Sign In
Upload
Manuals
Brands
Feasa Manuals
Test Equipment
10D
Feasa 10D Manuals
Manuals and User Guides for Feasa 10D. We have
1
Feasa 10D manual available for free PDF download: User Manual
Feasa 10D User Manual (66 pages)
Display Analyser
Brand:
Feasa
| Category:
Test Equipment
| Size: 1.16 MB
Table of Contents
Table of Contents
3
Introduction
5
Physical Layout
6
USB Port Control
6
Serial Port Control
7
Capture Commands
8
Capturedark Store Dark Level
9
Capturedark## Store Dark Level
10
Capture Store Display Data
11
Capture# Store Display Data
12
Capturecontrasthigh Store High Contrast Data
13
Capturecontrastlow Store Low Contrast Data
14
Get Data Commands
15
Under Range Condition
15
Over Range Condition
15
Getaverage - Get the Number of Captures to Average
16
Getchannelstatus - Get the Status of Connected Channels
17
Getluminance## - Get the Luminance Value for a Channel
18
Getluminanceall - Get the Luminance of All Fibers
19
Getcontrastratio## - Get the Contrast Ratio for a Channel
20
Getxy## - Return the Xy Chromaticity Values
21
Getxoffset## - Return the X Chromaticity Offset
22
Getyoffset## - Return the y Chromaticity Offset
23
Getuv## - Return the U'V' Chromaticity Values
24
Getwavelength## - Get the Dominant Wavelength
25
Getwavelengthoffset## - Get the Dominant Wavelength Offset
26
Getabsint## Get the Absolute Intensity Value of the Display under Test
27
Getfactor - Get the Exposure Factor
28
Getformat Get the Format of the Data
29
Getcct - Get Correlated Color Temperature
30
Getxxxall Get the Data for ALL Channels on the Analyser
31
Set Commands
32
Setaverage - Set the Number of Captures to Average
33
Setengineeringformat - Set the Data Format to Engineering
34
Setscientificformat - Set the Data Format to Scientific
35
Setfactor## Set the Exposure Factor
36
Setxoffset##0.XXX - Set the X Chromaticity Offset
37
Setyoffset##0.Yyy - Set the y Chromaticity Offset
38
Setwavelengthoffset@@ ## Set the Wavelength Offset
39
User Calibration
40
Setcalibration# Set the Calibrationto a Particular Set
41
Getcalibration Returns the Calibration Set Number
42
Setcalrgbm - Copy the Factory Set to the Current Set
43
Daisy Chain Mode
44
Daisy Chain USB Method
44
Daisy Chain SERIAL Method
45
Busfree - Deactivate any Active Analysers
47
Busget#### - Activate a Display Analyser
48
Busc - Initiate Capture for All Display Analyser's
49
Busc# Initiate Capture for All Display Analyser's
50
Busce#### Poll each Display Analyser to Verify a Capture Is Complete
51
Ports Description and Wiring
52
Daisy Chain Pinout
53
Step-By-Step Method for Daisy Chaining
54
Example
56
General Commands
58
Getserial Get the Serial Number of the Analyser
58
Getversion - Get the Firmware Version
59
Gethw - Get the Hardware Version
60
Getinfo - Get a Summary of the Display Analyser Details
61
Setbaud- Change the Baud Rate
62
HELP - Command Summary Listing
63
Command Summary
64
Back to Index
65
Warranty
66
Advertisement
Advertisement
Related Products
Feasa 10-F
Feasa 10-FB
Feasa 10-LT
Feasa 10-IR
Feasa 10-IRP
Feasa 3D
Feasa 6D
Feasa Categories
Measuring Instruments
Test Equipment
More Feasa Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL