International comfort products N4A4 Technical Support Manual
International comfort products N4A4 Technical Support Manual

International comfort products N4A4 Technical Support Manual

Split system air conditioner

Advertisement

TECHNICAL SUPPORT MANUAL
Split System Air Conditioner
DANGER, WARNING, CAUTION, and
NOTE
The
signal
words
CAUTION, and NOTE are used to identify levels of
hazard seriousness. The signal word DANGER is
only used on product labels to signify an immediate
hazard. The signal words WARNING, CAUTION,
and NOTE will be used on product labels and
throughout this manual and other manuals that may
apply to the product.
DANGER − Immediate hazards which will result in
severe personal injury or death.
WARNING − Hazards or unsafe practices which
could result in severe personal injury or death.
CAUTION − Hazards or unsafe practices which
may result in minor personal injury or product or
property damage.
NOTE − Used to highlight suggestions which will
result in enhanced installation, reliability, or
operation.
TABLE OF CONTENTS
Wiring Diagrams
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Charging Chart
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tech Labels (Expanded Data)
Condenser Only Data
. . . . . . . . . . . . . . . . . . . . . .
Cooling Multipying Factors
Model Number Identification
MODELS
N4A418*KA300
N4A424*KB300
N4A430*KB300
N4A436*KA300
N4A442*KB300
N4A448*KB300
N4A449*KB300
N4A460*KB400
* = A for standard inlet grille,
G for inlet grille with 3/8" (10mm) tight−wire spacing
N4A4
Safety Labeling and Signal Words
DANGER,
WARNING,
. . . . . . . . . . . . . . . .
4 − 11
12 − 15
. . . . . . . . . . . . . . . . . .
16 − 22
. . . . . . . . . . . . . . . . . . . .
Signal Words in Manuals
The signal word WARNING is used throughout this
manual in the following manner:
WARNING
!
The signal word CAUTION is used throughout this
manual in the following manner:
CAUTION
!
Signal Words on Product Labeling
Signal words are used in combination with colors
and/or pictures on product labels.
WARNING
!
2
DEATH, PERSONAL INJURY, AND/OR PROPERTY
3
DAMAGE HAZARD
Failure to carefully read and follow this warning
could result in equipment malfunction, property
damage, personal injury and/or death.
23
Installation or repairs made by unqualified per-
sons could result in equipment malfunction, prop-
erty damage, personal injury and/or death.
The information contained in this manual is in-
tended for use by a qualified service technician fa-
miliar with safety procedures and equipped with
the proper tools and test instruments.
Installation must conform with local building
codes and with the National Electrical Code
NFPA70 current edition or Canadian Electrical
Code Part 1 CSA C.22.1.
WARNING
421 04 5202 00
Feb 2010

Advertisement

loading

Summary of Contents for International comfort products N4A4

  • Page 1 TECHNICAL SUPPORT MANUAL Split System Air Conditioner N4A4 Safety Labeling and Signal Words DANGER, WARNING, CAUTION, and NOTE Signal Words in Manuals The signal word WARNING is used throughout this signal words DANGER, WARNING, manual in the following manner: CAUTION, and NOTE are used to identify levels of...
  • Page 2 *CHS CONNECTION DIAGRAM SCHEMATIC DIAGRAM (LADDER FORM) COMP (NOTE #9) CONT COMP RED or BLK CONT CA P 208/230 1∅ EQUIP POWER *CHS SUPPLY CONT EQUIP (NOTE #8) BRN/YEL (NOTE #14) (NOTE #14) YEL/ BLU CONT *CTD *LPS *DTS *HPS *DTS *HPS *LPS...
  • Page 3 TECHNICAL SUPPORT MANUAL Split System Air Conditioner: N4A4 R−410A CHARGING CHART Rating Plate (required) Subcooling Temperature ° F (° C) ° F ° F ° F ° F (° C) (° C) (° C) (° C) (° C) (° C)
  • Page 4 18 Size Outdoor With ED*4X24B** Indoor Cooling Outdoor Ambient Temperature − Degrees F, Dry Bulb COOLING Entering Indoor Temperature − Degrees F, Wet Bulb MBh† 21.57 19.60 17.82 17.16 20.52 18.65 16.96 16.49 19.45 17.67 16.08 15.79 18.33 16.65 15.18 15.06 17.18 15.60 14.29 14.29 0.52 0.70 0.90...
  • Page 5 24 Size Outdoor With ED*4X24B** Indoor Cooling Outdoor Ambient Temperature − Degrees F, Dry Bulb COOLING Entering Indoor Temperature − Degrees F, Wet Bulb MBh† 27.67 25.12 22.88 22.21 26.44 23.98 21.86 21.39 25.16 22.80 20.79 20.53 23.80 21.54 19.69 19.60 22.34 20.19 18.60 18.60...
  • Page 6 30 Size Outdoor With ED*4X30B** Indoor Cooling Outdoor Ambient Temperature − Degrees F, Dry Bulb COOLING Entering Indoor Temperature − Degrees F, Wet Bulb MBh† 34.32 31.45 28.82 28.00 32.83 30.06 27.56 26.98 31.24 28.59 26.24 25.89 29.59 27.04 24.86 24.74 27.80 25.38 23.47 23.48...
  • Page 7 36 Size Outdoor With ED*4X42J** Indoor Cooling Outdoor Ambient Temperature − Degrees F, Dry Bulb COOLING Entering Indoor Temperature − Degrees F, Wet Bulb MBh† 42.83 38.83 35.34 34.26 40.92 37.06 33.74 32.98 38.92 35.20 32.07 31.63 36.78 33.22 30.32 30.17 34.47 31.08 28.58 28.58...
  • Page 8 42 Size Outdoor With ED*4X48* Indoor Cooling Outdoor Ambient Temperature − Degrees F, Dry Bulb COOLING Entering Indoor Temperature − Degrees F, Wet Bulb MBh† 47.98 43.86 40.13 39.05 45.92 41.96 38.41 37.67 43.69 39.91 36.57 36.17 41.29 37.70 34.63 34.53 38.70 35.31 32.73 32.74...
  • Page 9 48 Size Outdoor With ED*4X60L** Indoor Cooling Outdoor Ambient Temperature − Degrees F, Dry Bulb COOLING Entering Indoor Temperature − Degrees F, Wet Bulb MBh† 57.54 52.60 48.14 46.53 54.90 50.19 45.96 44.80 52.22 47.73 43.75 43.02 49.43 45.16 41.45 41.12 46.45 42.41 39.05 39.07...
  • Page 10 † ‡ † ‡ † ‡ † Total capacities are net (I.D. blower heat subtracted) system capacities based on 25’ line set. If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur. ††...
  • Page 11 60 Size Outdoor With ED*4X60L** Indoor Cooling Outdoor Ambient Temperature − Degrees F, Dry Bulb COOLING Entering Indoor Temperature − Degrees F, Wet Bulb MBh† 70.19 64.08 58.62 56.77 66.99 61.18 56.02 54.70 63.60 58.10 53.29 52.48 59.97 54.79 50.39 50.07 56.01 51.19...
  • Page 12 TECHNICAL SUPPORT MANUAL Split System Air Conditioner: N4A4 Data for Condenser Only (Cooling) Condenser Entering Air Temperature ° F Saturated Suction Temperature ° F N4A418AKA, N4A418GKA 16.80 15.70 14.70 13.80 12.80 11.80 10.80 9.70 66.70 76.10 85.40 94.80 104.30 113.70 123.20...
  • Page 13 TECHNICAL SUPPORT MANUAL Split System Air Conditioner: N4A4 Data for Condenser Only (Cooling) Condenser Entering Air Temperature ° F Saturated Suction Temperature ° F N4A430AKB, N4A430GKB 27.40 25.90 24.50 22.90 21.30 19.70 18.00 16.20 68.50 77.80 87.20 96.60 106.00 115.40 124.90...
  • Page 14 TECHNICAL SUPPORT MANUAL Split System Air Conditioner: N4A4 Data for Condenser Only (Cooling) Condenser Entering Air Temperature ° F Saturated Suction Temperature ° F N4A442AKB, N4A442GKB 37.40 35.70 33.80 31.80 29.70 27.40 25.00 22.50 68.10 77.60 87.00 96.40 105.80 115.20 124.60...
  • Page 15 TECHNICAL SUPPORT MANUAL Split System Air Conditioner: N4A4 Data for Condenser Only (Cooling) Condenser Entering Air Temperature ° F Saturated Suction Temperature ° F N4A449AKB, N4A449GKB 45.60 43.20 40.80 38.40 35.90 33.20 30.40 27.50 67.20 76.60 86.10 95.50 104.90 114.30 123.60...
  • Page 16 COOLING Multiplying Factors for other Indoor Combinations Indoor Furnace Indoor Furnace Indoor Furnace Capac. (MBh) Power (AMPS) Capac. (MBh) Power (AMPS) Capac. (MBh) Power (AMPS) Model Model Model Model Model Model N4A418 >ED*4X24B** 1.00 1.00 ED*4X24F** *9MVX040 1.03 0.91 EHD4X24A** *9MVX040 1.03 0.95...
  • Page 17 COOLING Multiplying Factors for other Indoor Combinations (continued) Indoor Furnace Indoor Furnace Indoor Furnace Capac. (MBh) Power (AMPS) Capac. (MBh) Power (AMPS) Capac. (MBh) Power (AMPS) Model Model Model Model Model Model ED*4X30F** *9MVX060 1.03 0.92 EHD4X24A** MV08B15**B* 1.01 0.89 EMA4X24D** 1.00 1.00...
  • Page 18 COOLING Multiplying Factors for other Indoor Combinations (continued) Indoor Furnace Indoor Furnace Indoor Furnace Capac. (MBh) Power (AMPS) Capac. (MBh) Power (AMPS) Capac. (MBh) Power (AMPS) Model Model Model Model Model Model ED*4X36F** MV12F19**B* 1.01 0.91 EHD4X30A** *8MPV075 1.01 0.94 EHD4X42A** *9MPV125 1.00...
  • Page 19 COOLING Multiplying Factors for other Indoor Combinations (continued) Indoor Furnace Indoor Furnace Indoor Furnace Capac. (MBh) Power (AMPS) Capac. (MBh) Power (AMPS) Capac. (MBh) Power (AMPS) Model Model Model Model Model Model ED*4X36J** MV16J22**B* 0.99 0.91 ED*4X48J** *8MPV125 1.01 0.93 EHD4X42A** MV08B15**B* 0.99...
  • Page 20 COOLING Multiplying Factors for other Indoor Combinations (continued) Indoor Furnace Indoor Furnace Indoor Furnace Capac. (MBh) Power (AMPS) Capac. (MBh) Power (AMPS) Capac. (MBh) Power (AMPS) Model Model Model Model Model Model ED*4X42F** *9MPV075 0.96 0.99 ED*4X48L** *8MPV100 1.00 0.96 EHD4X42A** 1.00 1.00...
  • Page 21 COOLING Multiplying Factors for other Indoor Combinations (continued) Indoor Furnace Indoor Furnace Indoor Furnace Capac. (MBh) Power (AMPS) Capac. (MBh) Power (AMPS) Capac. (MBh) Power (AMPS) Model Model Model Model Model Model N4A448 >ED*4X60L** 1.00 1.00 ED*4X60J** *9MPV100 1.00 0.96 EHD4X48A** 0.98 0.98...
  • Page 22 COOLING Multiplying Factors for other Indoor Combinations (continued) Indoor Furnace Indoor Furnace Indoor Furnace Capac. (MBh) Power (AMPS) Capac. (MBh) Power (AMPS) Capac. (MBh) Power (AMPS) Model Model Model Model Model Model ED*4X48J** *9MVX080 0.97 0.97 ED*4X60L** *8MPV125 1.00 0.96 EHD4X60A** 1.00 1.00...
  • Page 23 TECHNICAL SUPPORT MANUAL Split System Air Conditioner: N4A4 OUTDOOR UNIT MODEL NUMBER IDENTIFICATION GUIDE (single phase) Digit Position: 5, 6 Example Part Number: Product Family 4 = R−410A REFRIGERANT A = Air Conditioner H = Heat Pump TYPE 3 = 13 SEER...