrast, saturation, sharpness
Image setting
can be adjusted
Backlight Compensation
Support
Storage function
FTP、Local、NVR、SMTP
Onvif
Onvif 2.4
Intelligent alarm
Motion detection、Privacy
TCP/IP、HTTP、DHCP、FTP、DNS、
Protocol
DDNS、RTSP、NTP、SMTP
General function
Single/Dual/Tri-Stream/Mirror
Communication inter-
RJ45(10M/100M)Adaptive Ethernet port
face
Temperature
-20℃~55℃
Humidity
0%-90%RH Without Condensation
Power
DC12V±5% / PoE(802.3af)
Size
38×38mm
5
Camera Structure
Illustration
The following structure diagram is used as an example
for the different appearances of different models.
1. Input interface
External camera structure diagram
Type1
Type2
Sequence NO.
Interface
Functional description
1
Power connector
12V DC input power
2
Network interface
Network data transmission
Power connector(for
3
12V DC input power
stand-by power)
Network data transmission ,
4
Network interface
12V DC input power
2. Device connection
PC

Advertisement

loading

Summary of Contents for ACESEE IMX222+DM368

  • Page 1 Quick Operation Guide supply is normal. 4. Support OSD, color, brightness, saturation and digital IMX222+DM368 zoom settings settings. 2. Users should follow the manufacturer's instruc- tions to install device professionally and must 5.
  • Page 2 Quick Configuration Tool Computer Client Connection 1. Install Computer Client Software CMS ※ Add device manually: Configuration→Device Management →Add Manually Find out the document “HeroSpeedCMS.exe”, 1.Install Client Software make a copy in your computer and double click to install it . Find out the document“IP Search.exe”, 2.Search Add Device make a copy in the computer and double...

This manual is also suitable for:

Ov9712s+hi3518c