Sign In
Upload
Manuals
Brands
Siemens Manuals
Accessories
Brodersen MC55
Siemens Brodersen MC55 Manuals
Manuals and User Guides for Siemens Brodersen MC55. We have
2
Siemens Brodersen MC55 manuals available for free PDF download: Command Manual, Command Set
Siemens Brodersen MC55 Command Manual (475 pages)
AT Command Manual
Brand:
Siemens
| Category:
Modem
| Size: 3.4 MB
Table of Contents
Table of Contents
3
1 Introduction
13
Scope of the Document
13
Related Documents
14
Document Conventions
15
Quick Reference Table
15
Superscript Notation for Parameters and Values
16
Table 1.1: Symbols Used to Mark the Type of Parameters
16
Table 1.2: Symbols Used to Indicate the Correlations with Other Commands
16
Table 1.3: Symbols Used to Mark Different Types of Default Values of Parameters
16
AT Command Syntax
17
Using Parameters
17
Table 1.4: Types of at Commands and Responses
17
Combining at Commands on the same Command Line
18
Supported Character Sets
19
Table 1.5: Examples for Character Definitions Depending on Alphabet
20
Figure 1.1: Main Character Table of GSM 03.38 Alphabet
21
GSM Alphabet Tables and UCS2 Character Values
21
Figure 1.2: Extension Character Table of GSM 03.38 Alphabet
22
Implementing Output of SIM Data to Terminal (Direction TA to TE)
23
UCS2 and GSM Data Coding and Conversion for SMS Text Mode
23
Implementing Input of Terminal Data to SIM (Direction te to TA)
24
Serial Interface Flow Control
25
Software Flow Control (XON/OFF Handshake)
25
Hardware Flow Control (RTS/CTS Handshake)
25
Unsolicited Result Code Presentation
26
Communication between Customer Application and MC55
26
Common PCN Handset Specification (CPHS)
27
Errors and Messages
28
2 Configuration Commands
29
AT&F Set All Current Parameters to Manufacturer Defaults
29
AT&V Display Current Configuration
30
AT&V Responses
31
Table 2.1: Current Configuration on ASC0 / MUX Channel 1 (Example)
31
Table 2.2: Current Configuration on ASC1 and MUX Channels 2 and 3 (Example)
31
AT&W Stores Current Configuration to User Defined Profile
32
ATQ Set Result Code Presentation Mode
33
ATV Set Result Code Format Mode
34
Verbose and Numeric Result Codes
34
ATX Set CONNECT Result Code Format and Call Monitoring
35
ATZ Set All Current Parameters to User Defined Profile
36
AT+CFUN Set Phone Functionality
37
Parameter Description
38
Table 2.3: Wake-Up Events in NON-CYCLIC and CYCLIC SLEEP Modes
40
Wake up the ME from SLEEP Mode
40
AT^SMSO Switch off Mobile Station
42
AT+GCAP Request Complete TA Capabilities List
43
AT+CMEE Mobile Equipment Error Message Format
44
CME/CMS Error Code Overview
45
Table 2.4: General "CME ERROR" Codes (GSM 07.07)
45
Table 2.5: General "CME ERROR" Codes (SIEMENS)
46
Table 2.6: GPRS Related "CME ERROR" Codes (GSM 07.07)
46
Table 2.7: SMS Related "CMS ERROR" Codes (GSM 07.05)
46
AT+CSCS Select te Character Set
49
AT^SCFG Extended Configuration Settings
50
AT^SM20 Set M20 Compatibility Mode
59
3 Status Control Commands
60
AT+CMER Mobile Equipment Event Reporting
60
AT+CIND Indicator Control
62
AT^SIND Extended Indicator Control
65
AT+CEER Extended Error Report
71
Cause Location ID for the Extended Error Report
72
GSM Release Cause for L3 Radio Resource (RR)
73
SIEMENS Release Cause for L3 Radio Resource (RR)
73
GSM Release Cause for Mobility Management (MM) or Session Management (SM)
74
SIEMENS Release Cause for L3 Mobility Management (MM)
75
GSM Release Cause for L3 Call Control (CC)
75
SIEMENS Release Cause for L3 Call Control (CC)
77
SIEMENS Release Cause for L3 Advice of Charge (AOC)
77
GSM Release Cause for Supplementary Service Call
77
SIEMENS Release Cause for Call-Related Supplementary Services (CRSS)
79
SIEMENS Release Cause for Session Management (SM)
80
GSM Cause for L3 Protocol Module or Other Local Cause
80
SIEMENS Release Cause for GPRS API
80
SIEMENS Release Cause for PPP/IP-Stack
80
ATS18 Extended Call Release Report
81
AT+CPAS Mobile Equipment Activity Status
83
AT+WS46 Select Wireless Network
84
4 Serial Interface Control Commands
85
AT\Q Flow Control
85
AT&C Set Data Carrier Detect (DCD) Line Mode
86
AT&D Set Circuit Data Terminal Ready (DTR) Function Mode
87
AT&S Set Circuit Data Set Ready (DSR) Function Mode
88
ATE Enable Command Echo
89
AT+ILRR Set TE-TA Local Rate Reporting
90
AT+IPR Set Fixed Local Rate
92
Autobauding
93
AT+CMUX Enter Multiplex Mode
95
Restrictions on Multiplex Mode
96
Table 4.1: Availability of at Commands on Virtual Channels
96
Table 4.2: Summary of at Commands with Different Behavior in Multiplex Mode
97
Second Serial Interface ASC1
98
5 Security Commands
99
AT+CPIN PIN Authentication
99
What to Do if PIN or Password Authentication Fails
101
AT+CPIN2 PIN2 Authentication
103
AT^SPIC Display PIN Counter
105
AT+CLCK Facility Lock
109
AT^SLCK Facility Lock
114
AT+CPWD Change Password
115
AT^SPWD Change Password
119
6 Identification Commands
120
ATI Display Product Identification Information
120
AT+CGMI Request Manufacturer Identification
121
AT+GMI Request Manufacturer Identification
121
AT+CGMM Request Model Identification
122
AT+GMM Request Model Identification
122
AT+CGMR Request Revision Identification of Software Status
123
AT+GMR Request Revision Identification of Software Status
123
AT+CGSN Request International Mobile Equipment Identity (IMEI)
124
AT+GSN Request International Mobile Equipment Identity (IMEI)
124
AT+CIMI Request International Mobile Subscriber Identity (IMSI)
125
7 Call Related Commands
126
Call Status Information
126
ATA Answer a Call
127
ATD Mobile Originated Call to Specified Number
128
Atd><Mem><N> Mobile Originated Call Using Specific Memory and Index Number
130
Atd><N> Mobile Originated Call from Active Memory Using Index Number
132
Atd><Str> Mobile Originated Call from Active Memory Using Corresponding Field
133
ATDI Mobile Originated Call to ISDN Number
134
ATDL Redial Last Number Used
135
ATH Disconnect Existing Connection
136
AT+CHUP Hang up Call
137
ATS0 Set Number of Rings before Automatically Answering a Call
138
ATS6 Set Pause before Blind Dialing
139
ATS7 Set Number of Seconds to Wait for Connection Completion
140
ATS8 Set Number of Seconds to Wait for Comma Dialing Modifier
141
ATS10 Set Disconnect Delay after Indicating the Absence of Data Carrier
142
ATO Switch from Command Mode to Data Mode / PPP Online Mode
143
Switch from Data Mode to Command Mode
144
AT+CBST Select Bearer Service Type
145
AT+CRLP Select Radio Link Protocol Parameters for Originated Non-Transparent Data Calls
146
AT+CLCC List Current Calls of ME
147
AT^SLCC Siemens Defined Command to List Current Calls of ME
149
AT+CR Service Reporting Control
155
AT+CRC Set Cellular Result Codes for Incoming Call Indication
156
AT+CSNS Single Numbering Scheme
157
AT^SCNI List Call Number Information
158
AT^SLCD Display Last Call Duration
159
AT^STCD Display Total Call Duration
160
ATP Select Pulse Dialing
161
ATT Select Tone Dialing
161
8 Network Service Commands
162
AT+COPN Read Operator Names
162
AT+COPS Operator Selection
163
AT^SOPS Extended Operator Selection
166
AT+CREG Network Registration
168
AT+CSQ Signal Quality
171
AT^SMONC Cell Monitoring
172
AT^SMOND Cell Monitoring
174
AT^MONI Monitor Idle Mode and Dedicated Mode
177
AT^MONI Responses
178
Service States
179
AT^MONP Monitor Neighbour Cells
180
AT^MONP Responses
181
AT^SMONG GPRS Monitor
182
AT^SMONG Cell Info Table
183
AT^SALS Alternate Line Service
184
AT^SHOM Display Homezone
186
AT^SPLM Read the PLMN List
187
AT+CPOL Preferred Operator List
188
AT^SPLR Read Entry from the Preferred Operators List
189
AT^SPLW Write an Entry to the Preferred Operators List
190
9 Supplementary Service Commands
191
AT+CACM Accumulated Call Meter (ACM) Reset or Query
191
AT^SACM Advice of Charge and Query of ACM and Acmmax
192
AT+CAMM Accumulated Call Meter Maximum (Acmmax) Set or Query
194
AT+CAOC Advice of Charge Information
195
AT+CCUG Closed User Group
196
AT+CCFC Call Forwarding Number and Conditions Control
198
AT+CCWA Call Waiting
202
AT+CHLD Call Hold and Multiparty
206
AT+CLIP Calling Line Identification Presentation
208
AT+CLIR Calling Line Identification Restriction
210
AT+COLP Connected Line Identification Presentation
211
AT+CPUC Price Per Unit and Currency Table
213
AT+CSSN Supplementary Service Notifications
215
AT+CUSD Supplementary Service Notifications
217
10 Internet Service Commands
219
AT^SICS Internet Connection Setup Profile
222
Table 10.1: Applicability of AT^SICS <Conparmtag> Values
222
Example: Default Values of a CSD Connection Profile
224
Example: GPRS Connection Profile
225
AT^SICI Internet Connection Information
226
Checking Connection Profile Status
227
AT^SISS Internet Service Setup Profile
228
Table 10.2: Applicability of AT^SISS <Srvparmtag> Values
228
AT^SISI Internet Service Information
237
AT^SISO Internet Service Open
239
Example: Accepting / Rejecting Socket Connection Request from Remote Client
242
AT^SISC Internet Service Close
244
AT^SISR Internet Service Read Data
245
Example: Socket Host Reads Small Amounts of UDP Data Packets (URC Mode)
246
AT^SISW Internet Service Write Data
248
Usage of Parameter <Eodflag
250
AT^SISE Internet Service Error Report
251
Internet Service URC "^SIS
252
Information Elements Related to the Service Application
253
Information Elements Related to FTP Service
254
Information Elements Related to HTTP Service
255
Information Elements Related to POP3 Service
255
Information Elements Related to SMTP Service
255
Examples of How to Configure and Use Internet Service Profiles
256
Selecting URC Mode or Polling Mode
256
Configuring Socket Listener
256
Configuring Socket Client for Calling a Socket Listener on Another Host
257
Socket Client Sends Data Via TCP Connection (Polling Mode)
257
Socket Client Sends Data Via TCP Connection with Urcs
258
Configuring and Using FTP Download (URC Mode)
258
Configuring and Using FTP Upload (URC Mode)
259
Configuring SMPT Service Profile
259
Sending Email (URC Mode)
260
Sending Email (Polling Mode)
261
Configuring POP3 Service Profile
262
Retrieving Email (URC Mode)
262
Retrieving Email (Polling Mode)
263
HTTP POST (Polling Mode)
264
HTTP GET (Polling Mode)
265
11 GPRS Commands
266
AT+CGACT PDP Context Activate or Deactivate
266
AT+CGANS Manual Response to a Network Request for PDP Context Activation
268
AT+CGATT GPRS Attach or Detach
270
AT+CGAUTO Automatic Response to a Network Request for PDP Context Activation
271
AT+CGEREP GPRS Event Reporting
273
AT+CGDATA Enter Data State
275
Automatic Deactivation of PDP Context During Dial-Up PPP
276
AT+CGDCONT Define PDP Context
277
AT+CGPADDR Show PDP Address
279
AT+CGQMIN Quality of Service Profile (Minimum Acceptable)
280
AT+CGQREQ Quality of Service Profile (Requested)
284
AT+CGREG GPRS Network Registration Status
288
AT+CGSMS Select Service for MO SMS Messages
290
AT^SGAUTH Set Type of Authentication for PPP Connection
291
AT^SGCONF Configuration of GPRS Related Parameters
292
ATA Manual Response to a Network Request for PDP Context Activation
293
ATD*99# Request GPRS Service
294
ATD*98# Request GPRS IP Service
295
ATH Manual Rejection of a Network Request for PDP Context Activation
296
ATS0 Automatic Response to a Network Request for PDP Context Activation
297
Using GPRS at Commands (Examples)
298
Using the GPRS Dial Command ATD
300
12 FAX Commands
301
FAX Parameters
301
Summary of Fax Class 2 Urcs Defined by EIA PN-2388
303
Table 12.1: Summary of Fax Class 2 Urcs Defined by EIA PN-2388
303
AT+FBADLIN Bad Line Threshold
304
AT+FBADMUL Error Threshold Multiplier
305
AT+FBOR Query Data Bit Order
306
AT+FCIG Query or Set the Local Polling ID
307
AT+FCLASS Fax: Select, Read or Test Service Class
308
AT+FCQ Copy Quality Checking
309
AT+FCR Capability to Receive
310
AT+FDCC Query or Set Capabilities
311
AT+FDFFC Data Compression Format Conversion
312
AT+FDIS Query or Set Session Parameters
313
AT+FDR Begin or Continue Phase C Data Reception
