Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
You can loop the PROFINET IO via the M12 round socket Note Configuration Manual SIMATIC RF360R You can find a detailed description of commissioning and configuration of the reader in the "SIMATIC RF360R (https://support.industry.siemens.com/cs/ww/en/ps/26319/man)" configuration manual. 1.1.2 Ordering data Table 1-1...
4. Screw the cable lug together with the M3 fastening screws with a torque of 1.2 Nm. NOTICE Low-impedance connection Ensure a low impedance connection between the reader module and the functional ground. When attaching the grounding cable, ensure it is not on a coated surface. SIMATIC RF300 System Manual, xx/2020, C79000-G8976-C345-08...
If you want to make the cable yourself, ensure that the conductor cross-section matches the system setup or the corresponding protection (1.5 mm When using cables that are not preassembled, you need the tool for the specific cable/connector, for example, an insulation stripper, screwdriver or Allen wrench. SIMATIC RF300 System Manual, xx/2020, C79000-G8976-C345-08...
The following tables show the pin assignment for the interfaces/connectors. Table 1-2 Pin assignment power supply; M12 socket (4-pin, L-coded) Assignment View of M12 socket, 4-pin +24 V (brown) Unassigned (white) Ground/shield (blue) Reset to Factory (black) SIMATIC RF300 System Manual, xx/2020, C79000-G8976-C345-08...
Operating mode "without presence": Transponder present and command cur‐ rently being executed There is an error. The number of flashes provides information about the current error. You can find more information on error messages in the section "AUTOHOTSPOT". SIMATIC RF300 System Manual, xx/2020, C79000-G8976-C345-08...
• LED test while the reader is starting up. • A connection is available. 1.1.7 Ensuring reliable data exchange The "center point" of the transponder must be situated within the transmission window. SIMATIC RF300 System Manual, xx/2020, C79000-G8976-C345-08...
The RF360R can be flush-mounted in metal. Allow for a possible reduction in the field data. To avoid any influence on the field data, the distance "a" should be kept to. a ≥ 20 mm Figure 1-2 Metal-free area for RF360R SIMATIC RF300 System Manual, xx/2020, C79000-G8976-C345-08...
Minimum distance between several RF360R readers RF360R side-by-side D ≥ ≥ 350 mm (with 2 readers) ≥ 500 mm (with more than 2 readers) Figure 1-3 Minimum distance between several RF360R readers RF360R face-to-face D ≥ 500 mm SIMATIC RF300 System Manual, xx/2020, C79000-G8976-C345-08...
EN 301489, CE, FCC, UL/CSA (IEC 61010) MTBF 65 years 1.1.11 Approvals FCC information Siemens SIMATIC RF360R (MLFB 6GT2801-5BA30); FCC ID NXW-RF360R This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: SIMATIC RF300 System Manual, xx/2020, C79000-G8976-C345-08...
Page 15
NOTE 1: These levels of transient overvoltage are typical for equipment supplied from the building wiring. • f) using a "NEC Class 2" power supply is required • g) the device is categorized as pollution degree 3/4 SIMATIC RF300 System Manual, xx/2020, C79000-G8976-C345-08...