Installing Line for Gas Logs
If installing an unvented gas log set, refer to statement
below:
Only unvented gas log sets which have been found
to comply with the Standard for Unvented Room
Heaters, ANSI Z21.11.2, are to be installed in this
fireplaces.
MHSC fireplaces are designed to accept a 1/2" (13 mm)
gas line for installation of an approved gas appliance.
(MHSC manufactures a wide variety of gas logs for use
in MHSC fireplaces.)
Be sure to have the appliance installed in accordance
with building codes.
Gas connection may enter from either left or right side
of the fireplace.
Locate appropriate gas line access hole in the outer
casing of fireplace and remove insulation from gas line
tube. (Fig. 28)
Hole in Outer Cas-
ing
Gas Line
Tube
Ceramic
Knockout
Hole in
Outer Cas-
ing
Fig. 28 Gas line access.
From inside the fireplace, locate the knockout on the
firebrick -- be sure you are on the appropriate or "gas
line" side of the fireplace. Using a flat bladed screw-
driver or small chisel and hammer, carefully tap around
the knockout until it loosens and falls out.
Install 1/2" (13 mm) certified gas pipe through opening.
After gas pipe installation is complete, use insulation
that was removed from gas line tube to repack space
around the pipe. Material should be inserted from
outside of the fireplace and packed tightly to totally seal
between the pipe and tube.
7412972
1"
(25mm)
.
Min
Supply Line
Repack Insulation
1/2" (13mm)
Ceramic Knock-
out
FP560MH
FP560MH
Gas line access
6/3/99 djt
BC36MH, BC42MH Woodburning Fireplace
NOTE: Gas pipe should not come in contact with
any wood structures until it has reached a point at
least one (1) inch away from fireplace side.-
NOTE: When installing an ANSI Z21.11.2 ventless ap-
pliance, the finishing material used for the mantel must
be rated at 250°F or greater.
BTU input of a gas appliance installed in fireplace
should be rated less than 100,000 BTU/hr.
Gas pipe installation is intended for connection to a
decorative gas appliance only when 1. incorporating
an automatic shutoff device and 2. complying with the
Standard for Decorative Gas Appliances for Installa-
tion in Vented Fireplaces (ANSI Z21.60) or CSA draft
requirements for Gas-Fired Log Lighters for Woodburn-
ing Fireplaces (Draft No. 4, August 1993)
Decorative gas appliance should be installed in accor-
dance with the National Fuel Gas Code, ANSI Z223.1
(latest edition).
CAUTION: When using decorative gas ap-
pliance, flue damper must be set in fully
open position. Glass doors must also be
fully opened.
WARNING: Do not operate an unvented gas
log set in this fireplace with the chimney
removed.
WARNING: When installing an unvented
gas log set, the MHSC model CABL or
CABR 4" adjustable hood must be used.
Fan/Blower FK-12
This fan kit is carefully engineered and must be in-
stalled only on the specified fireplaces. If you modify the
fan or any of its components, you may possibly create a
fire hazard and will void the warranty. In addition, such
action may void the coverage provided by the owner's
home insurance.
The junction box, on/off switch and fan/blower are fac-
tory installed. This system requires 110-120V AC be
wired to the factory installed junction box before the fire-
place is permanently installed. (Fig. 30)
After connecting 120V AC to the fireplace, test blower
operation. Turn the blower on by pushing the rocker
switch located on the lower right louver panel to "ON".
If the blower does not turn on, push switch to "OFF".
Unplug power cord. Check all wires and terminals for
proper connection. Plug in blower, retest.