Honeywell TH8320U Installation Instructions Manual page 17

Touch screen programmable thermostats
Hide thumbs Also See for TH8320U:
Table of Contents

Advertisement

Installer
Setup
Select
Number
Keypad
0670
Lockout
Temperature
0680
Control in Heat
Temperature
0690
Control in Cool
Temperature
0700
Display Offset
Reset
0710
Thermostat
TH8320U AND TH8321U TOUCH SCREEN PROGRAMMABLE THERMOSTATS
Table 6. Advanced Settings Menu. (Continued)
Factory Setting
Option
Description
0
Unlocked keypad
2
Standard
temperature control
in heating
2
Standard
temperature control
in cooling
0
No difference in
displayed
temperature and
actual room
temperature
0
No thermostat reset. 1
Other Choices
Options
Description
1, 2
1—partially locked
keypad
2—fully locked
keypad
1, 3
1—less aggressive
temperature
control (could
cause temperature
undershoot)
3—more
aggressive
temperature
control (could
cause temperature
overshoot)
1, 3
1—less aggressive
temperature
control (could
cause temperature
undershoot)
3—more
aggressive
temperature
control (could
cause temperature
overshoot)
-3, -2, -1,
°
-3
F (-1.5
0, 1, 2, 3
-2°F (-1°C)
-1°F (-.5°C)
0 F (0.°C)
1°F (.5°C)
2°F (1°C)
3°F (1.5°C)
Resets all Installer
Setup Options to
default values and
resets schedule to
default setting.
17
Comments
Unlocked—all
functions are
available.
Partially locked—
only temperature up
and down keys and
ability to enter and
modify Installer
Setup mode are
available.
Fully locked—only
ability to enter and
modify Installer
Setup mode are
available.
Applies to recovery
ramp and use of
auxiliary heat during
recovery.
Choose 1 if getting
temperature
overshoot.
Choose 3 if getting
temperature
undershoot.
Applies to recovery
ramp.
Choose 1 if getting
temperature
overshoot.
Choose 3 if getting
temperature
undershoot.
°
C)
Only calendar
settings and time are
retained.
69-1706

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Th8321u

Table of Contents