LOCAL CODES

Install and use fireplace with care. Follow all
local codes. In the absence of local codes, use
the latest edition of The National Fuel Gas
Code ANS Z223.1, also known as NFPA 54*.
Firebox must be electrically grounded in
accordance with the National Electrical Code,
ANS/NFPA70 (latest edition).
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
UNPACKING
1. Use utility knife to cut carton all the
way around above the staples on the
bottom tray. Lift carton off the firebox
and discard.
2. Remove all protective packaging from
inside firebox.
3. Check carton contents for the
following:
• Screen assembly
• Screen support rod
• Hardware and parts bag containing
the following:
- Owners Operation and Installation
Manual
- 2 - Black #10 x 3/8" Phillips
screws for mounting screen
support rods
If any items are missing, inform dealer
where you bought firebox.
4. Check all items for any shipping dam-
age. If damaged, promptly inform
dealer where you bought firebox.
Notice: The firebox identification
label (including model number,
serial number, clearances, etc.)
is on the left front edge of the
firebox. See Figure 14, page 11)
105161
PRODUCT
FEATURES
Operation
This firebox is designed for use with ap-
proved ANS Z21.11.2 decorative type
unvented room heaters. (Physical size limi-
tations apply. Refer to minimum firebox
requirements supplied with log heater.) It
requires no outside venting or chimney mak-
ing installation easy and inexpensive. When
used without the blower, the firebox requires
no electricity making it ideal for emergency
back-up heat.
Blower Accessory
The CGFB36C firebox will accept the
GA3750 accessory. The variable blower
allows you to select the fan speed you de-
sire. The blower circulates heated air from
the firebox into the room. Use of blower is
optional.
Brick Liner
This firebox features a concrete brick liner.
As with all concrete liners, this liner may
develop slight cracks when exposed to heat.
These cracks will not affect the perfor-
mance of the fireplace or vent-free gas logs.
3
OWNER'S MANUAL
LOCATING
FIREBOX
Planning
Plan where you will install the firebox. This
will save time and money later when you
install the firebox. Before installation, con-
sider the following:
1.
Where the firebox will be located. Al-
low for wall and ceiling clearances (see
Installation Clearances, page 8).
2.
Everything needed to complete instal-
lation.
3.
These models CANNOT be installed
in a bedroom or bathroom.
4.
Proper air for combustion and ventila-
tion (page 5).