Vax HF85-FM-C User Manual
Vax HF85-FM-C User Manual

Vax HF85-FM-C User Manual

Floormate cordless

Advertisement

FLOORMATE
Let's get started
vax.co.uk
HF85-FM-C/HF85-FM-CA

Advertisement

Table of Contents
loading

Summary of Contents for Vax HF85-FM-C

  • Page 1 FLOORMATE Let’s get started vax.co.uk HF85-FM-C/HF85-FM-CA...
  • Page 2: Let's Talk Safety

    • Always replace the fuse in the plug with a British 13amp fuse. • Use only the battery (Vax part no. BH03120UK) supplied by Vax. Other batteries may burst causing serious personal injury or damage.
  • Page 3 Not suitable for use on water sensitive flooring. • Replace battery with Vax battery only. Use of another battery may present a risk of fire or explosion. • Prior to disposal, protect exposed terminals with heavy insulating tape to prevent shorting.
  • Page 4 Maintaining your hard floors will ensure they keep their appearance for longer. You’ve chosen hard floors for your home for a reason and Vax will help you take good care of them. Taking care of your Floormate Cordless Also inside this guide are instructions on maintaining your new machine, so that it’s always ready...
  • Page 5: Table Of Contents

    Contents Floormate Cordless Included with your machine Let’s talk safety 250ml Floor to Floor Getting to know your machine Detergent Getting started SpinScrub Wood Floor Brush Using your machine 1x LithiumLife Battery (dependant on model*) Taking care of your machine Battery Charger What to do if it goes wrong (dependant on model*)
  • Page 6: Getting To Know Your Machine

    Release Button Clean Water/ Dirty Water Tank Detergent Tank Handle Release Nozzle Release Latch Pedal Brush Release Buttons Nozzle HF85-FM-C HF85-FM-CA Technical Specification Battery Specification Technical Specification Name Floormate Cordless Type Lithium-Ion rechargeable Name Floormate Cordless battery pack Battery voltage 20V Weight 5.4kg...
  • Page 7: Getting Started

    Getting started PLEASE READ ‘LET’S TALK SAFETY’ AT THE BEGINNING BEFORE USE. Raise handle to upright Pull the nozzle release Lie your Floormate Line up and push nozzle position until it clicks and latch upwards and Cordless on its back. Line until clicks into place.
  • Page 8: Charging The Battery

    (60° C/140°F) or incinerate. Replace battery with Vax battery only. Use of another battery may present a risk of fire or explosion. Dispose of used battery promptly. Keep away from children. Do not disassemble and do not dispose of in fire. Do not attempt to disassemble the battery or remove any component projecting from the battery terminals.
  • Page 9: Using Your Machine

    Using your machine IMPORTANT: Only use Vax hard floor cleaning detergent. Using other solution may cause excess foaming. Excessive foaming will prevent the machine from working effectively. Using other detergents will invalidate the guarantee. Filling the clean water tank Press the release button...
  • Page 10 Using your machine IMPORTANT: Please refer to floor manufacturer’s care recommendations before use, and test your flooring by running the Floormate Cordless over a small hidden area. If no damage or discolouration has occurred once the area is dry, continue cleaning. Not suitable for use on water sensitive flooring. Vacuum your hard floor thoroughly prior to using your Floormate Cordless.
  • Page 11: Taking Care Of Your Machine

    Taking care of your machine IMPORTANT: Remove battery before carrying out any maintenance on your machine. NOTE: The dirty water tank has an automatic shut off to prevent the tank from overflowing. If this is activated, the Floormate Cordless will not pick up and the sound of the motor will change. The dirty water tank will need to be emptied.
  • Page 12 Taking care of your machine IMPORTANT: Remove battery before carrying out any maintenance on your machine. Cleaning the nozzle Pull the nozzle release latch Remove nozzle from Remove any debris from up and forward. Floormate Cordless and rinse squeegee by wiping with under running water a damp cloth.
  • Page 13 Taking care of your machine Cleaning terminals Using a dry cloth or soft dusting brush remove any dust/debris from terminals on battery charger, battery and Floormate Cordless. Carrying and storage To lower handle, press handle The Floormate Cordless can be release button and fold moved by lifting the carry handle handle to storage position.
  • Page 14: What To Do If It Goes Wrong

    What to do if it goes wrong Problem Solution There is an • Check the ‘This pack contains’ panel on the box to make sure accessory missing. the part is definitely included in your unit. • Check the fuse in the charger plug. Always replace the fuse in the Why won’t the plug with a British 3amp fuse.
  • Page 15: Getting In Touch

    Getting in touch * Calls are charged at the UK local rate. Please make a note of the serial number and model number of the product before calling. † Registration Required. Terms and conditions apply.
  • Page 16: Accessories

    Floor to Floor Cleaning Detergent 1.5l (x1) 1-9-132708-00 Vax Floor to Floor hard floor cleaning detergent gently removes tough spots and stains from your hard floors. Floor to Floor cleans and shines with no dulling residue. Safe to use on sealed laminates, hard floors and tiles.
  • Page 17 Notes...
  • Page 18 Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority or retailer for recycling advice. © 2014 All rights reserved. VAX®, VAX Lozenge are trade marks or registered trade marks of Techtronic Floor Care Technology Ltd.

This manual is also suitable for: