Sign In
Upload
Manuals
Brands
Daikin Manuals
Air Conditioner
RXA50A2V1B
Daikin RXA50A2V1B Manuals
Manuals and User Guides for Daikin RXA50A2V1B. We have
2
Daikin RXA50A2V1B manuals available for free PDF download: Service Manual, Installation Manual
Daikin RXA50A2V1B Service Manual (76 pages)
Split Stylish R32
Brand:
Daikin
| Category:
Air Conditioner
| Size: 30.5 MB
Table of Contents
Table of Contents
3
A5-00 - Freeze-Up Protection / Heating Peak Cut Control
5
A6-00 - Indoor Unit Fan Motor Abnormality
5
AH-00 - Streamer Unit Abnormality
5
C4-00 - Indoor Heat Exchanger Thermistor
5
C9-00 - Room Thermistor Abnormality
5
E1-00 - PCB Defect
6
E3-00 - High Pressure Switch Abnormality
6
Humidity Sensor Abnormality
6
Intelligent Thermal Sensor Abnormality
6
E5-00 - Overheat of Inverter Compressor Motor
7
E6-00 - Compressor Startup Defect
7
Cooling/Heating Switch Abnormality
8
E7-00 - Fan Lock Abnormality
8
E8-00 - Input Overvoltage Abnormality
8
F3-00 - Discharge Pipe Temperature Stop
8
Abnormality
8
F6-00 - Stop Due to Cooling High Pressure
9
F8-00 - System Shutdown Due to Compressor Internal Temperature Abnormality
9
H0-00 - Current Sensor Abnormality
9
H0-00 - Current Sensor Abnormality
10
H3-00 - High Pressure Switch Defect
10
H6-00 - Location Detection Sensor Abnormality
10
H8-00 - Compressor Input Abnormality
10
H9-00 - Outdoor Air Thermistor Abnormality
11
J3-00 - Discharge Pipe Thermistor Dislocation Abnormality
11
J6-00 - Outdoor Heat Exchanger Thermistor Abnormality
11
L3-00 - Electrical Component Temperature Abnormality
11
L4-00 - Fin Temperature Increase Abnormality
11
L5-00 - Output over Current Abnormality
12
P4-00 - Fin Thermistor Abnormality
12
U0-00 - Shortage of Refrigerant
12
Indoor/Outdoor Combination Abnormality
13
U2-00 - Main Circuit Voltage Abnormality
13
U4-00 - Indoor/Outdoor Transmission Abnormality
13
U5-00 - Transmission Malfunction between Indoor Unit and Remote Controller
13
Symptom Based Troubleshooting
15
Operation Does Not Start
15
Operation Sometimes Stops
15
Operation Starts but the Unit Does Not Cool/Heat
15
Operating Noise and Vibrations
15
Abnormal High Pressure
16
Abnormal Low Pressure
16
Indoor Fan Starts Operating but the Compressor Does
17
Not Operate
17
Operation Starts and the Unit Stops Immediately
17
Operation Stops, Unit Cannot Start for a While
17
Unit Discharges White Mist
17
Swing Flap Does Not Operate
17
2 Components
18
4-Way Valve
18
Checking Procedures
18
(C)(F)Txa15~50A2V1B(W)(S)(T) + Rxa42+50A2V1B
18
Repair Procedures
19
Compressor
20
Checking Procedures
20
Repair Procedures
22
Expansion Valve
23
Checking Procedures
23
Repair Procedures
24
Front Panel Motor
26
Checking Procedures
26
Repair Procedures
26
High Pressure Switch
27
Checking Procedures
27
Repair Procedures
27
Humidity Sensor
28
Checking Procedures
28
Repair Procedures
28
Indoor Unit Fan Motor
29
Checking Procedures
29
Repair Procedures
29
Indoor Unit PCB
30
Checking Procedures
30
Repair Procedures
31
Intelligent Thermal Sensor
33
Checking Procedures
33
Repair Procedures
33
Inverter PCB
34
Checking Procedures
34
Repair Procedures
35
Main PCB
35
Checking Procedures
35
Repair Procedures
36
Outdoor Unit Fan Motor
38
Checking Procedures
38
Repair Procedures
39
Plate Work
40
Outdoor Unit
40
Indoor Unit
42
Reactor
44
Checking Procedures
44
Repair Procedures
45
Streamer Unit
45
Checking Procedures
45
Swing Flap Motor
46
Main Swing Flap Motor
46
Secondary Swing Flap Motor
47
Swing Raster Motor
48
Checking Procedures
48
Repair Procedures
49
Thermistors
49
Refrigerant Thermistors
49
Other Thermistors
51
Wifi Control PCB
51
Checking Procedures
51
Repair Procedures
51
3 Third Party Components
52
Power Supply
52
Checking Procedures
52
Repair Procedures
52
Refrigerant Circuit
53
Checking Procedures
53
Repair Procedures
54
External Factors
55
Checking Procedures
55
Repair Procedures
55
4 Maintenance
56
To Clean the Outdoor Unit Heat Exchanger
56
To Clean the Indoor Unit Heat Exchanger
56
To Clean the Air Filters
56
5 Technical Data
57
Detailed Information Setting Mode
57
Detailed Information Setting Mode: Indoor Unit
57
Detailed Information Setting Mode: Outdoor Unit
57
Detailed Information Setting Mode: Remote Controller
57
Wiring Diagram
58
Wiring Diagram: Indoor Unit
58
Wiring Diagram: Outdoor Unit
59
Piping Diagram
61
Piping Diagram: Indoor Unit
61
Piping Diagram: Outdoor Unit
62
Component Overview
64
Component Overview: Indoor Unit
64
Component Overview: Outdoor Unit
66
Field Information Report
68
Field Settings
71
To Control Heating Only Mode
71
To Adjust Target Set Temperature in Heating Operation
71
To Control the Indoor Unit Fan During Thermostat off
71
To Change Auto Restart on to off
71
To Control Cooling Mode Only
71
Service Tools
72
Advertisement
Daikin RXA50A2V1B Installation Manual (16 pages)
R32 split series
Brand:
Daikin
| Category:
Air Conditioner
| Size: 1.65 MB
Table of Contents
Installation Manual
1
1 About the Documentation
4
2 About the Box
4
Table of Contents
4
Outdoor Unit
4
To Remove the Accessories from the Outdoor Unit
4
About this Document
4
3 Preparation
5
Preparing the Installation Site
5
Installation Site Requirements of the Outdoor Unit
5
Additional Installation Site Requirements of the Outdoor Unit in Cold Climates
5
Preparing Refrigerant Piping
6
Refrigerant Piping Requirements
6
Refrigerant Piping Length and Height Difference
6
Refrigerant Piping Insulation
6
4 Installation
6
Mounting the Outdoor Unit
6
To Provide the Installation Structure
6
To Install the Outdoor Unit
7
To Provide Drainage
7
To Prevent the Outdoor Unit from Falling over
7
Connecting the Refrigerant Piping
7
Guidelines When Connecting the Refrigerant Piping
7
Using the Stop Valve and Service Port
7
To Connect the Refrigerant Piping to the Outdoor Unit
8
Checking the Refrigerant Piping
8
To Check for Leaks
8
To Perform Vacuum Drying
8
Charging Refrigerant
8
About Charging Refrigerant
8
About the Refrigerant
9
To Determine the Additional Refrigerant Amount
9
To Determine the Complete Recharge Amount
9
To Charge Additional Refrigerant
9
To Fix the Fluorinated Greenhouse Gases Label
9
Connecting the Electrical Wiring
10
Guidelines When Connecting the Electrical Wiring
10
Specifications of Standard Wiring Components
10
To Connect the Electrical Wiring on the Outdoor Unit
10
Finishing the Outdoor Unit Installation
10
To Finish the Outdoor Unit Installation
10
About the Compressor
11
5 Commissioning
11
Checklist before Commissioning
11
Checklist During Commissioning
11
To Perform a Test Run
11
6 Configuration
11
To Set the Facility Mode
11
7 Troubleshooting
12
Fault Diagnosis Using LED on Outdoor Unit PCB
12
8 Disposal
12
To Pump down
12
To Start and Stop Forced Cooling
12
To Start/Stop Forced Cooling Using the Indoor Unit ON/OFF Switch
12
To Start/Stop Forced Cooling Using the Indoor Unit User Interface
12
9 Technical Data
14
Wiring Diagram
14
Piping Diagram
15
Piping Diagram: Outdoor Unit
15
Advertisement
Related Products
Daikin RXA50B2V1B
Daikin RXA50A
Daikin RXA50B
Daikin RXA20A2V1B
Daikin RXA25A
Daikin RXA20A9
Daikin RXA25A9
Daikin RXA25A5V1B9
Daikin RXA20A5V1B8
Daikin RXA35A5V1B8
Daikin Categories
Air Conditioner
Heat Pump
Remote Control
Chiller
Fan
More Daikin Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL