Page 1
GT series Connection with other companies’ PLCs Manual ARCT1F449E-12 2017.7 panasonic.net/id/pidsx/global...
Page 2
Copyright / Trademarks - This manual and its contents are copyrighted. - You may not copy this manual in whole or part, without written consent of Panasonic Industrial Devices SUNX Co., Ltd. - Windows is a registered trademark of Microsoft Corporation in the United States and other countries.
Table of Contents Applicable PLCs Manufactured by Various Companies Selecting the PLC Model 1. Connection With Mitsubishi PLCs............1-1 1.1 MELSEC-FX1S/ FX1N/ FX1NC Series................1-2 1.1.1 Direct connection to the TOOL port ................1-3 1.1.2 Using an Adapter ......................1-4 1.2 MELSEC-FX2N/ FX2NC/ FX3U/ FX3UC/ FX3G / FX3GC Series ........
Page 4
2.2.4 SYSMAC CJ2M series (1:1) (RS232C) ..............2-21 2.2.5 SYSMAC CJ2M series (RS422/RS485) ..............2-21 2.2.6 When using the peripheral port ................. 2-22 3. Connection With Toshiba Machine PLCs ..........3-1 3.1 PROVISOR TCmini Series ....................3-2 3.1.1 RS232C Connection ....................3-3 3.1.2 RS485 connection .......................
Page 5
8.5.1 Connection Method ....................8-12 8.6 KV-3000 Series ....................... 8-13 8.6.1 Connection Method ....................8-14 8.7 KV-3000/5000 Series Connected using Unit KV-L20R/V ..........8-15 8.7.1 Connection Method ....................8-17 8.8 KV Nano Series ......................8-18 8.8.1 Connection Method ....................8-19 8.9 KV Nano Series Connected using Unit KV-L20R/V ............
○: Connection is possible using the communications unit or a signal conversion cable, etc. Blank: Not evaluated. *1. PLCs other than FP series of Panasonic may be limited in the type of device that can be used and addresses. Please see each wiring diagram for details.
Page 8
○: Connection is possible using the communications unit or a signal conversion cable, etc. Blank: Not evaluated. *1. PLCs other than FP series of Panasonic may be limited in the type of device that can be used and addresses. Please see each wiring diagram for details.
Page 9
○: Connection is possible using the communications unit or a signal conversion cable, etc. Blank: Not evaluated. *1. PLCs other than FP series of Panasonic may be limited in the type of device that can be used and addresses. Please see each wiring diagram for details.
Page 10
○: Connection is possible using the communications unit or a signal conversion cable, etc. Blank: Not evaluated. *1. PLCs other than FP series of Panasonic may be limited in the type of device that can be used and addresses. Please see each wiring diagram for details.
Page 11
○: Connection is possible using the communications unit or a signal conversion cable, etc. Blank: Not evaluated. *1. PLCs other than FP series of Panasonic may be limited in the type of device that can be used and addresses. Please see each wiring diagram for details.
PLC Model selection with GTWIN Select the model of PLC being used from among the list of candidates Usable GT GT01,GT02,GT02L,GT03-E, PLC Model GT05,GT11,GT12,GT21, GT10 GT30 GT32,GT32-R,GT32-E, GT703,GT704,GT707 Panasonic FP series ○ ○ ○ Panasonic FP7 series ○ (Except GT01,GT11,GT21) ○ ○ General-Purpose Serial (General-purpose RS232C device, such as ○...
1.1.1 Direct connection to the TOOL port For 5V DC type Wiring diagram GT Series TOOL port of FX1S RS422 FX1N Mini-DIN 8-pin 5V DC type FX1NC loose-wire cable (AIGT8152) Note: • Keep the cable no longer than 2 m •...
1.1.2 Using an Adapter Adapter Wiring diagram GT Series GT series RS232C 24 V DC type*1 *2 FX1S FX1N FX1N-232-BD FX1NC GT707 *1: Although nos.6 and 7 of the models except GT01 are RS/CS, they can be used in the above connection.
1.2 MELSEC-FX2N/ FX2NC/ FX3U/ FX3UC/ FX3G / FX3GC Series Applicable versions of GTWIN and GT series Applicable versions of GTWIN and GT series FX2N・FX2NC・ FX3GC FX3U・FX3UC・FX3G GT01 Ver.1.10 or later Cannot be used GT02 Ver.1.00 or later Ver.1.62 or later GT02L Ver.1.00 or later...
Page 18
Communication Parameters Settings The example of communication settings of GT and PLC is shown below. Setting Values for GT (Set in the configuration setting of GTWIN.) Setting Values for GT Item Setting Baud Rate 9600bps Data Length Stop Bits Parity Even Setting Values for PLC (Computer link unit) Specify 0 to D8120...
1.2.1 Direct connection to the TOOL port For RS422 5V DC type Wiring diagram GT Series FX2N FX2NC TOOL port of RS422 FX3U Mini-DIN 8-pin 5V DC type FX3UC loose-wire cable (AIGT8152) FX3G FX3GC Note: • Keep the cable no longer than 2 m •...
1.2.2 Using an Adapter Adapter Wiring diagram GT Series FX2N FX2N-232-BD FX2NC GT series RS232C FX3U FX3UC-232-BD 24 V DC FX3UC FX3U-232-ADP type*1 *2 FX3G FX3G-232-BD GT707 *1: Although nos.6 and 7 of the models except GT01 are RS/CS, they can be used in the above connection.
1.3 MELSEC-L (Serial communication) Series PLC model selection Select " Mitsubishi MELSEC-Q (Serial communication) series". Usable devices Bit/Word Device Input Relay X000000-X001FFF Output Relay Y000000-Y001FFF Internal Relay M000000-M032767 Latch relay L000000-L032767 Annunciator F000000-F032767 Edge relay V000000-V032767 Link Relay B000000-B007FFF Special relay SM000000-SM002047 Link special relay SB000000-SB0007FF...
Page 22
Bit/Word Device Memo Input Relay X000000-X001FF Specify address expression every 0 Output Relay Y000000-Y001FF0 Specify address expression every 0 Specify address expression every 16 Internal Relay M000000-M032752 multiples Latch relay L000000-L032752 Annunciator F000000-F032752 Edge relay V000000-V032752 Link Relay B000000-B007FF0 Specify address expression every 10 Special relay SM000000-SM002032 Link special relay...
Page 23
PLC Unit No. Baud Rate 19200bps Data Length Stop Bits Parity Sum Check *GT series supports the format 4 of QnA compatible 4C frame. Setting Values for PLC (Serial communication unit) Item Setting Station Number Baud Rate 19200bps Data Length...
1.3.1 MELSEC-L (Serial communication) series Serial communication Wiring diagram GT Series module GT series RS232C type*1 *2 L26CPU-BT LJ71C24 L02SCPU GT707 *1: Although nos.6 and 7 of the models except GT01 are RS/CS, they can be used in the above connection.
1.4 MELSEC-L (CPU) Series PLC model selection Select " Mitsubishi MELSEC-Q (Serial communication) series". Usable devices Bit/Word Device Input Relay X000000-X001FFF Output Relay Y000000-Y001FFF Internal Relay M000000-M032767 Latch relay L000000-L032767 Annunciator F000000-F032767 Edge relay V000000-V032767 Link Relay B000000-B007FFF Special relay SM000000-SM002047 Link special relay SB000000-SB0007FF...
Page 26
Bit/Word Device Memo Input Relay X000000-X001FF Specify address expression every 0 Output Relay Y000000-Y001FF0 Specify address expression every 0 Specify address expression every 16 Internal Relay M000000-M032752 multiples Latch relay L000000-L032752 Annunciator F000000-F032752 Edge relay V000000-V032752 Link Relay B000000-B007FF0 Specify address expression every 10 Special relay SM000000-SM002032 Link special relay...
Page 27
PLC Unit No. Baud Rate 19200bps Data Length Stop Bits Parity Sum Check *GT series supports the format 4 of QnA compatible 4C frame. Setting Values for PLC (Serial communication module) Item Setting Station Number Baud Rate 19.2 Kbps Data Length...
1.4.1 MELSEC-L (CPU) Series Link I/F Wiring diagram GT Series GT series RS232C type*1 RS232C L02SCPU port on CPU unit GT707 *1: This is for RS232C type of GT01/GT02/GT02L/GT03-E/GT05/GT11/GT12/GT21/GT32/ GT32-E/GT703/GT704. 1-16...
1.5 MELSEC-Q (Serial communication) Series PLC model selection Select " Mitsubishi MELSEC-Q (Serial communication) Series". *When directly connecting to the RS232C port of Q00CPU or Q01CPU Select "Mitsubishi MELSEC-Q (Serial communication) Series" for the PLC model. Usable devices Bit/Word Device Input Relay X000000-X001FFF Output Relay...
Page 30
Bit/Word Device Memo Input Relay X000000-X001FF Specify address expression every 0 Output Relay Y000000-Y001FF0 Specify address expression every 0 Specify address expression every 16 Internal Relay M000000-M032752 multiples Latch relay L000000-L032752 Annunciator F000000-F032752 Edge relay V000000-V032752 Link Relay B000000-B007FF0 Specify address expression every 10 Special relay SM000000-SM002032 Link special relay...
Page 31
PLC Unit No. Baud Rate 19200bps Data Length Stop Bits Parity Sum Check *GT series supports the format 4 of QnA compatible 4C frame. Setting Values for PLC (Serial communication module) Item Setting Station Number Baud Rate 19200bps Data Length...
1.5.1 MELSEC-Q (Serial communication) series (RS232C) Serial communication Wiring diagram GT Series module GT series RS232C type*1 *2 Q02CPU Q02HCPU Q06HCPU Q12HCPU QJ71C24N Q25HCPU QJ71C24-R2 Q00CPU QJ71C24N-R2 Q00HCPU Q01CPU Q00JCPU Q26UDHCPU GT707 *1: Although nos.6 and 7 of the models except GT01 are RS/CS, they can be used in the above connection.
1.5.3 When directly connecting to the RS232C port of Q00CPU/ Q00UJCPU/ Q01CPU Link I/F Wiring diagram GT Series GT series RS232C type*1 *2 Q00CPU RS232C port on Q00UJCPU CPU unit Q01CPU GT707 *1: Although nos.6 and 7 of the models except GT01 are RS/CS, they can be used in the above connection.
1.6 MELSEC-Q (CPU) Series PLC model selection Select "MELSEC-Q (CPU) series". Usable devices Bit/Word Device Memo Input Relay X000000-X001FFF Output Relay Y000000-Y001FFF Internal Relay M000000-M032767 Latch relay L000000-L032767 Annunciator F000000-F032767 Edge relay V000000-V032767 Link Relay B000000-B007FFF Special relay SM000000-SM002047 Device Link special relay SB000000-SB0007FF Step relay...
Page 35
Data Length Stop Bits Parity The communication condition setting at the PLC side is not required. Uncheck the box of “Use Serial Communication”. 1.6.1 MELSEC-Q (CPU) Series Link I/F Wiring diagram GT Series GT series RS232C type*1 Q02CPU Q02HCPU RS232C Q06HCPU...
1.7 MELSEC-A (Computer Link) Series GT703/GT704/GT707 cannot be used. PLC model selection Select "Mitsubishi MELSEC-A (Computer Link) Series". Usable devices Bit/Word Device Memo Input Relay X0000-X07FF Output Relay Y0000-Y07FF Internal Relay M0000-M2047 Bit Device Link Relay B0000-B03FF Timer(contact) TS0000-TS0255 Counter(contact) CS0000-CS0255 Input Relay X0000-X07F0...
Page 37
1.7.1 MELSEC-A (Computer Link) Series Computer Link Wiring diagram GT Series module AJ71C24 AJ71C24-S3 AJ71C24-S6 AJ71C24-S8 AJ71UC24 (Only A2N) GT series RS232C A1SJ71C24-R2 type*1 A1SJ71UC24-R2 A1SJ A2SH A1SJ71UC24-R2 A1SH RS232C port on A2CCPU24 CPU unit *1: Although nos.6 and 7 of the models except GT01 are RS/CS, they can be used in the above connection.
2.1 Omron SYSMAC-C Series (C/α/CV/CP1) PLC model selection Select "Omron SYSMAC-C series." Usable devices Bit/Word Device I/O Relay Internal Hold Relay 000000-614315 Special Auxiliary Relay Data link Relay LR00000-LR19915 Bit Device Auxiliary Memory Relay AR00000-AR95915 Hold Relay HR00000-HR51115 Timer(contact) TIM0000-TIM4095 Counter(contact) CNT0000-CNT4095 I/O Relay...
Page 41
Communication Parameters Settings The example of communication settings of GT and PLC is shown below. Setting Values for GT (Set in the configuration setting of GTWIN.) Item Setting Baud Rate 19200bps Data Bits Stop Bits Parity Even Setting Values for PLC Item Setting Mode of PLC...
Page 42
For almost all models the PLC communication setting method is as follows. However, differences may arise depending on the model. For details, please consult the manual for the PLC you will use when making the settings. To communicate using the RS232C port of the CPU unit Set the system area as follows.
2.1.1 SYSMAC C series (using link interface) (RS232C) Link I/F Wiring diagram GT series GT series RS232C type*5 *6 C200H-LK201 *1 C200H C120-LK201-V1 *2 GT707 GT series RS232C type*5 *6 C200H-LK201 *1 C120-LK201-V1 *2 GT707 C200HS GT series RS232C type*5 *6...
Page 44
Link I/F Wiring diagram GT series C500 C500F C120-LK201-V1 *2 C1000H C500-LK201-V1 *1 GT series C2000 C500-LK203 *1 RS232C C2000H type*5 *6 C1000HF C500-LK203 *1 GT707 GT series RS232C type*5 *6 C20H Link interface on the CPU C28H unit *3...
Page 45
Link I/F Wiring diagram GT series RS232C port on CPU CQM1-CPU42 unit CPM1-CIF01 GT series SRM1-C02 RS232C port on CPU RS232C CPM2A unit type*5 *6 CPM1-20CDR-A CPM1-CIF01 RS232C port on CPU CQM1H-CPU21 unit GT707 CPM2C-CIF01-V1 CPM2C *4 CPM2C-CIF11 CPM2C-CIF21 GT series...
2.1.3 SYSMAC CV series (using link interface) (RS232C) Link I/F Wiring diagram GT series Communication port 1 connections GT series RS232C type*2 *3 Communication port 2 connections CV500 CV1000 CV500-LK201 CVM1 Communication port 1 connections GT707 Communication port 2 connections...
Link I/F Wiring diagram GT series GT series RS232C type*2 *3 CV500 Link interface on CV1000 the CPU unit *1 CVM1 GT707 *1: Connect to the HOSTLINK port. *2: Although nos.6 and 7 of the models except GT01 are RS/CS, they can be used in the above connection.
2.1.5 SYSMAC CP1 series (RS422/RS485) Connected with Adapter or Unit Link I/F Wiring diagram GT series RS422/485 RS422/RS485 CP1H optional board type CP1W/CIF11 Refer to the figures below for the settings of the dip switches of RS422/RS485 conversion adapter CJ1W-CIF11.
2.1.7 When using the peripheral port of CPM2C The wiring diagrams vary according to the connection cables for the peripheral port to be used. Connection cable Omron for peripheral port Wiring diagram GT series made by Omron GT series RS232C type*1 *2 CS1W-CN118...
Page 51
Connection cable Omron for peripheral port Wiring diagram GT series made by Omron GT series RS232C type*1 *2 CS1W-CN226 CPM2 CS1W-CN626 GT707 *1: Although nos.6 and 7 of the models except GT01 are RS/CS, they can be used in the above connection.
PLC model selection Select "Omron SYSMAC-CS/CJ series". Usable devices vary according to the version of GTWIN. There is a restriction on the version of GT firmware if the GTWIN is Ver2.96 or later. GT Series GTWIN Version GT Version GT01 Ver.1.343 or later...
Page 53
* 1 The input in GTWIN is as follows: * 2 The input in GTWIN is as follows: * 3 The input in GTWIN is as follows: * 4 For details, please consult the manual for the PLC you will use. Usable devices (When the version of GTWIN is 2.95 or older) There is no restriction on the version of GT firmware if the version of GTWIN is older than Ver2.95.
Page 54
Communication Parameters Settings The example of communication settings of GT and PLC is shown below. Setting Values for GT (Set in the configuration setting of GTWIN.) Item Setting Baud Rate 19200bps Data Bits Stop Bits Parity Even Setting Values for PLC Item Setting Mode of PLC...
Page 55
For almost all models the PLC communication setting method is as follows. However, differences may arise depending on the model. For details, please consult the manual for the PLC you will use when making the settings. To communicate using the RS232C port of the CPU unit Set the system area as follows.
2.2.1 SYSMAC CS1 series (1:1) (RS232C) Link I/F Wiring diagram GT series RS232C port on CPU unit CS1W-SCU21-V1 GT series CS1W-SCB21-V1 RS232C type*2 *3 CS1H-CPU67 CS1H-CPU66 CS1H-CPU65 CS1H-CPU64 CS1H-CPU63 CS1G-CPU45 CS1G-CPU44 CS1W-SCB41-V1 CS1G-CPU43 CS1G-CPU42 GT707 *1: A connection cable for peripherals is required for the connection to the peripheral port.
2.2.2 SYSMAC CJ1 series (1:1) (RS232C) Link I/F Wiring diagram GT series GT series RS232C type*2 *3 CJ1H RS232C port on CJ1M the CPU unit CJ1G GT707 *1: A connection cable for peripherals is required for the connection to the peripheral port.
2.2.3 SYSMAC CS1/CJ1 series (1:1) (RS422/RS485) Connected with Adapter, or Unit Link I/F Wiring diagram GT series series RS422 conversion adapter CJ1W-CIF11 RS422/RS485 type RS422 conversion unit series NT-AL001 Note: Refer to the figures below for the settings of the dip switches of RS422/485 optional board CPW-CFIF11 and RS422 conversion unit NT-AL001.
2.2.4 SYSMAC CJ2M series (1:1) (RS232C) Link I/F Wiring diagram GT series RS232C port on CJ2M-CPU1□ the CPU unit GT series RS232C type*1 *2 RS232C option CJ2M-CPU3□ board CP1W-CIF01 GT707 *1: Although nos.6 and 7 of the models except GT01 are RS/CS, they can be used in the above connection.
2.2.6 When using the peripheral port The wiring diagrams vary according to the connection cables for the peripheral port to be used. Connection cable for Omron PLC Wiring diagram GT series peripheral port made by Omron GT series CS1H-CPU67 RS232C...
Page 61
Connection cable for Omron PLC Wiring diagram GT series peripheral port made by Omron GT series RS232C type*1 CS1W-CN225 CS1W-CN625 CS1H-CPU67 GT707 CS1H-CPU66 CS1H-CPU65 CS1H-CPU64 CS1H-CPU63 CS1G-CPU45 CS1G-CPU44 CS1G-CPU43 CS1G-CPU42 CJ1H GT series CJ1M RS232C CJ1G type*1 CS1W-CN226 CS1W-CN626 GT707 *1: This is for RS232C type of GT01/GT02/GT02L/GT03-E/GT05/GT11/GT12/GT21/GT32/ GT32-E/GT703/GT704.
Parity None 3.1.1 RS232C Connection Wiring diagram GT series GT series RS232C type*1 *2 GT707 *1: Although nos.6 and 7 of the models except GT01 are RS/CS, they can be used in the above connection. *2: This is for RS232C type of GT01/GT02/GT02L/GT03-E/GT05/GT11/GT12/GT21/GT32/...
Set it to the host communication protocol connection mode. * For information on the setting method, refer to the “Tcmini” manual. In case of 7 pins Wiring diagram GT series RS422/RS485 type In case of 8 pins Wiring diagram GT series...
4.1 Allen-Bradley SLC500 MicroLogix Series PLC model selection Select "Allen-Bradley SLC500 MicroLogix Series". Usable devices vary according to the version of GTWIN. Usable devices (When the version of GTWIN is Ver.2.96 or later) Bit/Word Device B 3:0/0~B 255:255/15 Input I: 0.0/0~I: 30.255/15 Output O: 0.0/0~O: 30.255/15 Status...
Page 69
Note: Restrictions on character string device When using the ST (character string) of character string device, it is used only as a character string. When referring devices, use the data format "ASCII" of data parts. When writing character strings from GT, specify the number of characters for the sub-element 0 on the PLC side.
Page 70
Usable devices (When the version of GTWIN is 2.95 or older) Bit/Word Device Bit Device B3:000/ 0-B3:255/ 15 B3:000-B3:255 Word Device Integer N7:000-N7:255 The following list illustrates each expression of PLC device in GTWIN. When you enter a value of devices, follow below expression. Expression in PLC Expression in GTWIN Bit Device...
4.1.1 SLC500 series(using link interface on the CPU unit) Wiring diagram GT series GT series RS232C type*1 *2 SLC-5/03 SLC-5/04 GT707 *1: Although nos.6 and 7 of the models except GT01 are RS/CS, they can be used in the above connection.
MicroLogix1000/1100 and PC TO MICROLOGIX COMMS. CABLE are connected as follows, then connect to GT by the cable of following wiring diagram. Wiring diagram GT series GT series RS232C type*1 *2 MicroLogix1000/1100 GT707 *1: Although nos.6 and 7 of the models except GT01 are RS/CS, they can be used in the above connection.
5.1 Siemens S7-200 Series PLC model selection Select "Siemens S7-200 series". Usable devices Bit/Word Device Memo Input I00-I77 Output Q00-Q77 Bit Memory M00-M317 Bit Device Timer(contact) T00-T255 Counter(contact) C00-C255 Special Memory SM00-SM1947 Sequence Control Relay S00-S317 Input IW0-IW6 Address should be an even number Output QW0-QW6 Address should be an even number...
5.1.1 RS232C Connection (Connected with PC/PPI Cable) S7-200 and PC/PPI Cable are connected as follows, then connect to GT by the cable of following wiring diagram. Wiring diagram GT series GT series RS232C type*1 *2 CPU212 CPU214 CPU215 CPU216 CPU222 GT707 *1: Although nos.6 and 7 of the models except GT01 are RS/CS, they can be used in the above...
6.1 MASTER-K (Cnet) Series PLC model selection Select "LG MASTER-K (Cnet) Series". Usable devices Bit/Word Device Input/Output P0000-P063F Bit Device Internal Relay M0000-M191F Input/Output PW0000-PW0063 Word Device Internal Relay MW0000-MW0191 Data Register D0000-D9999 Communication Parameters Settings The example of communication settings of GT and PLC is shown below. Setting Values for GT (Set in the configuration setting of GTWIN.) Item Setting...
6.1.1 Connection Method Link I/F Wiring diagram GT series RS232C port on CPU unit GT series RS232C type*1 *2 RS232C port 200S on CPU unit GT707 200S G6L-CUEB GT series RS232C 300S G4L-CUEA type*1 *2 1000S G3L-CUEA GT707 *1: Although nos.6 and 7 of the models except GT01 are RS/CS, they can be used in the above connection.
7.1 FA-M3 Series PLC model selection Select "Yokogawa FA-M3 Series" Usable devices Bit/Word Device Memo Specify by slot number(1 digit) + unit number(2 Input Relay X00201-X71664 digit) + terminal number(2 digit) Specify by slot number(1 digit) + unit number(2 Output Relay Y00201-Y71164 digit) + terminal number(2 digit) Internal Relay...
Page 83
Communication Parameters Settings The example of communication settings of GT and PLC is shown below. Setting values for GT (Set in the configuration setting of GTWIN.) Item Setting PLC Unit No. Baud Rate 19200bps Length of Bits Stop Bits Parity None Setting Values for PLC (Link I/F) Item...
7.1.1 Connection Using PC Link Module PC link module Wiring diagram GT series GT series RS232C F3SP21-0N type*1 *2 F3SP25-2N F3SP28-3N F3SP28-3S F3SP35-5N F3LC11-1N F3SP38-6N F3LC11-1F F3SP38-6S F3LC12-1F F3SP53-4H F3SP53-4S F3SP58-6H F3SP58-6S F3SP59-7S GT707 *1: Although nos.6 and 7 of the models except GT01 are RS/CS, they can be used in the above connection.
7.1.2 CPU Direct Connection PLC and a cable for a programming tool (KM11-2T) are connected as follows, then connect to GT by the cable of following wiring diagram. Conversion cable Wiring diagram GT series GT series RS232C F3SP21-0N type*1 *2...
8.1 KV-10/16/24/40 Series PLC model selection Select "Keyence KV-10/16/24/40 series". Confirm the appropriate versions of GTWIN and GT to connect with Keyence KV-10/16/24/40 series. GT series GTWIN Version GT Version GT01 Ver.2.80 or later Ver.1.31 or later GT02 Ver.2.A0 or later Ver.1.00 or later...
Page 89
Even 8.1.1 Connection Method Wiring diagram GT series GT series RS232C type*2 *3 GT707 *1: The numbers of module connector on the PLC show the pin numbers on the unit. *2: Although nos.6 and 7 of the models except GT01 are RS/CS, they can be used in the above connection.
8.2 KV-700 Series PLC model selection Select “Keyence KV-700 Series”. Usable devices Memo Bit/Word Device Relay 00000-59915 Control Relay CR0000-CR3915 Timer T000-T511 Bit Device Counter C000-C511 It is not possible to output High-speed Counter Comparator CTC0-CTC3 Data Memory DM00000-DM39999 Word Device Control Memory CM0000-CM3999 Temporary Data Memory...
8.2.1 Connection Method Wiring diagram GT series GT series RS232C type*2 *3 GT707 *1: The numbers of module connector on the PLC show the pin numbers on the unit. *2: Although nos.6 and 7 of the models except GT01 are RS/CS, they can be used in the above connection.
8.3 KV-700 Series Connected using Unit KV-L20R/V PLC model selection Select “Keyence KV-700 Series”. Usable devices Memo Bit/Word Device Relay 00000-59915 Control Relay CR0000-CR3915 Timer T000-T511 Bit Device Counter C000-C511 It is not possible to High-speed Counter Comparator CTC0-CTC3 output it. Data Memory DM00000-DM39999 Word Device...
8.3.1 Connection Method Wiring diagram GT Series GT series RS232C type*1 *2 GT707 *1: Although nos.6 and 7 of the models except GT01 are RS/CS, they can be used in the above connection. *2: This is for RS232C type of GT01/GT02/GT02L/GT03-E/GT05/GT11/GT12/GT21/GT32/...
8.4 KV-1000 Series PLC model selection Select “Keyence KV-1000 Series”. Usable devices Bit/Word Device Memo Relay 00000-59915 Control Relay CR0000-CR3915 Internal Hold Relay MR00000-MR99915 Latch Relay LR00000-LR99915 Bit Device Timer T0000-T3999 Counter C0000-C3999 It is not possible to output High-speed Counter Comparator CTC0-CTC3 Data Memory DM00000-DM65534...
8.4.1 Connection Method Wiring diagram GT series GT series RS232C type*1 *2 GT707 *1: Although nos.6 and 7 of the models except GT01 are RS/CS, they can be used in the above connection. *2: This is for RS232C type of GT01/GT02/GT02L/GT03-E/GT05/GT11/GT12/GT21/GT32/...
8.5 KV-1000 Series Connected using Unit KV-L20R/V PLC model selection Select “Keyence KV-1000 Series”. The following version of GTWIN is required to select “Keyence KV-1000 series” from the PLC model selection. When the version of your GTWIN is older than the one below, select “Keyence KV-700 series”. In that case, the range of usable devices is the same as the one for Keyence KV-700 series.
Page 97
Communication Parameters Settings The example of communication settings of GT and PLC is shown below. Setting Values for GT (Set in the configuration setting of GTWIN.) Item Setting Baud Rate 9600/19200/38400/57600/115200 bps Data Bits Stop Bits Parity Even KV-L20R Setting (Port1) Item Setting Operation...
8.5.1 Connection Method Wiring diagram GT Series GT series RS232C type*1 *2 GT707 *1: Although nos.6 and 7 of the models except GT01 are RS/CS, they can be used in the above connection. *2: This is for RS232C type of GT01/GT02/GT02L/GT03-E/GT05/GT11/GT12/GT21/GT32/ GT32-E/GT703/GT704.
8.6 KV-3000 Series PLC model selection Select "Keyence KV-3000/5000 Series". KV-5000 series cannot be connected to CPU directly. Usable devices Bit/Word Device Memo Input Relay Output Relay R 00000~R 99915 Internal Auxiliary Relay Link Relay B 0000~B 3FFF Control Relay CR0000-CR3915 Internal Hold Relay MR00000-MR99915...
8.6.1 Connection Method Wiring diagram GT series GT series RS232C type*2 *3 GT707 *1: The numbers of module connector on the PLC show the pin numbers on the unit. *2: Although nos.6 and 7 of the models except GT01 are RS/CS, they can be used in the above connection.
8.7 KV-3000/5000 Series Connected using Unit KV-L20R/V PLC model selection Select "Keyence KV-3000/5000 Series". Usable devices Bit/Word Device Memo Input Relay Output Relay R 00000~R 99915 Internal Auxiliary Relay Link Relay B 0000~B 3FFF Control Relay CR0000-CR3915 Internal Hold Relay MR00000-MR99915 Bit Device Latch Relay...
Page 102
Communication Parameters Settings The example of communication settings of GT and PLC is shown below. Setting values for GT (Set in the configuration setting of GTWIN.) Item Setting Baud Rate 9600/19200/38400/57600/115200 bps Data Bits Stop Bits Parity Even KV-L20R Setting (Port1) Item Setting Operation...
8.7.1 Connection Method Wiring diagram GT Series GT series RS232C type*1 *2 GT707 *1: Although nos.6 and 7 of the models except GT01 are RS/CS, they can be used in the above connection. *2: This is for RS232C type of GT01/GT02/GT02L/GT03-E/GT05/GT11/GT12/GT21/GT32/ GT32-E/GT703/GT704.
8.8 KV Nano Series Applicable versions of GTWIN and GT series GT series Applicable versions GT01 Cannot be used GT02 Ver.1.00 or later GT02L Ver.1.00 or later GT03-E Ver.1.00 or later GT05 Ver.1.00 or later GT11 Cannot be used GT12 Ver.1.00 or later...
Not used 8.8.1 Connection Method Wiring diagram GT series GT series RS232C type*2 *3 GT707 *1: The numbers of module connector on the PLC show the pin numbers on the unit. *2: Although nos.6 and 7 of the models except GT01 are RS/CS, they can be used in the above connection.
8.9 KV Nano Series Connected using Unit KV-L20R/V Applicable versions of GTWIN and GT series GT series Applicable versions GT01 Cannot be used GT02 Ver.1.00 or later GT02L Ver.1.00 or later GT03-E Ver.1.00 or later GT05 Ver.1.00 or later GT11...
Page 107
Communication Parameters Settings The example of communication settings of GT and PLC is shown below. Setting Values for GT (Set in the configuration setting of GTWIN.) Item Setting Baud Rate 9600/19200/38400/57600/115200 bps Data Bits Stop Bits Parity Even KV-N10L Setting (port 1) Item Setting Operation...
8.9.1 Connection Method Wiring diagram GT Series GT series RS232C type*1 *2 GT707 *1: Although nos.6 and 7 of the models except GT01 are RS/CS, they can be used in the above connection. *2: This is for RS232C type of GT01/GT02/GT02L/GT03-E/GT05/GT11/GT12/GT21/GT32/ GT32-E/GT703/GT704.
9.1 EH-150/EHV Series PLC model selection Select "Hitachi EH/EHV series". Usable devices Bit/Word Device Memo External input X 00000~X 4FF95 External output Y 00000~Y 4FF95 Internal output R 000~R FFF Internal output WR 0000.0~WR FFFF.F CPU link L 00000~L 73FFF Internal output WN 00000.0~WN 1FFFF.F Data area...
Page 111
Communication Parameters Settings The example of communication settings of GT and PLC is shown below. Setting Values for GT (Set in the configuration setting of GTWIN.) Item Setting Baud Rate 19200bps Data Length Stop Bits Parity Bit Even Setting Values for PLC Setting for -CPU104A/EH-CPU208A/EH-CPU316A/EH-CPU516/EH-CPU548 When using Port 1 The settings for the dip switches and special internal output are required.
Page 112
Setting for EHV-CPU128/EHV-CPU64/EHV-CPU32/EHV-CPU16 It should be specified with a programming tool. Specify the setting for the serial port as below with a programming tool. Item Setting Type Special port For RS232C connection: RS232C Port type *1 For RS422 connection: RS422/485 For RS485 connection: RS422/485 Baud rate 19200bps...
9.1.1 RS232C Connection When connecting with EH-RS05 and a self-produced cable Link I/F Wiring diagram GT series EH-CPU104A EH-CPU208A Port 1 or EH-CPU316A Port 2 on EH-CPU516 EH-CPU548 GT series RS232C type*2 EHV-CPU128 EHV-CPU64 Serial port EHV-CPU32 on CPU EHV-CPU16 GT707 *1: The settings vary according to the ports and communication methods.
Page 114
When connecting with EH-RS05 and a self-produced cable using EH-SIO unit Unit Wiring diagram GT series EH-CPU104A EH-CPU208A EH-CPU316A EH-CPU516 EH-CPU548 GT series RS232C type*2 Port 1 or Port 2 of EH-SIO EHV-CPU128 EHV-CPU64 EHV-CPU32 EHV-CPU16 GT707 *1: The settings vary according to the ports and communication methods. Refer to the above settings for communication conditions.
Page 115
When connecting with self-produced cable using a RJ45 connector RJ45 modular port Port 1 viewed from the front of the module (socket side) Link I/F Wiring diagram GT series EH-CPU104A EH-CPU208A Port 1 or EH-CPU316A Port 2 on EH-CPU516 GT series...
Page 116
When connecting with a self-produced cable using a RJ45 connector with EH-SIO unit * Refer to the above drawing of RJ45 modular port. Unit Wiring diagram GT series EH-CPU104A EH-CPU208A EH-CPU316A EH-CPU516 EH-CPU548 GT series RS232C type*2 Port 1 or...
9.1.2 RS422 Connection * Refer to the above drawing of RJ45 modular port. When connecting with a self-produced cable Link I/F Wiring diagram GT series EH-CPU104A EH-CPU208A Port 1 on EH-CPU316A EH-CPU516 EH-CPU548 RS422/ RS485 type EHV-CPU128 EHV-CPU64 Serial port...
9.1.3 RS485 Connection When connecting with a self-produced cable * Refer to the above drawing of RJ45 modular port. Link I/F Wiring diagram GT series EH-CPU104A EH-CPU208A Port 1 EH-CPU316A on CPU EH-CPU516 EH-CPU548 RS422/ RS485 type EHV-CPU128 EHV-CPU64 Serial port...
9.2 MICRO-EH Series PLC model selection Select "Hitachi EH/EHV series". Usable devices Bit/Word Device Memo External input X 00000~X 4FF95 External output Y 00000~Y 4FF95 Internal output R 000~R FFF Internal output WR 0000.0~WR FFFF.F CPU link L 00000~L 73FFF Internal output WN 00000.0~WN 1FFFF.F Data area...
Page 120
Communication Parameters Settings The example of communication settings of GT and PLC is shown below. Setting Values for GT (Set in the configuration setting of GTWIN.) Item Setting Baud Rate 19200bps Data Length Stop Bits Parity Bit Even Setting Values for PLC Setting for MICRO-EH Port1 The settings for the dip switches and the special internal output are required.
9.2.1 RS232C Connection When connecting with EH-RS05 and a self-produced cable MICRO-EH series PLC type Link I/F Wiring diagram GT series GT series RS232C type*2 14 points 20 points 23 points Port 1 on 28 points 40 points 64 points GT707 *1: The settings vary according to the ports and communication methods.
Page 122
When connecting with self-produced cable using a RJ45 connector RJ45 modular port Port 1 viewed from the front of the module (socket side) MICRO-EH series PLC type Link I/F Wiring diagram GT series GT series RS232C type*2 14 points 20 points 23 points...
9.3 Web Controller Series PLC model selection Select "Hitachi EH/EHV series". Usable devices Bit/Word Device Memo External input X 00000~X 4FF95 External output Y 00000~Y 4FF95 Internal output R 000~R FFF Internal output WR 0000.0~WR FFFF.F CPU link L 00000~L 73FFF Internal output WN 00000.0~WN 1FFFF.F Data area...
Page 124
Communication Parameters Settings The example of communication settings of GT and PLC is shown below. Setting Values for GT (Set in the configuration setting of GTWIN.) Item Setting Baud Rate 19200bps Data Length Stop Bits Parity Bit Even Setting Values for PLC Setting for Web Controller Serial port For setting the serial port, start a Web browser on a PC, and access the page of the system configurator...
9.3.1 RS232C Connection When connecting with EH-RS05 and a self-produced cable PLC type Link I/F Wiring diagram GT series GT series RS232C type*1 10 points (EH-WD10DR) Serial port on CPU 23 points (EH-WD23DR) GT707 *1: This is for RS232C type of GT01/GT02/GT02L/GT03-E/GT05/GT11/GT12/GT21/GT32/ GT32-E/GT703/GT704.
Page 126
When connecting with self-produced cable using a RJ45 connector RJ45 modular port Port 1 viewed from the front of the module (socket side) PLC type Link I/F Wiring diagram GT series GT series RS232C type*1 10 points (EH-WD10DR) Serial port...
9.3.2 RS422 Connection When connecting with self-produced cable using a RJ45 connector * Refer to the above drawing of RJ45 modular port. PLC type Link I/F Wiring diagram GT series 23 points Serial port RS422/ (EH-WD23DR) on CPU RS485 type...
9.3.3 RS485 Connection When connecting with self-produced cable using a RJ45 connector * Refer to the above drawing of RJ45 modular port. PLC type Link I/F Wiring diagram GT series Serial 23 points RS422/ port on (EH-WD23DR) RS485 type 9-20...
10.3 Modbus (RTU Mode) for Temperature Control Unit, PLC model selection Device setting: Start No. *****0 Select "Modbus (RTU mode | Temperature control unit, etc) Overview of communication Only function codes "03" and "06" which are the command to read/write the contents of the holding registers are used.
Page 133
Function code Function code 03 (Read Holding Registers) Command Function Starting Starting No. of read No. of read Error check Error check GT unit No. code 00(H) 01(H) (Higher) (Lower) (Higher) (Lower) 1 byte 1 byte 1 byte 1 byte 1 byte 1 byte 1 byte...
10.4 Connection Method (Example) RS232C connection Wiring diagram GT series GT series RS232C type*1 *2 GT707 *1: Although nos.6 and 7 of the models except GT01 are RS/CS, they can be used in the above connection. *2: This is for RS232C type of GT01/GT02/GT02L/GT03-E/GT05/GT11/GT12/GT21/GT32/ GT32-E/GT703/GT704.