Sign In
Upload
Manuals
Brands
National Instruments Manuals
Controller
GPIB-232CT
National Instruments GPIB-232CT Manuals
Manuals and User Guides for National Instruments GPIB-232CT. We have
1
National Instruments GPIB-232CT manual available for free PDF download: User Manual
National Instruments GPIB-232CT User Manual (216 pages)
MicroGPIB RS-232 to IEEE-488 Controller
Brand:
National Instruments
| Category:
Controller
| Size: 3.52 MB
Table of Contents
Table of Contents
11
Description of the GPIB-232CT
20
Figure 1-1. the GPIB-232CT
20
Introduction
20
What Your Kit Contains
21
Optional Equipment
22
GPIB-232CT Specifications
23
Table 1-1. Electrical Characteristics
23
Table 1-2. Environmental Characteristics
23
Figure 1-2. the GPIB-232CT Front Panel
24
Table 1-3. Physical Characteristics
24
The GPIB-232CT Front Panel
24
Table 1-4. LED Descriptions
25
Figure 1-3. the GPIB-232CT Rear Panel
26
The GPIB-232CT Rear Panel
26
Figure 1-4. the RS-232 Connector and Signal Designations
27
The RS-232 Port
27
Figure 1-5. the GPIB Connector and Signal Designations
28
The GPIB Port
28
Choosing between S Mode or G Mode
29
Introduction
29
The GPIB-232CT Modes of Operation
29
Figure 2-1. Personal Computer Controlling a GPIB Plotter
30
Figure 2-2. a Serial Printer Connected to a GPIB Controller
30
Installation
31
Installation and Configuration in S Mode
31
Step 1: Inspection
31
Step 2: Verify the Voltage Requirement
32
Step 3: Configure the Operating Parameters
32
Figure 3-1. S Mode Switch Settings
33
Set Configuration Switches
33
Default Settings for Configuration Switch
34
Figure 3-2. Factory Default Settings for Switch U22
34
Step 4: Connect the Cables
35
Step 5: Power on the Unit
35
Example of a Programming Message
36
Programming in S Mode
36
Programming Message Format
36
Programming Messages
36
Example of a Programming Message with Data String
37
Function Names
37
How Messages Are Processed
37
Abbreviations for Arguments
38
Function Argument Delimiters
38
GPIB Address
38
Numeric String Argument
39
Status Information
39
GPIB Read and Write Termination Method (END and EOS)
40
Serial Port Error Handling
40
S Mode - Default Settings
41
Table 4-1. Serial Port Characteristics
41
Table 4-2. GPIB Characteristics
41
GPIB Functions
42
List of S Mode Functions by Group
42
Table 4-3. I/O Functions
42
Table 4-4. Bus Management Functions
42
Table 4-5. GPIB Initialization Functions
43
Table 4-6. Serial Poll Functions
43
Table 4-7. Low-Level Controller Functions
44
Table 4-8. Parallel Poll Functions
44
General Use Functions
45
Serial Port Functions
45
Table 4-10. General Use Functions
45
Table 4-9. Serial Port Initialization Functions
45
Alphabetical List of S Mode Functions
46
Table 4-11. GPIB-232CT Functions
46
Chapter 5 S Mode Functions
48
Points to Remember
48
Cac - Become Active Controller
50
Caddr - Change the GPIB Address of the GPIB-232CT
51
Clr - Clear Specified Device
53
CMD - Send GPIB Commands
55
Echo - Echo Characters Received from Serial Port
58
Eos - Change/Disable GPIB EOS Termination Mode
59
Table 5-1. Data Transfer Termination Methods
59
Eot - Enable/Disable END Message on GPIB Writes
62
Gts - Go from Active Controller to Standby
64
Ibcl - Enter Ibcl Operating System
66
ID - Identify System
68
Ist - Set or Clear Individual Status Bit
69
Loc - Go to Local
70
Onl - Place the GPIB-232CT Online/Offline
72
Pct - Pass Control
73
Ppc - Parallel Poll Configure
74
Ppu - Parallel Poll Unconfigure
76
Rd - Read Data
78
Rpp - Request (Conduct) a Parallel Poll
81
Rsc - Request System Control
83
Rsp - Request (Conduct) a Serial Poll
85
Rsv - Request Service/Set or Change Serial Poll Status Byte
88
Sic - Send Interface Clear
89
Spign - Ignore Serial Port Errors
91
Sre - Set (or Clear) Remote Enable
93
Stat - Return GPIB-232CT Status
94
Table 5-2. GPIB Status Conditions
95
Table 5-3. GPIB Error Conditions
96
Table 5-4. Serial Port Error Conditions
97
Tmo - Change or Disable Time Limit
100
Trg - Trigger Selected Device(S)
102
Wait - Wait for Selected Event
104
Table 5-5. Wait Mask Values
105
Wrt - Write Data
107
Xon - Change Serial Port XON/XOFF Protocol
110
Installation and Configuration in G Mode
112
Installation
112
Step 1: Inspection
112
Step 2: Verify the Voltage Requirement
113
Step 3: Configure the Operating Parameters
113
Set Configuration Switches
114
Figure 6-1. G Mode Switch Settings
114
Table 6-1. Primary Address Configurations
115
Example Settings for Configuration Switch
117
Step 4: Connect the Cables
117
Figure 6-2. Example Settings for Switch U22
117
Step 5: Power on the Unit
118
Programming in G Mode
119
Programming Messages
119
Programming Message Format
119
Example of a Programming Message
119
How Messages Are Processed
120
Function Names
120
Function Argument Delimiters
120
Abbreviation for Argument
120
Status Information
121
Communicating with the GPIB-232CT and the Serial Device
121
Address of the GPIB-232CT
121
Address of the Serial Device
121
Addressing Terminology
121
The GPIB-232CT and Serial Device as Listener
122
The GPIB-232CT and Serial Device as Talker
123
GPIB Read and Write Termination (END and EOS)
124
Serial Port Transmission
124
G Mode - Default Settings
125
Table 7-1. GPIB Characteristics
125
Table 7-2. Serial Port Characteristics
125
List of G Mode Functions by Group
126
GPIB Configuration Functions
126
Table 7-3. GPIB Configuration Functions
126
Serial Port Configuration Functions
127
General Use Functions
127
Table 7-4. Serial Port Configuration Functions
127
Table 7-5. General Use Functions
127
List of G Mode Functions in Alphabetical Order
128
Operation of the GPIB-232CT with a Serial Device
128
Table 7-6. GPIB-232CT Functions
128
Serial Poll
129
Service Request
129
Table 7-7. Serial Poll Response Byte
129
Parallel Poll
130
Trigger
130
Local
130
Control
130
Device Clear
131
Chapter 8 G Mode Functions
132
Points to Remember
132
Echo - Echo Characters Received from Serial Port
134
Eos - Change/Disable GPIB EOS Termination Mode
136
Table 8-1. Data Transfer Termination Methods
136
ID - Identify System
138
Onl - Place the GPIB-232CT Online/Offline
139
Spign - Ignore Serial Port Errors
140
Spset - Change Serial Port Parameters
141
Srqen - Enable/Disable Setting of SRQ
143
Table 8-2. SRQ Mask Bits
143
Stat - Return GPIB-232CT Status
145
Table 8-3. GPIB-232CT Status Conditions
146
Table 8-4. GPIB Error Conditions
147
Table 8-5. Serial Error Conditions
148
Xon - Change Serial Port XON/XOFF Protocol
151
Multiline Interface Messages
153
Multiline Interface Messages
156
Interface Message Reference List
156
Status Bits
159
GPIB Error Codes
164
Serial Port Error Codes
168
Appendix C the Serial Connection
170
Rs-232C
170
Interfacing the GPIB-232CT to a DCE
172
Figure C-1. DTE-To-DCE Cable Configuration
172
Figure C-2. Minimum DTE-To-DCE Cable Configuration
173
Interfacing the GPIB-232CT to a DTE
174
Figure C-3. Null Modem Cable Configuration
174
Buffering and Handshaking
175
Figure C-4. Minimum Null Modem Cable Configuration
175
Hardware Handshake
176
Xon/Xoff
177
Appendix D Operation of the GPIB
178
Types of Messages
178
Talkers, Listeners, and Controllers
178
The Controller-In-Charge and System Controller
180
GPIB Signals and Lines
180
Data Lines
181
Figure D-1. GPIB Cable Connector
181
Handshake Lines
182
NRFD* (Not Ready for Data
182
NDAC* (Not Data Accepted
182
DAV* (Data Valid
182
Interface Management Lines
182
ATN* (Attention
182
IFC* (Interface Clear
183
REN* (Remote Enable
183
Srq
183
EOI* (End or Identify
183
Physical and Electrical Characteristics
183
Figure D-2. Linear Configuration of the GPIB Devices
184
Figure D-3. Star Configuration of GPIB Devices
185
Related Document
186
Appendix E Common Questions
187
S Mode
187
G Mode
189
Appendix F Parallel Polling
190
Operation
190
Configuration
191
The Parallel Poll
192
Disabling Parallel Poll Response
192
S Mode Example
192
Appendix G Setting Switches
194
Figure G-1. S Mode, 7 Data Bits, 1 Stop Bit, Even Parity, 300 Baud
194
Figure G-2. S Mode, 8 Data Bits, 1 Stop Bit, Even Parity, 19200 Baud
195
Figure G-3. S Mode, 8 Data Bits, 1 Stop Bit, no Parity, 9600 Baud
196
Figure G-4. S Mode, 7 Data Bits, 1 Stop Bit, Even Parity, 300 Baud
196
Figure G-5. S Mode, 8 Data Bits, 1 Stop Bit, Even Parity, 9600 Baud
197
Appendix H Sample Programs
198
S Mode Sample Programs
198
Using an HP 7475A Plotter with a Terminal
199
Getting Ready to Program
199
Figure H-1. S Mode, 8 Data Bits, 1 Stop Bit, no Parity, 19200 Baud
199
Programming Steps
200
Step 1. Stat Function
200
Step 2. Serial Port Functions
200
Step 3. GPIB Initialization Functions
201
Step 4. Communicate with Rd and Wrt Functions
201
Using an HP 7475A Plotter with an IBM PC
202
Getting Ready to Program
202
Figure H-2. S Mode, 7 Data Bits, 1 Stop Bit, no Parity, 9600 Baud
202
Programming Steps
203
Step 1. Stat Function
203
Step 2. Serial Port Functions
203
Step 3. GPIB Initialization Functions
203
Step 4. Communicate with Rd and Wrt Functions
204
Programming a Tektronix 2445 Oscilloscope from an Apple IIC
205
Getting Ready to Program
205
Figure H-3. S Mode, 8 Data Bits, 1 Stop Bit, no Parity, 9600 Baud
205
Programming Steps
206
Step 1. Stat Function
206
Step 2. Serial Port Functions
206
Step 3. GPIB Initialization Functions
206
Step 4. Communicate with Rd and Wrt Functions
206
G Mode Sample Programs
207
Getting Ready to Program
208
Programming Steps
209
Step 1. Stat Function
209
Step 2. GPIB Initialization Functions
209
Step 3. Serial Port Initialization Functions
209
Step 4. Communicate with Plotter
210
IBM PC (with GPIB-PC) to Serial Printer
211
Getting Ready to Program
211
Programming Steps
212
Step 1. Stat Function
212
Step 2. GPIB Initialization Functions
212
Step 3. Serial Port Initialization Functions
212
Step 4. Communicate with the Printer
212
Advertisement
Advertisement
Related Products
National Instruments GPIB-232
National Instruments GPIB-232CT-A IBCL EPROM
National Instruments GPIB-SCSI-A
National Instruments GPIB-VXI/C
National Instruments GPIB Series
National Instruments GPIB-ENET
National Instruments GPIB-ENET Series
National Instruments GPIB PCI-GPIB
National Instruments GPIB-110
National Instruments GPIB-1284CT
National Instruments Categories
Control Unit
I/O Systems
Controller
Computer Hardware
Measuring Instruments
More National Instruments Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL