Sign In
Upload
Manuals
Brands
NEMA Manuals
Industrial Equipment
MG 1-2011
NEMA MG 1-2011 Industrial AC Motor Manuals
Manuals and User Guides for NEMA MG 1-2011 Industrial AC Motor. We have
1
NEMA MG 1-2011 Industrial AC Motor manual available for free PDF download: Information Manual
NEMA MG 1-2011 Information Manual (78 pages)
General Purpose Industrial AC Small and Medium Squirrel-Cage Induction Motor Standards
Brand:
NEMA
| Category:
Industrial Equipment
| Size: 1.54 MB
Table of Contents
Table of Contents
3
Foreword
7
1 Purpose
8
2 Scope
8
3 Definitions
8
4 Classification of Degrees of Protection Provided for Enclosures for Rotating Motors
10
Single Characteristic Numeral
10
Supplementary Letters
10
Letters Following Numerals
10
Letters Placed Immediately after the Letters IP
10
Degrees of Protection-First Characteristic Numeral
10
Degrees of Protection-Second Characteristic Numeral
11
5 Methods of Cooling
11
Arrangement of the IC Code
11
6 Mechanical Vibration-Measurement, Evaluation, and Limits of Ac Medium Motors
11
7 Small (Fractional) and Medium (Integral) Motors Ratings
11
Voltages
11
Frequencies
12
Horsepower and Speed Ratings
12
Small Induction Motors
12
Single-Phase Medium Motors
12
Polyphase Medium Induction Motors
12
Basis of Single-Phase Horsepower Rating
12
Horsepower Ratings of Multispeed Motors
12
Constant Horsepower
12
Constant Torque
12
Variable Torque
12
Code Letters (for Locked-Rotor Kva)-Nameplate Marking
13
Nameplate Temperature Ratings for Alternating-Current Small Motors
13
Nameplate Marking for Small Single-Phase and Polyphase Motors
13
Dual Voltage, Dual Frequency, and Dual Speed Motors
13
Nameplate Marking for Medium Single-Phase and Polyphase Induction Motors
14
Additional Nameplate Information for All Motors
14
8 Dimensions-Ac Small (Fractional) and Medium (Integral) Motors
15
System for Designating Frames
15
Small Motors
15
Medium Motors
15
Frame Assignments
16
Lettering of Dimension Sheets
16
Tolerances for Shaft Runout
16
Grounding Means for Field Wiring
16
9 Tests and Performance-Ac Small and Medium Motors
16
Routine Tests for Polyphase Medium Induction Motors
16
High-Potential Test Voltages for Induction Motors [MG 1-12.3]
16
Test Methods
17
Performance Characteristics
17
Torque Characteristics of Single-Phase General-Purpose Induction Motors
17
Breakdown Torque of Single-Phase Motors
17
Locked-Rotor Torque of Single-Phase Small Motors
17
Locked-Rotor Torque of Single-Phase Medium Motors
17
Pull-Up Torque of Single-Phase Medium Motors
17
Locked-Rotor Current Characteristics of Single-Phase and Polyphase General-Purpose Induction Motors
17
Locked-Rotor Current of Single-Phase Small Motors, Designs N, O,And General Purpose
17
Locked-Rotor Current of Single-Phase Medium Motors, Designs L and M
17
Locked-Rotor Current of 3-Phase 60-Hertz Small and Medium Squirrel-Cage Induction Motors Rated at 230 Volts
18
Torque Characteristics of Polyphase General-Purpose Induction Motors
18
Breakdown Torque Characteristics of Polyphase Small Motors
18
Locked-Rotor Torque of Single-Speed Polyphase Squirrel-Cage Medium Motors with Continuous Rating
18
Breakdown Torque of Single-Speed Polyphase Squirrel-Cage Medium Motors with Continuous Ratings
18
Pull-Up Torque of Single-Speed Polyphase Squirrel-Cage Medium Motors with Continuous Ratings
18
Temperature Rise for Small and Medium Single-Phase and Polyphase Induction Motors
18
Variations from Rated Voltage and Rated Frequency
19
Running
19
Starting
19
Voltage Unbalance
19
Variation from Rated Speed
19
Variation from Nameplate Amperes-Alternating-Current Medium Motors
19
Occasional Excess Current
19
Stall Time
20
Service Factor of Alternating-Current Motors
20
General-Purpose Alternating-Current Motors of the Open Type
20
Overspeeds for Squirrel-Cage Motors
20
General Purpose Squirrel-Cage Induction Motors
20
General-Purpose Design a and B Direct-Coupled Squirrel-Cage Induction Motors
20
Machine Sound (Medium Induction Motors)
21
General
21
Sound Measurement
21
Sound Power Levels of Polyphase Squirrel-Cage Induction Motors at no Load
21
Sound Power Levels of Polyphase Squirrel-Cage Induction Motors at Rated Load
21
Number of Starts
21
Thermal Protection of Medium Motors
22
Winding Temperature
22
Overtemperature Protection of Medium Motors Not Meeting the Definition of "Thermally Protected
22
Type 1-Winding Running and Locked Rotor Overtemperature Protection
22
Type 2-Winding Running Overtemperature Protection
23
Type 3-Winding Overtemperature Protection, Nonspecific Type
23
Efficiency
23
Determination of Motor Efficiency and Losses
23
Efficiency of Polyphase Squirrel-Cage Medium Motors with Continuous Ratings
24
Efficiency Levels of Energy Efficient Polyphase Squirrel-Cage Induction Motors
24
Efficiency Levels of Premium Efficiency Electric Motors
24
Effects of Load on Motor Efficiency
24
10 Application Data-Ac Small and Medium Motors
25
Service Conditions
25
11 Application Considerations for Constant Speed Design a and B Induction Motors Used on a Sinusoidal Bus with Harmonic Content
25
Efficiency
25
Derating for Harmonic Content
25
Harmonic Voltage Factor (HVF) Defined
25
Power Factor Correction
26
12 Application Considerations for General Purpose Design a and B Induction Motors Used with Adjustable-Voltage or Adjustable-Frequency Controls or both
26
Torque
26
Motor Torque During Operation below Base Speed
26
Torque Derating at Reduced Speeds
26
Motor Torque During Operation above Base Speed
26
Current
27
Running Current
27
Starting Current
27
Efficiency
27
Maximum Safe Operating Speeds
27
Sound
27
Resonances, Sound, Vibration
28
Voltage Stress
28
Power Factor Correction
28
Operation in Hazardous (Classified) Locations
28
Table of Contents
29
Alternating Current Medium Motor
34
Motors Covered by this Guide
34
Degrees of Protection Indicated by the First and Second Characteristic Numerals
35
Horsepower and Speed Ratings, Small Induction Motors
36
Typical Methods of Cooling (IC Code)
36
Unfiltered Vibration Limits
36
Horsepower and Speed Ratings, Single-Phase Medium Motors
37
Horsepower and Speed Ratings, Polyphase Medium Induction Motors
38
Breakdown Torque for Induction Motors
39
Breakdown Torque for Permanent-Split Capacitor Motors
40
Typical Characteristics and Applications of Fixed Frequency Small and Medium Ac Squirrel-Cage Induction Motors
41
Code Letters (for Locked-Rotor Kva)-Nameplate Marking
42
Medium Machine Frame Numbering
42
Frame Designations for Polyphase, Squirrel-Cage, Designs a and B
43
Horizontal and Vertical Motors, 60 Hertz, Class B Insulation System
43
Open Type, 1.15 Service Factor, 575 Volts and Less
43
Frame Designations for Polyphase, Squirrel-Cage, Designs a and Bhorizontal and Vertical Motors, 60 Hertz, Class B Insulation System, Open Type, 1.15 Service Factor, 575 Volts and Less
43
Frame Designations for Single-Phase, Design L, Horizontal and Vertical Motors, 60 Hertz, Class B Insulation System, Open Type, 1.15 Service Factor, 230 Volts and Less
43
Frame Designations for Polyphase, Squirrel-Cage, Design C
44
Frame Designations for Polyphase, Squirrel-Cage, Design C, Horizontal and Vertical Motors, 60 Hertz, Class B Insulation System, Totally Enclosed Fan-Cooled Type, 1.0 Service Factor, 575 Volts and Less
45
Lettering of Dimension Sheets
46
Dimensions for Alternating-Current Foot-Mounted Motors with Single Straight-Shaft Extension
47
Shaft Extensions and Key Dimensions for Alternating-Current Foot
49
Dimensions for Type Dflange-Mounting Foot or Footless
51
Alternating-Current Motors
52
Dimensions for Type Fc Face Mounting for Accessories on End Opposite Drive End of Alternating-Current Motors
52
Minimum Size Grounding Conductor Termination
52
Tolerances for Type C Face Face-Mounting and Type D Flange- Mounting Motors, Maximum Eccentricity of Mounting Rabbet
52
Locked-Rotor Current of Single-Phase Small Motors, Designs O and N
53
Locked-Rotor Torque of Single-Phase Medium Motors
53
Locked-Rotor Torque of Single-Phase Small Motors
53
Locked-Rotor Current of 3-Phase 60-Hertz Small and Medium Squirrel-Cage Induction Motors Rated at 230 Volts
54
Locked-Rotor Current of Single-Phase Medium Motors, Designs L and M
54
Locked-Rotor Torque of Design a and B Motors
55
Locked-Rotor Torque of Design C Motors
55
Breakdown Torque of Design a and B Motors
56
Breakdown Torque of Design C Motors
56
Pull-Up Torque of Design a and B Motors
57
Pull-Up Torque of Design C Motors
58
Temperature Rise for Small and Medium Single-Phase and Polyphase Induction Motors
59
Induction Motors
59
Overspeeds for Squirrel-Cage Motors
60
Service Factors of General-Purpose Alternating-Current Motors of the Open Type
60
Continuous Speed Capability for General-Purpose Squirrel-Cage
61
Continuous Speed Capability for General-Purpose Design a and Bdirect Coupled (Ts Shaft for Motors above the 250 Frame Size) Squirrel-Cage Induction Motors
62
MAXIMUM A-WEIGHTED SOUND POWER LEVELS, L Wa (Db), at NO-LOAD
63
Incremental Expected Increase over No-Load Condition, in A-Weighted Sound Power Levels L
64
Wa (Db) , for RATED LOAD CONDITION
64
Reference Load Wk
64
Specified Temperature for Winding Resistance Correction When Rated Load Temperature Is Not Measured
65
Winding Temperature under Locked-Rotor Conditions
65
Winding Temperatures under Running Load Conditions
65
Efficiency Levels
66
Full-Load Efficiencies of Energy Efficient Motors
67
FULL-LOAD EFFICIENCIES for 60 Hz NEMA PREMIUM® EFFICIENCY ELECTRIC MOTORS RATED 600 VOLTS or LESS (RANDOM WOUND)
68
Full-Load Efficiencies for 60Hz Nema Premium® Efficiency Electric Motors Rated 5000 Volts or Less
69
Full-Load Efficiencies for 50 Hz Nema Premium Efficiency Electric Motors Rated 600 Volts or Less (Random Wound)
70
Maximum Safe Operating Speed for Standard Design a and B Direct Drive (Ts Shaft for Frames over 250) Squirrel-Cage Induction Motors
72
Advertisement
Advertisement
Related Products
NEMA Categories
Tent
Grill
Industrial Equipment
Switch
More NEMA Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL