Sign In
Upload
Manuals
Brands
NCR Manuals
Barcode Reader
74 OFX (7874)
NCR 74 OFX (7874) Manuals
Manuals and User Guides for NCR 74 OFX (7874). We have
1
NCR 74 OFX (7874) manual available for free PDF download: User Manual
NCR 74 OFX (7874) User Manual (268 pages)
NCR RealScan 74 OFX (7874)
Brand:
NCR
| Category:
Barcode Reader
| Size: 3.61 MB
Table of Contents
User Guide
1
Table of Contents
4
Chapter 1: Product Information
17
Available Models
18
Features and Options
18
Bi-Optic Scanning
18
Communications Protocol
20
Autodiscrimination
20
Remote Compact Display
21
Dual Peripheral RS232 Ports
21
Usb
23
Firmware Flashing
23
Operator Interface
24
Voice Messages
24
Power Supply
25
Pacesetter
25
PACESETTER Plus
26
Pacesetter III
27
Parameter Programming
27
Scan Doctor Diagnostics
27
Power-On Wellness Check
27
Ongoing Wellness Check
28
Service Diagnostics
28
Soft Power Down/Power up
28
Chapter 2: Site Preparation
29
Customer Responsibilities
29
Preparing the Site
30
Weight
31
Scanner Dimensions
31
Checkstand Cutout
32
Realscan 7874-3000/3020 (35.3 CM / 13.9 Inch)
32
Realscan 7874-3000/4Xxx/5Xxx (15.7 Inch)
33
Realscan 7874-3000 When Third-Party Scale Attached
33
Realscan 7874-4Xxx/5Xxx with F030 / K002 (40.6 CM / 16 Inch)
34
Realscan 7874-4Xxx/5Xxx with 7874-K200 (50.8 CM / 20 Inch)
35
With Side Rails
35
No Side Rails
36
Realscan Checkstand Wiring
37
Power Considerations
38
Power Transient Protection
38
Cable Connections
38
Service Clearance
39
Environmental Considerations
40
Ventilation Requirements
40
Realscan 25 Compact Display Dimensions
41
Chapter 3: Installation
43
Installation Steps
44
Step 1: Verify Installation Preparation
44
Package Contents
44
Reporting a Damaged Unit
44
Step 2: Cable Installation Preparation
45
Step 3: Sensormatic® Coil Installation
46
Step 4: Cable Connection
51
Step 5: Realscan 74 Installation in Checkstand Cutout
53
Step 6: Top Plate Alignment Verification
54
Step 7: Scale Calibration
54
Perform the Calibration Procedure
55
1. Increasing Load Test
63
2. Over-Capacity Test
63
Decreasing Load Test
64
Shift Test
65
Securing the Calibration Switch
66
Step 8: Sensormatic® Deactivation Setup
68
Sensormatic Tag Deactivation
68
Sensormatic® Online Offline Indication
68
Specific Function Programming
70
Power-Up the System
74
Check Sensormatic® Deactivation System
75
Step 9: Operational Unit Verification
76
NCR Realscan 74 Scanner-Only Models
76
NCR Realscan 74 Scanner/Scale Models
76
Realscan 74 Power-On Wellness Check
77
Checkout Reading Operation
77
Flash Latest Firmware
77
Special Host Terminal Connections
78
Scanner Connected to IBM Terminals
78
SNI Beetle Host Terminal
78
Peripheral Connections
79
Metrologic Hand-Held Scanner
79
Programming the Metrologic Hand-Held Scanner if Connected through the Auxiliary RS232 Port
80
Programming the Realscan 74
83
NCR Realscan 2357 and Hand-Held Products (Honeywell) Type Hand-Held Scanner
84
Programming Hand-Held Products Scanner if Connected through the Auxiliary RS232 Port
84
Programming the Realscan 74
85
Programming Realscan 2357 Hand-Held Scanner if Connected through the USB Peripheral Port
86
NCR Realscan 2356 and Symbol (Motorola) Type Hand-Held Scanner
87
Programming the Realscan 2356 Hand-Held if Connected through the Auxiliary RS232 Port
87
Programming the Realscan 74
88
Programming Realscan 2356 Hand-Held Scanner if Connected through the USB Peripheral Port
89
NCR Realscan 2356-4278 Wireless Hand-Held Scanner
91
Programming the Realscan 2356 Wireless Hand-Held Scanner
91
Programming the Realscan 74
92
Chapter 4: Operation
93
System Components
94
Operator Display Panel
94
Motion Detector
94
Scan Adviser Status Indicator
95
Scale Zero Button
96
Volume Adjust Button
96
Manual Deactivation Button
97
Remote Compact Display
98
Scan Adviser LED Scanner State Indicators
99
Speaker
100
Vertical and Horizontal Scan Windows
100
Top Plate
101
Label Orientation
102
Active Scan Zone
102
Multiple Reads
102
Operating Instructions
103
Turning the Realscan 74 on and off
103
Scanner Only Model
103
Scanner/Scale Model
103
Scanning Procedure
104
Weighing Procedure
104
Sensormatic® Security Tag Deactivation Procedure
105
Normal Operation
105
Manual Deactivation
106
Adjusting the Good Read Tone
106
Not-On-File Error
107
Cleaning Instructions
108
Scanner Body
108
Vertical Scan Window
108
Top Plate and Horizontal Scan Window
108
Chapter 5: Programming
109
Programming Description
110
Creating the Program
110
Enter the Program
110
Write the Program
110
Save the Program
111
Programming Tags
111
Abort
111
Default
112
End
113
Hex 0-Hex F
113
Program Mode
113
Save and Reset
114
Speak Bar Codes Currently Enabled
114
Indication
114
Speak Scanner Serial Number
114
Program Entry Procedure
115
Enter All Parameters
115
Enter Specific Parameters (Shortcut Method)
117
Parameter Defaults
119
Programming Tips
125
Program Parameter Descriptions
126
Communications Protocol
126
IBM Slot Scanner
126
Ibm Usb
126
Ncr (Rs232 Usb)
126
Rs232
127
Good Read Tone
127
Tone Frequency (Hertz)
128
Tone Length (Milliseconds)
128
Tone On/Off
128
Tone Volume
128
Not-On-File Volume
129
Timers
130
Lockout Time
130
900Ms Lockout Timer Restart Limit
131
Active Time
131
Restart Lockout Timer
131
Bar Codes-1
132
Upc/Ean
132
Add-On Bar Codes
133
Add-On Code Length
133
Extend UPC-A to EAN-13
133
Extend UPC-E to UPC-A
133
Send Data
133
Set 2 Tag Label
133
Bar Codes-2
134
Check Digit Present
134
Code 39
134
Full ASCII
134
Transmit Check Digit
134
Allow 1- or 2-Character Tags
135
Code 39 Tone
135
Code 39 Halves Enable
136
Code 39 Stitch Enable
136
Tone Frequency
136
Tone Length
136
Check Digit Length1 and Length2
137
Code 39 Stitch Check Digit
137
Minimum Segment Size
137
Overlap Characters
137
Scans Required
137
Bar Codes-3
138
Interleaved 2 of 5
138
Bar Code Length
139
Check Digit Present
139
Transmit Check Digit
139
Value 1 and 2
139
Interleaved 2 of 5 Check Digit Length1
140
Interleaved 2 of 5 Tone
140
Tone Frequency
140
Tone Length
140
Enable Interleaved 2 of 5 Stitching
141
Interleaved 2 of 5 Check Digit Length2
141
Minimum Segment Size
141
Overlap Characters
141
Scans Required
141
Bar Codes-4
142
Code 128
142
Code 128 Tone
142
Tone Length
142
Code 128 Stitch Enable
143
Minimum Segment Size
143
Overlap Characters
143
Scans Required
143
Tone Frequency
143
Bar Codes-5
144
Emulation Mode
144
GS1 Databar Enable
144
Scans Required on GS1 Databar-14
144
Scans Required on GS1 Databar-E
144
UCC–128 Emulation Mode
145
Bar Codes-6
145
Codabar Check Digit
145
Codabar Check Digit Transmission
145
Codabar Tone
146
Codabar Tone Frequency
146
Codabar Tone Length
146
Codabar Halves
147
Codabar Stitch
147
Number of Codabar Scans Required
147
Bar Codes-7
147
Pharmacode Check Digit Transmission
147
Label Identifiers
148
Identifier Type
148
Common Byte 1 and Common Byte 2
149
Bar Code Type
150
Common Byte
150
Unique Identifier
150
RS232 Parameters 1
151
Baud Rate
151
Parity
151
Handshake
152
Stop Bits and Character Length
152
RS232 Parameters 2
153
BCC Options
153
Check Digit
154
Interface Control
154
RS232 Prefix Byte
154
ASCII Code
155
Prefix Byte
155
RS232 Terminator Byte
155
ASCII Code
156
Terminator Byte
156
RS232 Communications Options
156
Message Delay
157
Scanner/Scale Format
157
Good Weigh Tone
158
Normal or Eavesdrop Mode
158
Scale Parameters
158
Model
158
IBM Address
159
Miscellaneous Parameters
159
Host Tone Control
159
IBM Retransmit Control
159
Enable/Disable Voice Messages
160
IBM-485 / IBM-USB Tag Data Format
161
Number System Character Parameter
161
Dual Cable Interface
162
Avery Scale Emulation
162
Programming Worksheets
163
Communications Protocol
163
Good Read Tone
164
Timers
165
Bar Codes-1
166
Bar Codes-2
167
Bar Codes-3
168
Bar Codes-4
169
Bar Codes-5
170
Bar Codes-6
171
Bar Codes-7
171
Label Identifiers
172
Number System Character
173
Sensormatic Deactivation Tone Frequency
173
Sensormatic Deactivation Tone Pulse
173
RS232 Parameters 1
174
RS232 Parameters 2
175
RS232 Prefix Byte
176
RS232 Terminator Byte
176
RS232 Communications Options
177
Scale Parameters
177
Miscellaneous Options
178
Code 128 Tone Length
178
Miscellaneous Parameters
178
Code 128 Minimum and Maximum Tag Length
179
Code 128 Stitch
179
Code 128 Tone
179
Code 128 Tone Frequency
179
Code 39 Tone
180
Code 39 Tone Frequency
180
Code 39 Tone Length
180
Code 39 CD Length1
181
Code 39 Halves
181
Code 39 Intercharacter Gap Check
181
Code 39 Quiet Zone
181
Code 39 Stitch
181
Code 39 CD Length2
182
Code 39 Minimum and Maximum Length
182
Interleaved 2 of 5 Tone Length
182
Interleaved 2 of 5 Tone Frequency
183
Interleaved 2 of 5 Tone
183
Interleaved 2 of 5 CD Length1
183
Interleaved 2 of 5 CD Length2
184
Interleaved 2 of 5 Scans Required
184
Interleaved 2 of 5 Overlap
184
Interleaved 2 of 5 Minimum Segment Size
185
Enable/Disable Interleaved 2 of 5 Partials
185
GS1 Databar Tone Length
185
GS1 Databar Tone Frequency
186
GS1 Databar Tone
186
GS1 Databar-E AI 93 to Code 39 Tag Data Conversion
186
GS1 Databar-E AI 94 to UCC-128 Tag Data Conversion
186
GS1 Databar-E AI 94 to Code-128 Tag Data Conversion
186
GS1 Databar-E AI 95 to Interleaved 2 of 5 Tag Data Conversion
187
Codabar Tone Length
187
Codabar Tone Frequency
187
Codabar Tone
188
Codabar Halves
188
Codabar Stitch
188
Codabar Require Start/Stop Match
188
Codabar Require Quiet Zones
188
Codabar Start/Stop Transmission
189
Codabar Hard Correlation
189
Number of Codabar Overlaps Required
189
Number of Codabar Scans Required
189
Number of Coupon Scans Required
190
Number of UPC/EAN Scans Required
190
Number of Code 39 Scans Required
190
Number of Code 128 Scans Required
191
Number of Code 39 Overlaps Required
191
Number of Minimum Code 39 Characters in Code 39 Partial
191
Number of Code 128 Overlaps Required
191
Number of Minimum Interleaved 2 of 5 Characters in Interleaved 2 of 5 Partial
192
Number of Minimum Code 128 Characters in Code 128 Partial
192
Command-Type Disable
192
Ignore RS232 Commands from POS
192
Enable UPC NS5 Coupon
193
GS1 Databar AI 8110 Coupons
193
EAN-13 98 Coupons
193
Expand E to EAN-13 Directly
193
EAN–13 99 Coupons
193
Checkpoint Interlock
194
Scanner Power-On State
194
ASCII Code Chart
194
Special Programming
195
Disable Soft Defaults
195
Enable Soft Defaults
195
Set Current Parameters to Default Values
195
Check Digits on Price Fields
196
Convert UPC-E Tags to EAN-13 Tags
196
Mandatory 4 Digit Price Check
196
Mandatory 5 Digit Price Check
196
Enable/Disable Code-128 Partials
197
Good Read Tone
197
GS1 Databar
198
GS1 Databar-14
198
GS1 Databar-14 Stacked
198
Enable/Disable GS1 Databar
199
GS1 Databar-Expanded
199
GS1 Databar-Expanded Stacked
199
Send GS1 Databar-14 as EAN-13 Data
199
Terminal Coupon Interface Parameters
200
Terminal Coupon Select 1
200
Terminal Coupon Select 2
201
Voice Messages-Enable/Disable
201
Voice Volume
202
Volume Adjust Button
202
Enable/Disable Volume Adjust Button
203
Volume Levels
203
Single Volume Adjust Bar Code
204
Firmware Flashing
204
Obtaining the Utility and New Firmware
204
Firmware Version
205
Firmware Flashing Procedure
206
Realscan Flash Drive Support
209
Flash Drive Prep Application Installation
209
NCR Realscan Flash Drive Prep Application
209
Diagnostic Download or Memory Dump
213
Realscan Flash Drive Prep Application Functions
213
Parameters Upload
216
Parameters Download
219
Firmware Upload
222
Firmware Download
225
Reset Tallies
228
Scanner Cloning
231
File Viewer
236
Chapter 6: Troubleshooting
241
Realscan 74 Diagnostics and Troubleshooting
242
Scale Diagnostics
242
Scale Troubleshooting Codes
243
Scanner Diagnostic Codes
244
Isolating Sensormatic® Problems
245
Appendix A: NCR Scanner Programming Tags
247
Appendix B: Additional Diagnostic Functions
259
Scale
259
Scanner Service Diagnostics
259
Appendix C: Obtaining Information Products
263
Advertisement
Advertisement
Related Products
NCR 7407-K013
NCR 7409-K302
NCR 7409 K303
NCR Orderman7
NCR Orderman7MSR
NCR Orderman7 Plus
NCR NCR Orderman7SC
NCR Orderman5
NCR OPTIC 5
NCR OPTIC 12
NCR Categories
Racks & Stands
Touch terminals
Printer
Scanner
Monitor
More NCR Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL