applied)
BAT -
- Plug the connector of the charger into the right socket at the base of the transceiver. The battery symbol should
indicate the state of charge:
Bars moving
Steady
If the battery is totally discharged, the battery icon will start scrolling 2 to 3 minutes only after being connected to
charger.
Just after charger plugging a pre-charge current less than 100 mA can be observed during first seconds.
After few seconds a charge current ≥500 mA approx. has to be observed
- Unplug the charger
8.3.2
Current consumption
a) Check current_OFF :
When the mobile is OFF the current measured must be: 0.03 < I (mA) < 0.08
b) Check Current_ON
- Turn the mobile on.
During the ignition phase (the first seconds after pressing the ON Key) a current consumption around 55-
90mA can be observed.
On first display "PN", the current consumption changes in an range of 200 < I (mA) < 250
Remove the battery.
Gently slide the card out away from the Product
8.4

W@P Test Procedure

With regard to the mobile phones only four things can prevent the W@P applications to operate properly :
- means the battery is being charged.
- means the battery is fully charged.