Conversion To A Different Type Of Gas - Bosch WR11B series Installation Manual And Operating Instructions

Gas instantaneous water heater
Table of Contents

Advertisement

Injector code
Connection
pressure
(psi)
MAX (psi)
Table 8
Burner pressure
6.3

Conversion to a different type of gas

Only use the original conversion kits.
The conversion must only be performed by a qualified
technician. The original conversion kits are supplied with
assembly instructions.
Adjustments (must be carried out only by qualified technicians) | 17
Natural gas H
8708202113
(1,10)
WR11
8708202124
(1,20)
8708202113
(1,10)
WR14
8708202116
(1,25)
8708202115
(1,15)
WR18
8708202116
(1,25)
WR11
WR14
WR18
WR11
WR14
WR18
2
1,27
1,2
1,03
Butane
Propane
8708202130
(0,70)
8708202128
(0,72)
8708202128
(0,72)
8708202132
(0,75)
8708202130
(0,70)
8708202132
(0,75)
3
2,8
2,8
2,55
3,25
6 720 648 592 (2011/06)
3
3,5
3,5

Hide quick links: