Sign In
Upload
Manuals
Brands
YASKAWA Manuals
Control Systems
YASNAC i80
YASKAWA YASNAC i80 Manuals
Manuals and User Guides for YASKAWA YASNAC i80. We have
1
YASKAWA YASNAC i80 manual available for free PDF download: Maintenance Manual
YASKAWA YASNAC i80 Maintenance Manual (227 pages)
FOR MACHINE TOOLS
Brand:
YASKAWA
| Category:
Control Systems
| Size: 5.83 MB
Table of Contents
Table of Contents
6
Outline "C
11
Ospindle Does Not Rotate
11
Componens and Interconnections
12
Component Arrangement
12
NC Major Components
21
JZNC-IRK22 Module
29
Option Modules
53
Combination of Servopack (SC Type) and Motor
58
Spindle Drive Unit
64
Maintenance Unit
66
Routine Inspection Schedule
67
2 ROUTINE INSPECTIONSCH Edu LE
68
Routine Inspection
68
Tape Reader Maintenance
69
Control Panel
70
AC Servomotor Check
72
Battery ".00 "O""Oo
73
Battery Check
73
Battery Replacement
73
3 Mal NT en an Cel NSTRUME NTS
77
Measuring Instruments
78
4 Troubleshooting
79
Trouble Identification
81
Recognition of Trouble Status
81
Recognition of NC System
82
NC System Software
83
Troubleshooting by Alarm Codes
87
Display Method
87
Alarm Indication Job
89
Alarms 0010 and 0011 (Parity Error)
92
ALARMS Ooioandoo1L (PARITY ERROR)
92
Alarms 0016, 0017, 0018, 9016, 9017 and 9018 (RS-232C Error)
93
Setting of Applicable Interface
94
Settings of Serial Interface
95
Connection Cable (A) for Terminal Connection RS-232C Interface
96
Alarm 1099 (Temperature Alarm Inside the Panel)
98
Alarms 2061 to 2068 (Zero Point Return Area Error)
99
Alarms 2071 to 2078, 2081 to 2088 (Reference Point Return Area Error)
100
Alarms 2101 T02108(P-Set Error)
101
Alarms 2101 to 2108 (P-Set Error)
101
Alarm 3000 (Servo Unready)
102
Alarm 3001 (Control Not Ready)
102
0Alarm3002 (Emergency Stop)
103
Alarm 3002 (Emergency Stop)
103
Alarms 3041 to 3048 (Excessive Position Lag)
104
Alarms 3051 to 3054 (Excessive Position Lag)
105
Alarms 3061 to 3068 (Motor Overload)
106
Alarms 3081 to 3088 (PG Disconnection Error)
106
Alarms 3121 to 3128 (Excessive Speed)
107
ALARMS 3091 to 3094 (SPINDLE PG DISCONNECTION ERROR) .O.-"Ooo
107
17,-Alarms 3141 to 3148 (Prevention of Uncontrolled Running)
108
Alarms 3161 to 3168 (Absolute Errors)• 00
108
Alarms 3181 to 3188 (Position Errors)
109
Alarms 3201 to 3208 (Servodrive Unit Communication Errors)
109
Alarms 3301 to 3305 (Overcurrent)
110
Alarms 3311 to 3315 (MCCB Trip)
110
Alarms 3321 to 3325 (Regenerative Error)
110
Alarms 3351 to 3355 (Heat Sink Overheat)
111
Alarms 3321 to 3325 (Regenerative Error)
111
Alarms 3341 T03345 ( Undervoltage )
111
Alarnis 3331 to 3335 (Overvoltage)
111
Alarms 3361 to 3365 (Wire Break in Current Instruction Cable)
112
Alarms 3371 to 3375 (Open Phase)
112
Cable)"".".• "". C.". O
112
Troubleshooting Without Alarm Codes
113
Power Cannot be Supplied 00
113
Self-Diagnosis Functions
114
Solution to Errors Detected in Self-Diagnosis .-. -. O
114
Details of Function
115
Memory Check
115
CMOS Check
115
ROM Check
116
RAM Check
117
LED Display
119
Processing Program Area, Initialization Check
120
Expanded Memory Consistency Check
121
Axis Configuration Parameter Consistency Check
121
Overheat Detection
122
Battery Alarm Detection
122
CRT Screen Does Not Display
123
Handle Mode Operation Faulty• Oooc. O
123
Manual Jog Mode Operation Faulty
125
Manual Rapid Mode Operation Faulty
127
Manual Zero Return Operation Faulty
129
Cycle Start Failure .00C
130
Operation Is Not Available with GO1, G02, or G03
131
Spindle Does Not Rotate
132
9" CRT Screen Is Dark
133
Edit Does Not Function
134
Fin Wait Occurs by Spindle Related Instruction
135
Skip Function (G31) Operation Failure
136
Tape Mode Does Not Function .Occc
137
Check at Power Supply Voltage
138
Power Supply Voltage Check C
138
Indication of Lamp of Power Supply Unit
139
Check DC Power Supply Voltage
139
Status Display by Self-Diagnosis Function (DGN)
140
Outline of Display
140
Displaying Input/Output Signals
141
Displaying Input/Output Signals• "". O. C
141
5 ADJUST ME NTSUPON Lnstallatl on
145
Error Pulse Display Screen
151
Module/Unit Replacement Procedure
153
NC Rack
154
Power Supply Unit
154
Model JANCD-FC1OOC
156
Model JANCD-FC190-1
158
Installation
158
Model JANCD-FC200
160
Model JANCD-FC21O-1
162
Model JANCD-FC222/FC224
164
Model JANCD-FC230B
166
Installation
166
Model JANCD-FC242
168
Model JANCD-FC300B-3
170
Model JANCD-FC250
172
Installation
172
Installation
178
Installation
184
Back Board
190
Installation
190
11-Slot Back Board
192
Machine Control Station
194
9" AMGC Control Panel
194
Installation
197
Keyboard (Model Df8203788)
200
14" ACGC Control Panel
201
Installation
203
14" Color Graphic CRT Unit
204
Setting and Adjustment of each Module
207
Operations of Fixed Files
213
Types of Fixed Files
214
Display and Writing of Fixed Files
215
Advertisement
Advertisement
Related Products
YASKAWA yasnac i80m
YASKAWA VIPA IM 053EC
YASKAWA IM 053PN
YASKAWA iQpump Micro CIMR-PW Series
YASKAWA Motoman ArcWorld IV-6300 XHD TR3C
YASKAWA IM 053MT
YASKAWA IM 053IP
YASKAWA iC9200 Series
YASKAWA iC9216M-FSoE
YASKAWA iC9216M-EC
YASKAWA Categories
Controller
DC Drives
Servo Drives
Robotics
Control Unit
More YASKAWA Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL