Fit Boiler Casing - Vaillant aquaPlus Instructions For Installation And Servicing

Gas fired room sealed fan assisted combination boiler with intergrated 15 litre power store
Hide thumbs Also See for aquaPlus:
Table of Contents

Advertisement

7.8 Fit boiler casing

• Carefully push case (1) onto the boiler such that the
locating points either side at the top of the boiler
engage. Push the casing onto the securing clips at the
bottom of the boiler.
• Close control panel (2).
• Secure control panel by turning both securing
fasteners (3) clockwise by 90°.
• Close front door (4).
• Open the punch-out holes in the cover panel (6) for
the pipework installation.
• Fit the bottom cover (6).
1
90¡
Fig. 7.6: Fit boiler casing
Instructions for installation and servicing aquaPLUS VUI 362-7
Supplied by HeatingSpares247.com
Gas supply adjustments (Commissioning Part II) 7
2
90¡
3
VRC-VC
I
0
4
6
31

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aquaplus seriesAquaplus vui 362-7