High Shelving Filter; Master Level; Clip Indicator - Ashly PQX-571 Operating Manual

Ashly parametric equalizer operating manual pqx-571, pqx-572
Table of Contents

Advertisement

Operating Manual - PQX 571 and PQX 572 Parametric Equalizer
Parametric Filter Level Control
Parametric Filter Frequency Control
Parametric Filter Bandwidth Control
High Shelf Level Response
5.3
High Shelving Filter (Filter No. 7)
These concentric controls work the same way as
the low shelf controls described in (1) and (2) except the
filter response starts at the center frequency selected and
continues up in frequency.
5.4

Master Level

The overall gain of the equalizer is adjusted by
this control. The master level gain stage is placed prior
to any filter stages so that increasing the master level will
not amplify filter noise. If the Master EQ switch is out,
the level control has no affect. Signals are then simply
routed through the equalizer at unity gain.
5.5

Clip Indicator

This red LED illuminates when an amplifier in
any of the filters comes within 3 dB of clipping, includ-
ing those filters which are not engaged. The maximum
signal level through the PQX equalizers is greater than
+22 dBu.
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pqx-572

Table of Contents