Endress+Hauser Proline Prosonic Flow 91W Technical Information (44 pages)
Ultrasonic Flow Measuring System; Flowrate measurement for standard applications with drinking water, wastewater and process water
Brand:
Endress+Hauser
| Category:
Measuring Instruments
| Size: 1.54 MB
Table of Contents
Technical Information
1
Table of Contents
2
Function and System Design
3
Measuring Principle
3
System Design Measuring System
3
System Design Clamp-On Sensors
4
System Design Insertion Sensors
8
System Design Inline Sensors
9
Measuring System
10
Input
12
Measured Variable
12
Measuring Range
12
Operable Flow Range
12
Input Signal
12
Output
12
Output Signal
12
Signal on Alarm
14
Load
14
Switching Output
14
Low Flow Cut off
14
Galvanic Isolation
14
Power Supply
15
Electrical Connection Measuring Unit for
15
Prosonic Flow 90/93 (Standard Version)
15
Electrical Connection Measuring Unit Prosonic Flow
17
(Standard Version)
17
Electrical Connection Measuring Unit for Prosonic Flow
18
(Profibus Pa)
18
Electrical Connection Measuring Unit for Prosonic Flow
19
(Profibus Pa)
19
Electrical Connection Measuring Unit for Prosonic Flow
20
(FOUNDATION Fieldbus)
20
Electrical Connection Sensor Connecting Cable Prosonic Flow 90/93
21
Electrical Connection Sensor Connecting Cable
22
Prosonic Flow 91
22
Supply Voltage (Power Supply)
22
Cable Entry
22
Cable Specifications
23
Power Consumption
23
Power Supply Failure
23
Potential Equalization
23
Performance Characteristics
24
Reference Operating Conditions
24
Maximum Measured Error
24
Repeatability
25
Operating Conditions: Installation
26
Installation Instructions
26
Inlet and Outlet Run
30
Length of Connecting Cable
30
Operating Conditions: Environment
31
Ambient Temperature Range
31
Storage Temperature
31
Degree of Protection
31
Shock and Vibration Resistance
31
Electromagnetic Compatibility (EMC)
31
Operating Conditions: Process
32
Medium Temperature Range
32
Medium Pressure Range (Nominal Pressure)
32
Pressure Loss
32
Mechanical Construction
33
Design, Dimensions
33
Weight
39
Material
40
Human Interface
41
Display Elements
41
Operating Elements
41
Remote Operation
41
Language Group
41
Certificates and Approvals
42
CE Mark
42
C-Tick Mark
42
Ex Approval
42
PROFIBUS PA Certification
42
FOUNDATION Fieldbus Certification
42
Other Standards and Guidelines
42
Ordering Information
42
Accessories
43
Documentation
43
Registered Trademarks
43
Advertisement
Endress+Hauser Proline Prosonic Flow 91W Technical Information (24 pages)
Ultrasonic Flow Measuring System. Flowrate measurement for standard applications with drinking water and process water.
Brand:
Endress+Hauser
| Category:
Measuring Instruments
| Size: 0.78 MB
Table of Contents
Table of Contents
2
Function and System Design
3
Measuring Principle
3
Measuring
4
Sensor Selection and Arrangement
5
Input
6
Measured Variable
6
Measuring Range
6
Operable Flow Range
6
Output
6
Output Signal
6
Signal on Alarm
6
Load
6
Low Flow Cutoff
6
Galvanic Isolation
6
Power Supply
7
Measuring Unit Electrical Connection
7
Connecting the Connecting Cable
8
Supply Voltage
8
Cable Entry
8
Cable-Specification
9
Power Consumption
9
Power Supply Failure
9
Potential Equalization
9
Performance Characteristics
10
Reference Operating Conditions
10
Maximum Measured Error
10
Repeatability
10
Operating Conditions: Installation
11
Installation Instructions
11
Inlet and Outlet Runs
12
Connection Cable
12
Operating Conditions: Environment
12
Ambient Temperature Range
12
Storage Temperature
12
Degree of Protection
13
Shock and Vibration Resistance
13
Operating Conditions: Process
13
Medium Temperature Range
13
Medium Pressure Range (Nominal Pressure)
13
Pressure Loss
13
Energy Measurement
13
Mechanical Construction
14
Design, Dimensions
14
Weight
18
Materials
18
Human Interface
18
Display Elements
18
Operating Elements
18
Remote Operation
18
Language Group
18
Certificates and Approvals
19
CE Mark
19
C-Tick Mark
19
Ex Approval
19
Other Standards and Guidelines
19
Ordering Information
19
Accessories
20
Device-Specific Accessories
20
Communication-Specific Accessories
21
Service-Specific Accessories
22
Documentation
23
Registered Trademarks
23
Endress+Hauser Proline Prosonic Flow 91W Brief Operating Instructions (36 pages)
Ultrasonic flow measuring system
Brand:
Endress+Hauser
| Category:
Measuring Instruments
| Size: 0.99 MB
Table of Contents
Table of Contents
2
1 Safety Instructions
3
Designated Use
3
Installation, Commissioning and Operation
3
Operational Safety
3
Safety Conventions
4
2 Installation
5
Installation Conditions
5
Preparatory Steps Prior to Installation
7
Determining the Necessary Installation Distances
8
Mounting the Transmitter
8
Connecting the Power Supply
9
Mechanical Preparation
9
Installing Prosonic Flow W Sensor
14
Post-Installation Check
21
3 Hardware and Software Settings
21
4 Wiring
22
Sensor/Transmitter Connecting Cable
23
Connecting the Transmitter
27
Protective Ground Connection
28
Degree of Protection
29
Post-Connection Check
29
5 Commissioning
30
Switching on the Measuring Device
30
Operation
31
Navigating Within the Function Matrix
32
Group Sensor Setup
33
Troubleshooting
33
Advertisement
Advertisement
Related Products
Endress+Hauser Proline Prosonic Flow 93T Portable
Endress+Hauser Proline Prosonic Flow 90U
Endress+Hauser Proline Prosonic Flow 90W
Endress+Hauser Proline Prosonic Flow 93C
Endress+Hauser Proline Prosonic Flow 93U
Endress+Hauser Proline Prosonic Flow 93W
Endress+Hauser Proline Prosonic Flow 92F
Endress+Hauser 9P5B
Endress+Hauser Proline Prosonic Flow 93P
Endress+Hauser Proline Prosonic Flow P
Endress+Hauser Categories
Measuring Instruments
Transmitter
Radar
Switch
Accessories
More Endress+Hauser Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL