Cooling System; Air Filter - Husqvarna 345FR Operator's Manual

Hide thumbs Also See for 345FR:
Table of Contents

Advertisement

Cooling system

To keep the working temperature as low as possible the
machine is equipped with a cooling system.
The cooling system consists of:
1
Air intake on the starter.
2
Fins on the flywheel.
3
Cooling fins on the cylinder.
4
Cylinder cover (directs cold air over the cylinder).
Clean the cooling system with a brush once a week, more
often in demanding conditions. A dirty or blocked cooling
system results in the machine overheating which causes
damage to the piston and cylinder.
Air filter
The air filter must be regularly cleaned to remove dust and
dirt in order to avoid:
Carburettor malfunctions.
Starting problems.
Loss of engine power.
Unnecessary wear to engine parts
Excessive fuel consumption.
Clean the filter every 25 hours, or more regularly if
conditions are exceptionally dusty.
28 – English
MAINTENANCE
4
3
1
2
Check air filter (345FR, 545RX, 545RXT)
(paper filter)
Set the choke control in the choke position.
Remove the air filter cover and take out the filter.
Check and clean filter housing.
Check the filter and change if contaminated or
damaged. Use Husqvarna original filters.
IMPORTANT! Never bend or fold a filter as it can be
damaged. A damaged air filter must always be replaced.
Check air filter (545FX, 545FXT) (nylon
filter)
Set the choke control in the choke position.
Remove the air filter cover and take out the filter.
Check and clean filter housing.
Clean the filter if it is contaminated and change if
damaged. Clean the filter with warm soapy water. Use
Husqvarna original filters.
IMPORTANT! A damaged air filter must always be
replaced.

Hide quick links: