Electrical Adjustments
No.
Adjustment Item
2
FAN_TEMP_C_WARNING
3
FAN_TEMP_B-A_WARNING
4
FAN_TEMP_C-A_WARNING
5
FAN_CONTROL_SW
6
FAN_1_SPEED_CTRL
7
FAN_2_SPEED_CTRL
8
9
FAN_1_SPEED_MONI
10
FAN_2_SPEED_MONI
11
12
FAN_TEMP_A_MONI
13
FAN_TEMP_B_MONI
14
FAN_TEMP_C_MONI
15
16
TEMP_UPWARNING_TIME
17
NOR_TEMP_FAN1_MIN
18
NOR_TEMP_FAN1_MAX
19
NOR_TEMP_FAN2_MIN
20
NOR_TEMP_FAN2_MAX
21
22
23
NOR_VALU_FAN1_MIN
24
NOR_VALU_FAN1_MAX
25
NOR_VALU_FAN2_MIN
26
NOR_VALU_FAN2_MAX
27
28
29
ECO_TEMP_FAN1_MIN
30
ECO_TEMP_FAN1_MAX
31
ECOTEMP_FAN2_MIN
32
ECO_TEMP_FAN2_MAX
33
34
35
ECO_VALU_FAN1_MIN
36
ECO_VALU_FAN1_MAX
37
ECO_VALU_FAN2_MIN
38
ECO_VALU_FAN2_MAX
39
40
41
HINOR_TEMP_FAN1_MIN
42
HINOR_TEMP_FAN1_MAX
43
HINOR_TEMP_FAN2_MIN
44
HINOR_TEMP_FAN2_MAX
45
46
47
HINOR_VALU_FAN1_MIN
48
HINOR_VALU_FAN1_MAX
49
HINOR_VALU_FAN2_MIN
50
HINOR_VALU_FAN2_MAX
51
52
53
HIECO_TEMP_FAN1_MIN
54
HIECO_TEMP_FAN1_MAX
55
HIECOTEMP_FAN2_MIN
56
HIECO_TEMP_FAN2_MAX
57
58
59
HIECO_VALU_FAN1_MIN
60
HIECO_VALU_FAN1_MAX
61
HIECO_VALU_FAN2_MIN
62
HIECO_VALU_FAN2_MAX
63
64
65
CLNOR_TEMP_FAN1_MIN
66
ClNOR_TEMP_FAN1_MAX
67
CLNOR_TEMP_FAN2_MIN
68
CLNOR_TEMP_FAN2_MAX
69
70
71
CLNOR_VALU_FAN1_MIN
72
CLNOR_VALU_FAN1_MAX
73
CLNOR_VALU_FAN2_MIN
74
CLNOR_VALU_FAN2_MAX
75
76
77
CLECO_TEMP_FAN1_MIN
78
CLECO_TEMP_FAN1_MAX
79
CLECOTEMP_FAN2_MIN
80
CLECO_TEMP_FAN2_MAX
81
82
83
CLECO_VALU_FAN1_MIN
84
CLECO_VALU_FAN1_MAX
85
CLECO_VALU_FAN2_MIN
Initial Value
Range
Input source / Description
73
30 ~ 100
Temperature C to judge the abnormal temperature, for Lamp
100
0 ~ 100
Temperature B-A to judge the abnormal temperature, for detecting clogged filter
100
0 ~ 100
Temperature C-A to judge the abnormal temperature, for detecting clogged filter
0
0 or 1
0: Auto Fan Control 1:Manual Control
135
0 ~ 255
Manual Adjustment Mode when FAN_CONTROL_SW=1
135
0 ~ 255
-
0 ~ 255
Fan Speed Monitor when FAN_CONTROL_SW=0, Read Only
-
0 ~ 255
-
-
Read Only
-
-
-
-
3
0 ~ 5
+15 degrees is added to Abnormal Temperature Value during x min after power on.
46
Control Start Temperature for FAN1 at Normal Mode
52
Control End Temperature for FAN1 at Normal Mode
46
0~255
Control Start Temperature for FAN2 at Normal Mode
52
Control End Temperature for FAN2 at Normal Mode
70
Minimum Control Value for FAN1 at Normal Mode (0: Fan Voltage 0V, 255: Fan Voltage 25.5V)
135
Maximum Control Value for FAN1 at Normal Mode
95
0~255
Minimum Control Value for FAN2 at Normal Mode
125
Maximum Control Value for FAN2 at Normal Mode
46
Control Start Temperature for FAN1 at Eco Mode
52
Control End Temperature for for FAN1 at Eco Mode
46
0~255
Control Start Temperature for FAN2 at Eco Mode
52
Control End Temperature for for FAN2 at Eco Mode
60
Minimum Control Value for FAN1 at Eco Mode
120
Maximum Control Value for FAN1 at Eco Mode
74
0~255
Minimum Control Value for FAN2 at Eco Mode
100
Maximum Control Value for FAN2 at Eco Mode
45
Control Start Temperature for FAN1 at Highland Normal Mode
50
Control End Temperature for FAN1 at Highland Normal Mode
45
0~255
Control Start Temperature for FAN2 at Highland Normal Mode
50
Control End Temperature for FAN2 at Highland Normal Mode
75
Minimum Control Value for FAN1 at Highland Normal Mode (0: Fan Voltage 0V, 255: Fan Voltage 25.5V)
135
Maximum Control Value for FAN1 at Highland Normal Mode
100
0~255
Minimum Control Value for FAN2 at Highland Normal Mode
130
Maximum Control Value for FAN2 at Highland Normal Mode
45
Control Start Temperature for FAN1 at Highland Eco Mode
50
Control End Temperature for FAN1 at Highland Eco Mode
45
0~255
Control Start Temperature for FAN2 at Highland Eco Mode
50
Control End Temperature for FAN2 at Highland Eco Mode
65
Minimum Control Value for FAN1 at Highland Eco Mode (0: Fan Voltage 0V, 255: Fan Voltage 25.5V)
125
Maximum Control Value for FAN1 at Highland Eco Mode
80
0~255
Minimum Control Value for FAN2 at Highland Eco Mode
110
Maximum Control Value for FAN2 at Highland Eco Mode
46
Control Start Temperature for FAN1 at Ceiling Normal Mode
52
Control End Temperature for FAN1 at Ceiling Normal Mode
46
0~255
Control Start Temperature for FAN2 at Ceiling Normal Mode
52
Control End Temperature for FAN2 at Ceiling Normal Mode
70
Minimum Control Value for FAN1 at Ceiling Normal Mode (0: Fan Voltage 0V, 255: Fan Voltage 25.5V)
135
Maximum Control Value for FAN1 at Ceiling Normal Mode
95
0~255
Minimum Control Value for FAN2 at Ceiling Normal Mode
125
Maximum Control Value for FAN2 at Ceiling Normal Mode
46
Control Start Temperature for FAN1 at Ceiling Eco Mode
52
Control End Temperature for FAN1 at Ceiling Eco Mode
46
0~255
Control Start Temperature for FAN2 at Ceiling Eco Mode
52
Control End Temperature for FAN2 at Ceiling Eco Mode
60
Minimum Control Value for FAN1 at Ceiling Eco Mode (0: Fan Voltage 0V, 255: Fan Voltage 25.5V)
120
Maximum Control Value for FAN1 at Ceiling Eco Mode
74
0~255
Minimum Control Value for FAN2 at Ceiling Eco Mode
-30-