Shutting Down Your Furnace; Performing Routine Maintenance - Bryant 315AAV048090 User's Information Manual

Table of Contents

Advertisement

NOTE: If the main burners fail to ig-
nite, the furnace control system will go
through 3 more ignition cycles. Then,
if burners fail to ignite, the system will
lockout. If lockout occurs, or the
blower doesn't come on—shut down
your furnace and call your dealer for
service.
13. Set your thermostat to the tempera-
ture that satisfies your comfort re-
quirements. SUGGESTION:
Setting the thermostat back a few
degrees—and compensating for the
difference with warmer clothing—
can make a big difference in your
fuel consumption on extremely
cold days. The few degrees at the
top of your thermostat "comfort
level'' are the most costly degrees
to obtain.
When the room temperature drops
below the temperature selected on
the thermostat, the furnace will be
switched on automatically. When the
room temperature reaches the degree
selected on the thermostat, the furnace
will be switched off automatically.
Continuous Fan -Some thermostats
have a "fan'' mode with 2 selections:
AUTO or ON. When set on AUTO, the
furnace blower cycles on and off, con-
trolled by the thermostat. In the ON
position, the furnace blower runs con-
tinuously except for a 42-62 sec delay
at the "call for heat.'' This keeps the
temperature level in your home more
evenly balanced. It also continuously
filters the indoor air.
FanOn PLUS™ -On all but the
310AAV or 310JAV, the blower
speed can be increased or de-
creased if desired due to change of
seasons, large gatherings in your
home, etc. Simply change your
"FAN" switch from "on" to "off"
(or "auto" depending on your ther-
mostat), and then return to "on."
The blower will switch to the next
highest speed. There are at least 3
speeds to choose from. If the blower is
running on its highest speed, a request
to change will direct the blower to re-
turn to its lowest speed.
SHUTTING DOWN
YOUR FURNACE
Should you ever suspect a malfunction
in your furnace, you will need to turn
13
the furnace off. The following proce-
dures must be followed:
1. Set your room thermostat to
the lowest temperature setting.
(See Fig. 14.)
2. Close the external manual gas
valve. (See Fig. 6 on page 4.)
3. Turn OFF the electrical supply to
your furnace. (See Fig. 15.)
4. Remove the outer door on your fur-
nace. (See Fig. 8.)
5. Turn the control switch on the gas
valve to the OFF position. (See
Fig. 16.
5
6. Replace the outer door. (See Fig.
11.)
7. If the furnace is being shut down
because of a malfunction, call your
dealer as soon as possible.
PERFORMING
ROUTINE
®
MAINTENANCE
With the proper maintenance and care,
your furnace will operate economically
and dependably. Basic maintenance,
which can easily be accomplished by
someone who follows the directions, is
found on this and the following pages.
14
However, before beginning mainte-
nance, follow these safety precautions:
WARNING
!
Turn off electrical power sup-
ply to your furnace before re-
moving the access doors to
service or perform mainte-
nance. A failure to follow this
warning could result in per-
sonal injury or death.
CAUTION
!
15
Although special care has
been taken to minimize sharp
edges, be extremely careful
when handling parts or reach-
ing into the furnace.
OR
16

Advertisement