726+,%$
TBDK-0042
November 2000
This bulletin describes how to upgrade the DK424 to a DK424i system. It also lists the upgrade paths for
various DK424 processors, provides system capacity and line considerations, along with reconfiguration
examples and blank configuration worksheets.
Upgrade Considerations
Upgrade Paths – The following is a list of possible DK424 to DK424i upgrade paths:
o
RCTU A processors (R1~4.x) >> B1, B2, B3, B5 processors
o
RCTU B processors (R1~4.x) >> B2, B3, B5 processors
o
RCTUC/D processors (R1~4.x) >> B3 & B5 processors
o
RCTU E/F processors (R3~4.x) >> B5 processors
Note
For a specific list of all processors, see Page 6 of this bulletin.
System Capacity Verification – Make sure the DK424i system you are upgrading to provides enough
PCB slots, station ports, and CO lines to match the existing DK424 system (see tables below).
DK424i Maximum System Capacities with only Digital T1/PRI Line PCBs
B1CU
1 Cabinet
8 Universal slots
56 Stations Max.
32 T1/PRI lines Max.
64 Stations & Digital lines
B1CU
DK424 to DK424i Upgrade
Procedure Using DKi Admin
B2CAU/B2CBU
2 Cabinets
14 Universal slots
112 Stations Max.
120 T1/PRI lines Max.
128 Stations & Digital lines
DK424i Maximum System Capacities with only Analog Line PCBs
B2CAU/B2CBU
Toshiba America Information Systems, Inc.
Telecommunication Systems Division
9740 Irvine Blvd., Irvine, CA 92618-1697 (949) 583-3700
http://telecom.toshiba.com
Technical Bulletin
B3CAU/B3CBU
3 Cabinets
28 Universal slots
192 Stations Max.
120 T1/PRI lines Max.
248 Stations & Digital lines
B3CAU/B3CBU
Strata
DK
®
4031068
B5CAU/B5CBU
5 Cabinets
48 Universal slots
336 Stations Max.
196 T1/PRI lines Max.
432 Stations & Digital lines
B5CAU/B5CBU