314
AT+FDT Data Transmission
315
AT+FET End a Page or Document
316
AT+FK Kill Operation, Orderly FAX Abort
317
AT+FLID Query or Set the Local ID Setting Capabilities
318
AT+FMDL Identify Product Model
319
AT+FMFR Request Manufacturer Identification
320
AT+FOPT Set Bit Order Independently
321
AT+FPHCTO DTE Phase C Response Timeout
322
AT+FREV Identify Product Revision
323
AT+FRH Receive Data Using HDLC Framing
324
AT+FRM Receive Data
325
AT+FRS Receive Silence
326
AT+FTH Transmit Data Using HDLC Framing
327
AT+FTM Transmit Data
328
AT+FTS Stop Transmission and Wait
329
AT+FVRFC Vertical Resolution Format Conversion
330
13 Short Message Service (SMS) Commands
331
SMS Parameters
331
AT+CMGC Send an SMS Command
335
AT+CMGD Delete Short Message
336
AT+CMGF Select SMS Message Format
337
AT+CMGL List SMS Messages from Preferred Store
338
AT+CMGR Read SMS Messages
340
AT+CMGS Send Short Message
342
AT+CMGW Write Short Messages to Memory
344
AT+CMSS Send Short Messages from Storage
346
AT+CNMA New Message Acknowledgement to ME/TE, Only Phase 2
347
AT+CNMI New Short Message Indication
348
AT+CPMS Preferred SMS Message Storage
351
AT+CSCA SMS Service Center Address
353
AT+CSCB Select Cell Broadcast Message Indication
354
AT+CSDH Show SMS Text Mode Parameters
355
AT+CSMP Set SMS Text Mode Parameters
356
AT+CSMS Select Message Service
358
AT^SLMS List SMS Memory Storage
360
AT^SMGL List Short Messages from Preferred Store Without Setting Status to REC READ
361
AT^SMGO Set or Query SMS Overflow Presentation Mode or Query SMS Overflow
362
AT^SMGR Read Short Message Without Setting Status to REC READ
364
AT^SSCONF SMS Command Configuration
365
AT^SSDA Set SMS Display Availability
366
AT^SSMSS Set Short Message Storage Sequence
367
14 SIM Related Commands
368
AT+CRSM Restricted SIM Access
368
AT^SXSM Extended SIM Access
370
AT^SCKS Query SIM and Chip Card Holder Status
372
AT^SCID Display SIM Card Identification Number
374
AT+CXXCID Display Card ID
375
15 SIM Application Toolkit (SAT) Commands
376
AT^SSTA SAT Interface Activation
376
SSTN SAT Notification
378
AT^SSTGI SAT Get Information
379
AT^SSTR SAT Response
380
16 Phonebook Commands
381
Sort Order for Phonebooks
381
AT+CPBR Read from Phonebook
382
AT+CPBS Select Phonebook Memory Storage
385
AT+CPBW Write into Phonebook
387
AT^SPBC Find First Matching Entry in Sorted Phonebook
390
AT^SPBD Purge Phonebook Memory Storage
391
AT^SPBG Display Phonebook Entries in Alphabetical Order
392
AT^SPBS Step through the Selected Phonebook Alphabetically
395
AT+CNUM Read Own Numbers
399
AT^SDLD Delete the 'Last Number Redial' Memory
400
17 Audio Commands
401
Audio Programming Model
401
Figure 17.1: Audio Programming Model for MC55 Module
401
ATL Set Monitor Speaker Loudness
402
ATM Set Monitor Speaker Mode
402
AT+CLVL Loudspeaker Volume Level
403
AT+CMUT Mute Control
404
AT+VTD Tone Duration
405
AT+VTS DTMF and Tone Generation
406
AT^SAIC Audio Interface Configuration
407
AT^SNFA Set or Query of Microphone Attenuation
409
AT^SNFD Set Audio Parameters to Manufacturer Default Values
411
AT^SNFI Set Microphone Path Parameters
412
AT^SNFM Set Microphone Audio Path and Power Supply
413
AT^SNFO Set Audio Output (= Loudspeaker Path) Parameter
415
AT^SNFPT Set Progress Tones
417
AT^SNFS Select Audio Hardware Set
418
AT^SNFTTY Signal TTY/CTM Audio Mode Capability
421
AT^SNFV Set Loudspeaker Volume
422
AT^SNFW Write Audio Setting in Non-Volatile Store
423
AT^SRTC Ring Tone Configuration
424
18 Hardware Related Commands
426
AT+CCLK Real Time Clock
426
AT+CALA Set Alarm Time
427
AT^SBC Battery Charge Control
430
Responses Returned by Read Command
432
AT^SBV Battery/Supply Voltage
433
AT^SCTM Set Critical Operating Temperature Presentation Mode or Query Temperature
434
AT^SSYNC Configure SYNC Pin
437
ME Status Indicated by Status LED Patterns
438
Table 18.1: Modes of the LED and Indicated ME Functions
438
19 Miscellaneous Commands
439
A/ Repeat Previous Command Line
439
ATS3 Set Command Line Termination Character
440
ATS4 Set Response Formatting Character
441
ATS5 Write Command Line Editing Character
442
20 Appendix
443
Restricted Access to SIM Data after SIM PIN Authentication
443
Star-Hash (*#) Network Commands
444
Table 20.1: Star-Hash (*#) Command Overview
444
Table 20.2: Abbreviations of Codes and Parameters Used in Table
445
Table 20.3: Star-Hash Command Response Parameters
446
Table 20.4: Star-Hash Commands for Supplementary Services
446
Available at Commands and Dependency on SIM PIN
447
Table 20.5: Available at Commands and Dependency on SIM PIN
447
Availability of at Commands Depending on Operating Mode of ME
454
Table 20.6: Availability of at Commands Depending on Operating Mode of ME
454
AT Command Settings Storable with AT&W
461
Table 20.7: Settings Stored to User Profile on ASC0 / MUX Channel 1
461
Table 20.8: Settings Stored to User Profile on ASC1 / MUX Channels 2 and 3
462
Factory Default Settings Restorable with AT&F
464
Table 20.9: Factory Default Settings Restorable with AT&F
464
Summary of Unsolicited Result Codes (URC)
467
Table 20.10: Summary of Unsolicited Result Codes (URC)
467
Alphabetical List of at Commands
470
Table 20.11: Alphabetical List of at Commands
470
Advertisement
Siemens Brodersen MC55 Command Set (469 pages)
Brand:
Siemens
| Category:
Accessories
| Size: 3.05 MB
Table of Contents
Table of Contents
3
List of Figures
12
1 Introduction
13
Scope of the Document
13
Related Documents
14
Document Conventions
15
Quick Reference Table
15
Superscript Notation for Parameters and Values
16
Table 1.1: Symbols Used to Indicate the Correlations with Other Commands
16
Table 1.2: Symbols Used to Mark Different Types of Default Values of Parameters
16
AT Command Syntax
17
Using Parameters
17
Combining at Commands on the same Command Line
18
Supported Character Sets
19
GSM Alphabet Tables and UCS2 Character Values
21
Figure 1.1: Main Character Table of GSM 03.38 Alphabet
21
Figure 1.2: Extension Character Table of GSM 03.38 Alphabet
22
UCS2 and GSM Data Coding and Conversion for SMS Text Mode
23
Implementing Output of SIM Data to the te (Direction ME to TE)
23
Implementing Input of Terminal Data to SIM (Direction te to ME)
24
Flow Control
26
Software Flow Control (XON/OFF Flow Control)
26
Hardware Flow Control (RTS/CTS Flow Control)
26
Unsolicited Result Code Presentation
27
Communication between Customer Application and MC55
27
Common PCN Handset Specification (CPHS)
28
Errors and Messages
29
2 Configuration Commands
30
AT&F Set All Current Parameters to Manufacturer Defaults
30
AT&V Display Current Configuration
31
AT&V Responses
31
Table 2.1: Current Configuration on ASC0 / MUX Channel 1 (Example)
32
Table 2.2: Current Configuration on ASC1 and MUX Channels 2 and 3 (Example)
32
AT&W Stores Current Configuration to User Defined Profile
33
ATQ Set Result Code Presentation Mode
34
ATV Set Result Code Format Mode
35
Verbose and Numeric Result Codes
35
ATX Set CONNECT Result Code Format and Call Monitoring
37
ATZ Set All Current Parameters to User Defined Profile
38
AT+CFUN Set Phone Functionality
39
Wake up the ME from SLEEP Mode
43
Table 2.3: Wake-Up Events in NON-CYCLIC and CYCLIC SLEEP Modes
43
AT^SMSO Switch off Mobile Station
44
AT+GCAP Request Complete TA Capabilities List
45
AT+CMEE Report Mobile Equipment Error
46
Summary of CME ERRORS Related to GSM 07.07
47
Summary of GPRS-Related CME ERRORS
48
Summary of CMS ERRORS Related to GSM 07.05
49
AT+CSCS Select te Character Set
52
AT^SCFG Extended Configuration Setting
54
Parameter Description
57
AT^SM20 Set M20 Compatibility Mode
61
3 Status Control Commands
63
AT+CMER Mobile Equipment Event Reporting
63
AT+CIND Indicator Control
66
AT^SIND Extended Indicator Control
70
AT+CEER Extended Error Report
73
Cause Location ID for the Extended Error Report
75
GSM Release Cause for L3 Radio Resource (RR)
76
SIEMENS Release Cause for L3 Radio Resource (RR)
77
GSM Release Cause for Mobility Management (MM)
77
SIEMENS Release Cause for L3 Mobility Management (MM)
78
GSM Release Cause for L3 Call Control (CC)
78
SIEMENS Release Cause for L3 Call Control (CC)
80
SIEMENS Release Cause for L3 Advice of Charge (AOC)
81
GSM Release Cause for Supplementary Service Call
81
SIEMENS Release Cause for Call-Related Supplementary Services (CRSS)
82
SIEMENS Release Cause for Session Management (SM)
83
GSM Cause for L3 Protocol Module or Other Local Cause
84
SIEMENS Release Cause for GPRS API
84
SIEMENS Release Cause for Embedded Netcore
84
ATS18 Extended Call Release Report
85
AT+CPAS Mobile Equipment Activity Status
87
AT+WS46 Select Wireless Network
88
4 Serial Interface Control Commands
89
AT\Q Flowcontrol
89
AT&C Set Circuit Data Carrier Detect (DCD) Function Mode
90
AT&D Set Circuit Data Terminal Ready (DTR) Function Mode
91
AT&S Set Circuit Data Set Ready (DSR) Function Mode
92
ATE Enable Command Echo
93
AT+ILRR Set TE-TA Local Rate Reporting
94
AT+IPR Set Fixed Local Rate
96
Autobauding
98
AT+CMUX Enter Multiplex Mode
99
Restrictions on Multiplex Mode
100
Table 4.1: Availability of at Commands on Virtual Channels
100
Table 4.2: Summary of at Commands with Different Behavior in Multiplex Mode
101
Second Serial Interface ASC1
102
5 Security Commands
103
AT+CPIN Enter PIN
103
What to Do if PIN or Password Authentication Fails
105
AT+CPIN2 Enter PIN2
107
AT^SPIC Display PIN Counter
110
AT+CLCK Facility Lock
115
AT^SLCK Facility Lock
121
AT+CPWD Change Password
122
AT^SPWD Change Password
126
6 Identification Commands
127
ATI Display Product Identification Information
127
AT+CGMI Request Manufacturer Identification
128
AT+GMI Request Manufacturer Identification
129
AT+CGMM Request Model Identification
130
AT+GMM Request TA Model Identification
131
AT+CGMR Request Revision Identification of Software Status
132
AT+GMR Request TA Revision Identification of Software Status
133
AT+CGSN Request Product Serial Number Identification (IMEI) Identical to GSN
134
AT+GSN Request TA Serial Number Identification (IMEI)
135
AT+CIMI Request International Mobile Subscriber Identity
136
7 Call Related Commands
137
Call Status Information
137
ATA Answer a Call
139
ATD Mobile Originated Call to Dial a Number
140
Atd><Mem><N> Originate Call to Phone Number in Memory
143
Atd><N> Originate Call to Phone Number Selected from Active Memory
145
Atd><Str> Originate Call to Phone Number in Memory with Corresponding Field
147
ATDI Mobile Originated Call to Dialable ISDN Number <N
149
ATDL Redial Last Telephone Number Used
150
ATH Disconnect Existing Connection
151
AT+CHUP Hang up Call
152
ATS0 Set Number of Rings before Automatically Answering the Call
153
ATS6 Set Pause before Blind Dialing
155
ATS7 Set Number of Seconds to Wait for Connection Completion
156
ATS8 Set Number of Seconds to Wait for Comma Dialing Modifier
157
ATS10 Set Disconnect Delay after Indicating the Absence of Data Carrier
158
ATP Select Pulse Dialing
159
ATO Switch from Command Mode to Data Mode / PPP Online Mode
160
Switch from Data Mode to Command Mode
161
ATT Select Tone Dialing
162
AT+CBST Select Bearer Service Type
163
AT+CRLP Select Radio Link Protocol Param. for Orig. Non-Transparent Data Call
165
AT+CLCC List Current Calls of ME
167
AT^SLCC Siemens Defined Command to List the Current Calls of the ME
170
AT+CR Service Reporting Control
176
AT+CRC Set Cellular Result Codes for Incoming Call Indication
178
AT+CSNS Single Numbering Scheme
180
AT^SCNI List Call Number Information
182
AT^SLCD Display Last Call Duration
184
AT^STCD Display Total Call Duration
185
8 Network Service Commands
186
AT+COPN Read Operator Names
186
AT+COPS Operator Selection
187
AT+CREG Network Registration
190
AT+CSQ Signal Quality
193
AT^SMONC Cell Monitoring
195
AT^MONI Monitor Idle Mode and Dedicated Mode
197
AT^MONI Responses
198
Service States
199
Notes
199
AT^MONP Monitor Neighbour Cells
201
AT^MONP Responses
202
AT^SMONG GPRS Monitor
203
AT^SMONG Cell Info Table
204
AT^SALS Alternate Line Service
205
AT^SHOM Display Homezone
207
AT^SPLM Read the PLMN List
208
AT^SPLR Read Entry from the Preferred Operators List
209
AT^SPLW Write an Entry to the Preferred Operators List
211
9 Supplementary Service Commands
212
AT+CACM Accumulated Call Meter (ACM) Reset or Query
212
AT^SACM Advice of Charge and Query of ACM and Acmmax
214
AT+CAMM Accumulated Call Meter Maximum (Acmmax) Set or Query
216
AT+CAOC Advice of Charge Information
218
AT+CCUG Closed User Group
220
AT+CCFC Call Forwarding Number and Conditions Control
222
AT+CCWA Call Waiting
226
AT+CHLD Call Hold and Multiparty
230
AT+CLIP Calling Line Identification Presentation
233
AT+CLIR Calling Line Identification Restriction
235
AT+CPUC Price Per Unit and Currency Table
237
AT+CSSN Supplementary Service Notifications
239
AT+CUSD Supplementary Service Notifications
241
10 GPRS Commands
243
AT+CGACT PDP Context Activate or Deactivate
243
AT+CGANS Manual Response to a Network Request for PDP Context Activation
245
AT+CGATT GPRS Attach or Detach
247
AT+CGAUTO Automatic Response to a Network Request for PDP Context Activation
249
AT+CGDATA Enter Data State
251
AT+CGDCONT Define PDP Context
253
AT+CGPADDR Show PDP Address
255
AT+CGQMIN Quality of Service Profile (Minimum Acceptable)
256
AT+CGQREQ Quality of Service Profile (Requested)
260
AT+CGREG GPRS Network Registration Status
264
AT+CGSMS Select Service for MO SMS Messages
266
AT^SGAUTH Set Type of Authentication for PPP Connection
268
AT^SGCONF Configuration of GPRS Related Parameters
269
ATA Manual Response to a Network Request for PDP Context Activation
271
ATD*99# Request GPRS Service
272
ATD*98# Request GPRS IP Service
274
ATH Manual Rejection of a Network Request for PDP Context Activation
275
ATS0 Automatic Response to a Network Request for PDP Context Activation
276
Using GPRS at Commands (Examples)
278
Using the GPRS Dial Command ATD
280
11 FAX Commands
281
FAX Parameters
281
AT+FBADLIN Bad Line Threshold
284
AT+FBADMUL Error Threshold Multiplier
285
AT+FBOR Query Data Bit Order
286
AT+FCIG Query or Set the Local Polling ID
287
AT+FCLASS Fax: Select, Read or Test Service Class
288
AT+FCQ Copy Quality Checking
290
AT+FCR Capability to Receive
291
AT+FDCC Query or Set Capabilities
292
AT+FDFFC Data Compression Format Conversion
293
AT+FDIS Query or Set Session Parameters
294
AT+FDR Begin or Continue Phase C Data Reception
295
AT+FDT Data Transmission
296
AT+FET End a Page or Document
297
AT+FK Kill Operation, Orderly FAX Abort
298
AT+FLID Query or Set the Local ID Setting Capabilities
299
AT+FMDL Identify Product Model
300
AT+FMFR Request Manufacturer Identification
301
AT+FOPT Set Bit Order Independently
302
AT+FPHCTO DTE Phase C Response Timeout
303
AT+FREV Identify Product Revision
304
AT+FRH Receive Data Using HDLC Framing
305
AT+FRM Receive Data
306
AT+FRS Receive Silence
307
AT+FTH Transmit Data Using HDLC Framing
308
AT+FTM Transmit Data
309
AT+FTS Stop Transmission and Wait
310
AT+FVRFC Vertical Resolution Format Conversion
311
12 Short Message Service (SMS) Commands
312
SMS Parameters
312
AT+CMGC Send an SMS Command
316
AT+CMGD Delete SMS Message
317
AT+CMGF Select SMS Message Format
318
AT+CMGL List SMS Messages from Preferred Store
319
AT+CMGR Read SMS Messages
321
AT+CMGS Send SMS Message
323
AT+CMGW Write SMS Messages to Memory
325
AT+CMSS Send SMS Messages from Storage
327
AT+CNMA New SMS Message Acknowledge to ME/TE, Only Phase 2
328
AT+CNMI New SMS Message Indications
330
AT+CPMS Preferred SMS Message Storage
334
AT+CSCA SMS Service Centre Address
337
AT+CSCB Select Cell Broadcast Message Indication
338
AT+CSDH Show SMS Text Mode Parameters
340
AT+CSMP Set SMS Text Mode Parameters
341
AT+CSMS Select Message Service
343
AT^SLMS List SMS Memory Storage
345
AT^SMGL List SMS Messages from Preferred Store Without Setting Status to REC READ
347
AT^SMGO Set or Query SMS Overflow Presentation Mode or Query SMS Overflow
348
AT^SMGR Read SMS Message Without Setting Status to REC READ
350
AT^SSCONF SMS Configuration
351
AT^SSDA Set SMS Display Availability
353
AT^SSMSS Set Short Message Storage Sequence
355
13 SIM Related Commands
356
AT+CRSM Restricted SIM Access
356
AT^SCKS Query SIM and Chip Card Holder Status
358
AT^SCID Display SIM Card Identification Number
360
AT+CXXCID Display Card ID
361
14 SIM Application Toolkit (SAT) Commands
362
AT^SSTA SAT Interface Activation
362
SSTN SAT Notification
364
AT^SSTGI SAT Get Information
366
AT^SSTR SAT Response
368
15 Phonebook Commands
370
Sort Order for Phonebooks
370
AT+CPBR Read from Phonebook
371
AT+CPBS Select Phonebook Memory Storage
374
AT+CPBW Write into Phonebook
376
AT^SPBC Search the First Entry in the Sorted Telephone Book
379
AT^SPBD Purge Phonebook Memory Storage
381
AT^SPBG Read Current Phonebook Entries
383
AT^SPBS Step through the Selected Phonebook Alphabetically
387
AT^SDLD Delete the 'Last Number Redial' Memory
391
16 Audio Commands
392
Audio Programming Model
392
Figure 16.1: Audio Programming Model
392
ATL Set Monitor Speaker Loudness
393
ATM Set Monitor Speaker Mode
394
AT+CLVL Loudspeaker Volume Level
395
AT+CMUT Mute Control
397
AT+VTD Tone Duration
398
AT+VTS DTMF and Tone Generation
399
AT^SAIC Audio Interface Configuration
401
AT^SNFA Set or Query of Microphone Attenuation
403
AT^SNFD Set Audio Parameters to Manufacturer Default Values
405
AT^SNFI Set Microphone Path Parameters
406
AT^SNFM Set Microphone Audio Path and Power Supply
408
AT^SNFO Set Audio Output (= Loudspeaker Path) Parameter
410
AT^SNFPT Set Progress Tones
412
AT^SNFS Select Audio Hardware Set
413
AT^SNFTTY Switch Audio Path to TTY/CTM Mode
417
AT^SNFV Set Loudspeaker Volume
419
AT^SNFW Write Audio Setting in Non-Volatile Store
421
AT^SRTC Ring Tone Configuration
422
17 Hardware Related Commands
425
AT+CALA Set Alarm Time
425
Summary of at Commands Available in Alarm Mode
428
Table 17.1: List of at Commands Available in Alarm and Charge-Only Mode
428
AT+CCLK Real Time Clock
429
AT^SBC Battery Charging / Discharging and Charge Control
430
Summary of at Commands Available in Charge-Only and Alarm Mode
432
AT^SBV Battery/Supply Voltage
433
AT^SCTM Set Critical Operating Temperature Presentation Mode or Query Temperature
434
AT^SSYNC Configure SYNC Pin
437
ME Status Indicated by Status LED Patterns
438
Table 17.2: Modes of the LED and Indicated ME Functions
438
18 Miscellaneous Commands
439
A/ Repeat Previous Command Line
439
ATS3 Write Command Line Termination Character
440
ATS4 Set Response Formatting Character
441
ATS5 Write Command Line Editing Character
442
19 Appendix
443
Restricted Access to SIM Data after SIM PIN Authentication
443
List of *# Codes
444
Table 19.1: List of *# Codes
444
Table 19.2: Abbreviations of Codes and Parameters Used in Table
445
Available at Commands and Dependency on SIM PIN
448
Table 19.3: Available at Commands and Dependency on SIM PIN
448
AT Command Settings Storable with AT&W
455
Table 19.4: Settings Stored to User Profile on ASC0 / MUX Channel 1
455
Table 19.5: Settings Stored to User Profile on ASC1 / MUX Channels 2 and 3
456
Factory Default Settings Restorable with AT&F
458
Table 19.6: Factory Default Settings Restorable with AT&F
458
Summary of Unsolicited Result Codes (URC)
461
Table 19.7: Summary of Unsolicited Result Codes (URC)
461
Alphabetical List of at Commands
463
Table 19.8: Alphabetical List of at Commands
463
Advertisement
Related Products
Siemens MC35 Terminal
Siemens Milltronics MD-36
Siemens Milltronics Millpulse 600
Siemens SIMATIC MOBY D MDS D324
Siemens SIMATIC MOBY D MDS D460
Siemens SIMATIC MOBY D MDS D165
Siemens SIMATIC MOBY D MDS D261
Siemens SIMATIC MOBY D MDS D139
Siemens milltronics WEIGHFEEDER 1200 Series
Siemens Milltronics TASS
Siemens Categories
Industrial Equipment
Controller
Control Unit
Oven
Washer
More Siemens Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL