Perkins 4.108 Workshop Manual page 23

Hide thumbs Also See for 4.108:
Table of Contents

Advertisement

I
I
I
",-(I!I'"
I
Atomisers
4.108 Veh., M., Ind., Comb.
4.107 M.,
Ind., TA
Make
...
Holder Type
Nozzle Type
Code Letter
Min. Working Pressure
Setting Pressure
4.108M, Ind., Comb.
Make ...
Holder Type
Nozzle Type
Code Letter
!
Min. Working Pressure
I
Setting Pressure
CAV.
BKB40S05224
BON 12S06236
BG
TECHNICAL DATA-B.13
135 atm (2000 Ibflin2 or 140 kgf/cm2)
150 atm (2200 Ibf/in2 or 155 k9f1cm2)
CAV.
BKB40S05224
BDN4SD6769
GY
135 atm (2000 Ibflin 2 or 140 kgflcm2)
150 atm (2200 Ibflin 2 or 155 kgflcm2)
Note: Earlier atomisers bearing the identification code letter 'J' had a setting pressure of 140 atm. When servicing of
these atomisers is carried out, they should be reset in accordance with the settings quoted above.
Make
Holder Type
Nozzle Type
Code Letter
Min. Working Pressure
Setting Pressure
Starting Aid
Make
Type
Voltage
Maximum Current Consumption
Fuel Flow Rate through Unit
Height of Reservoir (where fitted) above Centre of
Thermostart
...
Make
...
Type
...
Max. Output
Alternator
Make
Type
...
Max. Output (hot)
AC5 (12V)
AC5 (24V)
11AC (12V)
..
11AC (24V)
15ACR
17ACR
Starter Motor
Make
...
Type
...
Max. Current
Starter Cable Resistance ...
No. of Teeth on Pinion
...
4.99 Veh
4.99 Veh
4.99 Ind.
&
4.107 Ind.
CAV.
CAV.
CAV.
BKB40S5223
BKB40S5224
BKB40S5224
BON12SD6236
BDN12SD6236 BDN4S6157
BK
120
130
CAV.
Thermostart
12 Volt
BL
125
130
12.9 Amperes at 11.5 Volts
4.3-4.9 cm
3
min at 70"F (21'C)
4.5-10 in (11,4-25,4 cm)
Lucas
C40
11A
Lucas or C.A.V.
BE
130
135
AC5 (12Vor24V), 11AC (12Vor24Vj,
15ACR (12V) and 17ACR (12V)
53A
30A
43A
23A
28A
36A
Lucas
MG45 or 2M113
900A
0.0017 ohms (Max.)
10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

4.994.107

Table of Contents