8.5 Network

If an additional interface is available on the heat pump manager,
the settings in the "network" menu must be adjusted.




8.5.1
Determining the IP address
When using the NWPM expansion, there is the option of reading
out a dynamic IP address allocated by the router or setting a
fixed IP address.
The menu is accessed by:
Simultaneously pressing (approx. 5 seconds) the key
combination (ESC) and (ENTER).












EN-16
Adjusting the interface for remote diagnostics
The protocol setting is used to specify the type of the installed
interface and the transfer protocol.
When using Modbus, an address must be assigned to the device
attached to the network. This address is used for communicating
with the device.
When using Modbus, the baud rate must be adjusted to the system
baud rate. Ensure that the same baud rate is set on both sides of
the communication system.
Adjusting the interface for remote diagnostics
Select OTHER INFORMATION with the arrow keys are confirm
with ENTER
Select PCOWEB/NET CONFIG with the arrow keys and confirm
with ENTER
Select PCOWEB settings with the arrow keys and confirm with
ENTER
Is DHCP active?
Read out/set the IP address
Read out/set the subnet mask
Read out/set the gateway address
Read out/set the DNS1 address
Read out/set the DNS2 address
Has a change been made? If so, YES must be selected and
confirmed with ENTER. The heat pump manager must restart after
a change has been made. Only then will the amended setting be
applied.
452114.66.71 FD 9305
the additional submenus are accessed by pressing the
(ENTER) key
a mask change in the submenu is achieved via the arrow
keys
To return to the standard display, briefly press the (MENUE)
key
L14<
Setting range
--
LAN
Modbus
EIB / KNX
Modbus Extended
000 ... 001 ... 199
1200
2400
4800
9600
19200
Setting range
ON / OFF
000 ... 255
000 ... 255
000 ... 255
000 ... 255
000 ... 255
NO / YES