Sign In
Upload
Manuals
Brands
Carrier Manuals
Air Conditioner
50HC07
Carrier 50HC07 Manuals
Manuals and User Guides for Carrier 50HC07. We have
1
Carrier 50HC07 manual available for free PDF download: Service And Maintenance Instructions
Carrier 50HC07 Service And Maintenance Instructions (125 pages)
Single Package Rooftop Electric Cooling Unit with Puron R-410A Refrigerant 3 to 12.5 Nominal Tons Sizes 04-14
Brand:
Carrier
| Category:
Air Conditioner
| Size: 13.08 MB
Table of Contents
Table of Contents
1
Safety Considerations
1
Unit Arrangement and Access
2
Seasonal Maintenance
3
Air Conditioning
3
Economizer or Outside Air Damper
3
Routine Maintenance
3
Supply Fan (Direct- -Drive)
4
ECM Motor
4
Evaluating Motor Speed
4
Supply Fan (Blower) Section
4
Motor “Rocking” on Start-Up
5
Troubleshooting the ECM Motor
5
Supply Fan (Belt-Drive)
5
Motor Test Volts
5
Checking Blower Motor Belt Tension
6
Replacing the Belt
6
Typical Belt Drive Motor Mounting
6
Belt
6
Unit Installation with SAV Option
7
Staged Air Volume Control - - 2 Speed Fan with Variable Frequency Drive (Vfd)
7
Changing the Fan Speed
7
Identifying Factory Option
7
Aligning Blower and Motor Pulleys
7
With Variable Frequency Drive (Vfd)
7
Replacing the Motor
8
Replacing Belt Driven Motor
8
Additional Variable Frequency Drive (Vfd) Installation and Troubleshooting
8
Motor
8
Changing Fan Wheel Speed
9
Remote VFD Keypad Reference
10
SRT Unit VFD Parameters
11
Condenser Coil
12
Condenser Coil Maintenance and Cleaning Recommendation
12
Remove Surface Loaded Fibers
12
Cooling
12
Cleaning the Evaporator Coil
13
Totaline Environmentally Sound Coil Cleaner Application Equipment
13
Totaline Environmentally Sound Coil Cleaner Application Instructions
13
Evaporator Coil
13
Replacing TXV
14
Refrigerant System Pressure Access Ports
14
TXV Valve and Sensing Bulb Location
14
Thermostatic Expansion Valve (Txv)
14
Puronr (R- - 410A) Refrigerant
15
Refrigerant Charge
15
No Charge
15
Low-Charge Cooling
15
Coremax Access Port Assembly
16
Seat
16
Core
16
Cooling Charging Charts
17
Replacing Compressor
21
Compressor Rotation
21
Lubrication
21
Compressor
21
Filter Drier
22
Condenser-Fan Adjustment
22
Troubleshooting Cooling System
22
Cooling Troubleshooting
23
Convenience Outlet Location
24
Weatherproof Cover Installation
24
Convenience Outlets
24
Controller Assembly
25
Powered Convenience Outlet Wiring
25
Smoke Detectors
25
Smoke Detector Sensor
26
Smoke Detector Locations
26
Supply Air
26
Typical Supply Air Smoke Detector Sensor Location
26
Completing Installation of Return Air Smoke Detector
27
Return Air Smoke Detector Sensor with Economizer
27
Return Air Sensor Operating Position
27
FIOP Smoke Detector Wiring and Response
28
Typical Smoke Detector System Wiring
28
Dirty Controller Test
29
Controller Alarm Test
29
Controller Alarm Test Procedure
29
Sensor Alarm Test
29
Sensor and Controller Tests
29
Changing the Dirt Sensor Test
30
Remote Test/Reset Station Dirty Sensor Test
30
Remote Station Test
30
Dirty Sensor Test Procedure
30
Detector Cleaning
31
Alarm State
31
Indicators
31
Normal State
31
Controller’s Trouble LED Is Flashing
32
Sensor’s Trouble LED Is on
32
Controller’s Trouble LED Is on
32
Protective Devices
32
Relief Device
33
Detector Indicators
33
Premierlink Control
33
Rtu- -Open Control System
33
Sensory/Accessory Installation
34
Additional Rtu- -Open Installation and Troubleshooting
34
RTU-Open Control Module
35
Economizer Systems
36
Outdoor Air Temperature (OAT) Sensor
38
Supply Air Temperature (SAT) Sensor
38
Outdoor Air Lockout Sensor
38
Differential Dry Bulb Control
39
Outdoor Dry Bulb Changeover
39
Outdoor Enthalpy Changeover
40
Differential Enthalpy Control
40
Enthalpy Changeover Setpoints
40
Damper Movement
41
Minimum Position Control
41
Indoor Air Quality (IAQ) Sensor Input
41
Exhaust Setpoint Adjustment
41
Thermostats
42
Occupancy Control
42
Demand Control Ventilation (DCV)
42
CO2 Sensor Configuration
42
DCV (Demand Controlled Ventilation) and Power Exhaust
43
To Check DCV and Power Exhaust
43
Single Enthalpy
43
Differential Enthalpy
43
Air Sensor Input
44
Pre- -Start- -Up/Start- -Up
44
Unit Preparation
45
Additional Installation/Inspection
45
Compressor Mounting
45
Start- -Up, General
45
Start- -Up, Premierlink Controls
46
Start- -Up, Rtu- -Open Controls
46
Fastener Torque Values
47
Model Number Nomenclature
48
Appendix I. Model Number Significance 48.
49
Appendix II. Physical Data
49
Appendix III. Fan Performance
52
Speed/Torque Motor
67
Appendix IV Wiring Diagrams
71
50HC*A05/06 Outdoor Circuiting
121
50HC*A07 Outdoor Circuiting
121
50HC*A04 Outdoor Circuiting
121
Appendix V. Motormaster Sensor Locations
121
50HC*A09 Outdoor Circuiting
122
50HC*D14 Outdoor Circuiting
122
50HC*D08 Motormaster Sensor Location - Novation Coils (MCHX)
123
50HC*D12 Motormaster Sensor Location - Novation Coils (MCHX)
123
Preliminary Information
124
Pre-Start-Up
124
Unit Start-Up Checklist
124
Advertisement
Advertisement
Related Products
Carrier /50HC 04-28
Carrier WeatherMaster 50HC04
Carrier WeatherMaster 50HC05
Carrier WeatherMaster 50HC06
Carrier 50HC08
Carrier 50HC09
Carrier WeatherMaster 50HC*D11 Series
Carrier WeatherMaster 50HCQ 05 Series
Carrier WeatherMaster 50HC*D07 Series
Carrier WeatherMaster 50HC*E11 Series
Carrier Categories
Air Conditioner
Heat Pump
Furnace
Thermostat
Chiller
More Carrier Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL