Gas supply line
[]
1/2"
NPT pipe
is recommended.
[]
3/8"
approved
tubing
is acceptable
for lengths
under
20 ft. (6.1 m)
if local
codes
and gas supplier
permit.
[]
Must include
1/8"
NPT minimum
plugged
tapping
accessible
for test
gauge
connection,
immediately
upstream
of the gas connection
to
the dryer
(see illustration).
[]
Must include
a shut-off
valve:
In the U.S.A.:
An individual
manual
shut-off
valve
must be installed
within
six (6)
feet (1.8 m) of the dryer
in accordance
with
the National
Fuel Gas
Code,
ANSI
Z223.1.
In Canada:
An individual
manual
shut-off
valve
must be installed
in accordance
with
the B149.1, Natural
Gas and
Propane
Installation
Code.
It is
recommended
that an individual
manual
shut-off
valve
be installed
within
six (6) feet (1.8 m) of the dryer.
The shut-off valve location should be easy to reach for opening and
closing.
E
B
A. 3/8"
flexible
gas connector
B. 3/8"
pipe
to flare
adapter
fitting
C. 1/8"
NPT minimum
plugged
tapping
D. 1/2"
NPT gas
supply
line
E. Gas
shut-off
valve
Gas supply connection requirements
There
are many
methods
by which
your
gas dryer
can
be connected
to
the gas supply.
Listed
here are some
guidelines
for two different
methods
of connection.
Option I (Recommended
Method)
Flexible stainless steel gas connector:
If local
codes
permit,
use a new flexible
stainless
steel gas
connector
(Design
Certified
by the American
Gas Association
or CSA
International)
to connect
your
dryer
to the rigid
gas supply
line. Use
an elbow
and a 3/8"
flare
x 3/8"
NPT adapter
fitting
between
the
stainless
steel gas connector
and the dryer
gas pipe,
as needed
to
prevent
kinking.
Option 2 (Alternate
Method)
Approved aluminum or copper tubing:
[]
Lengths
under
20 ft. (6.1 m) can
use 3/8"
approved
tubing
(if codes and
gas supplier
permit).
[]
If you are
using Natural
Gas, do not use copper
tubing.
[]
3/8"
flare
x 3/8"
NPT adapter
fitting
between
dryer
pipe
and 3/8"
approved
tubing.
[]
Lengths
over
20 ft. (6.1 m) should
use larger
tubing
and a different
size adapter
fitting.
[]
If your
dryer
has been
converted
to use LP gas, 3/8"
LP compatible
copper
tubing
can be used.
If the total
length
of the supply
line is
more
than
20 ft. (6.1 m), use larger
pipe.
NOTE:
Pipe joint compounds
that
resist the action
of LP gas must be
used.
Do not use TEFLON _et tape.
Dryer
gas
pipe
[]
The gas pipe
that comes
out through
the rear
of your
dryer
has a
3/8"
male
pipe
thread.
y,,,"
A ....
_--
g¼"---_
(235 mm)
A. 3/8"
NPT dryer pipe
1¼"
(32 ram}
Burner input requirements
Elevations
up to 10,000
ft. (3,048
m):
[]
The design
of this dryer
is certified
by CSA international
for use at
altitudes
up to 10_000
ft. (3,048
m), above
sea level at the B.T.U.
rating
indicated
on the model/serial
number
plate.
Burner
input
adjustments
are not required
when
the dryer
is operated
up to this
elevation.
Elevations
above
10,000
ft. (3,048
m):
[]
When
installed
above
10,000
ft. (3,048
m) a 4%
reduction
of the
burner
B.T.U. rating
shown
on the model/serial
number
plate
is
required
for each
1,000
ft. (305
m) increase
in elevation.
Gas supply
pressure
testing
[]
The dryer
must be disconnected
from
the gas
supply
piping
system
during
pressure
testing
at pressures
greater
than
1/2 psi.