Sign In
Upload
Manuals
Brands
Emerson Manuals
Air Conditioner
Copeland EazyCool ZXDE050E
Emerson Copeland EazyCool ZXDE050E Manuals
Manuals and User Guides for Emerson Copeland EazyCool ZXDE050E. We have
2
Emerson Copeland EazyCool ZXDE050E manuals available for free PDF download: Application Manuallines
Emerson Copeland EazyCool ZXDE050E Application Manuallines (71 pages)
Outdoor Condensing Unit
Brand:
Emerson
| Category:
Heat Pump
| Size: 2.67 MB
Table of Contents
Appendix 8: List of Tables and Figures
8
Table 1: Qualified Refrigerants and Oils
8
Figure 1: Nomenclature ZX Units
8
Table 2: BOM History
9
Table 3: Compressor Models Cross Reference
9
Figure 2: ZX Unit Housing
10
Table 4: Condenser Fans Technical Data
10
Figure 3: P&I Diagram for ZXME Units
11
Table 5: Legend of the P&I Diagram for ZXME Units
11
Figure 4: P&I Diagram for ZXLE Units
12
Table 6: Legend of the P&I Diagram for ZXLE Units
12
Figure 5: P&I Diagram for ZXDE Units
13
Table 7: Legend of the P&I Diagram for ZXDE Units
13
Figure 6: Electronic Controller
14
Figure 7: XCM25D Controller Functionality Overview
15
Table 8: Prearranged Additional Connections
16
Figure 8: Prearranged Additional Connections
16
Table 9: Room Thermostat External Parameters
17
Figure 9: External Temperature Sensor - Functionality
17
Table 10: External Temperature Sensor - Parameters
18
Table 11: Defrost Parameters
19
Figure 10: Local Display
20
Table 12: LED Functions Description
21
Table 13: Display Visualisation
21
Table 14: Single Commands
21
Table 15: Double Commands
21
Table 16: Programming Level 1 Parameters
22
Table 17: Fast Access Menu
23
Table 18: Parameters in Pr1
23
Table 19: Minimum Cut-Out Value for Pumpdown
24
Table 20: Pumpdown 1
24
Figure 11: Pumpdown Functionality with Temperature Sensor
25
Table 21: Pumpdown 2
25
Table 22: Pumpdown 3
26
Figure 12: Emerson "Hot Key
27
Figure 13: Location of "Hot Key" Plug Connection
27
Table 23: How to Check the Alarm List
28
Figure 14: Dimensions of Models ZXME020E, ZXME025E, ZXME030E & ZXME040E and Models ZXLE020E, ZXLE030E & ZXLE040E (Single-Fan Units)
30
Figure 15: Dimensions of Models ZXME050E, ZXME060E, ZXME075E, ZXDE040E, ZXDE050E, ZXDE060E, ZXDE075E, ZXLE050E, ZXLE060E & ZXLE075E (Dual-Fan Units)
30
Figure 16: Transport and Storage
31
Table 24: Weights
31
Table 25: Maximum Operating Currents for Cable Selection
32
Table 26: Maximum Distance between 2 Clamp Supports
33
Figure 17: Brazing - Sectional View
34
Figure 18: Suction Tube Brazing Areas
34
Figure 19: Fixing Dimensions and Distances - Single-Fan Unit
35
Figure 20: Fixing Dimensions and Distances - Dual-Fan Unit
36
Figure 21: Service Valves for Refrigerant Charging
37
Figure 22: Liquid Line Service Port
38
Table 27: Overview of the ZX Unit Components
41
Figure 23: Wiring Diagram
43
Table 28: Parameters Level 1
43
Table 29: Parameter List Level 1 (Pr1) & 2 (Pr2)
59
Table 30: Alarm Code Overview
63
Table 31: Additional Features for Customization
67
Table 32: B7 AI7 Optional Sensor >> Resistance / Temperature Curve
68
Advertisement
Emerson Copeland EazyCool ZXDE050E Application Manuallines (80 pages)
Outdoor Condensing Units
Brand:
Emerson
| Category:
Air Conditioner
| Size: 5.22 MB
Table of Contents
Figure 1: Nomenclature ZX Units
8
Figure 2: ZX Unit Housing
11
Figure 3: P&I Diagram for ZXME Units
12
Figure 4: P&I Diagram for ZXLE Units
13
Figure 5: P&I Diagram for ZXDE Units
14
Figure 6: Electronic Controller
15
Figure 7: XCM25D Controller Functionality Overview
16
Figure 8: Prearranged Additional Connections
18
Figure 9: External Temperature Sensor - Functionality
19
Figure 10: Local Display
23
Figure 11: Remote Display Front Panel Mounting
24
Figure 12: VNR Connection for the Remote Display
24
Figure 13: Digital Operation
28
Figure 14: Pump-Down Functionality with Temperature Sensor
30
Figure 15: Emerson "Hot Key
31
Figure 16: Location of "Hot Key" Plug Connection
31
Figure 17: Dimensions of Models ZXME020E to ZXME040E, ZXDE030E and ZXLE020E to ZXLE040E (Single-Fan Units)
34
Figure 18: Dimensions of Models ZXME050E to ZXME075E, ZXDE040E to ZXDE075E and ZXLE050E to ZXLE075E (Dual-Fan Units)
34
Figure 19: Transport and Storage
35
Figure 20: Replacement of the Fuses
37
Figure 21: Brazing - Sectional View
39
Figure 22: Suction Tube Brazing Areas
39
Figure 23: Fixing Dimensions and Distances - Single-Fan Unit
40
Figure 24: Fixing Dimensions and Distances - Dual-Fan Unit
40
Figure 25: Service Valves for Refrigerant Charging
42
Figure 26: Liquid Line Service Port
42
Figure 27: Wiring Diagram - 3-Phase Motor
47
Figure 28: Wiring Diagram - 1-Phase Motor
48
Advertisement
Related Products
Emerson Copeland EazyCool ZXDE030E
Emerson Copeland EazyCool ZXDE040E
Emerson Copeland EazyCool ZXDE075E
Emerson Copeland EazyCool ZXDE060E
Emerson ZXD Series
Emerson Copeland EazyCool ZXLE075E
Emerson Copeland ZXME-013E
Emerson Copeland ZXLE-028E
Emerson Copeland ZXLE-018E
Emerson ZX0750-TF5
Emerson Categories
Controller
Control Unit
Transmitter
Measuring Instruments
Fan
More Emerson Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL