Printed Circuit Board; Circuit Check Procedure - Daewoo N230S Service Manual

Table of Contents

Advertisement

PRINTED CIRCUIT BOARD

1. CIRCUIT CHECK PROCEDURE

1. Low Voltage Transformer check
• The low voltage transformer is located on the P.C.B.
• Measuring condition: input voltage : 230V/Frequency : 50Hz
Terminal Voltage
4-7
NOTE :
1. Refer to Circuit Diagram (point 4).
2. Secondary side voltage of the low voltage transformer changes in proportion to fluctuation of power source voltage.
3. The allowable tolerance of the secondary voltage is within ± 5% of nominal voltage.
2. Voltage check
• Key check point
NO
CHECK POINT
1
IC 1 PIN 2, 21, 30, 34
2
IC 1 PIN 35
3
IC 1 PIN 31 OR 32
• Check method
NO
MEASURE POINT
1
MP1
2
MP2
NOTE :
Each measure point must be measured with GND point.
LOAD
AC 12.6 V
0V
-5V
0V
-5V
WAVE FORM
DC -5V±0.25V
DC -12V±2.0V
25
NO LOAD
AC 14.7 V
REMARK
-5 VDC
T:20ms(50Hz)
T:250ns(4MHz)
REMEDY
Replace VL1, EC1
Replace EC2, D12, 13, 14
REMARK
NO LOAD
NO LOAD

Advertisement

Table of Contents
loading

Table of Contents