Table 5-3. Names and .unctions of Main Dialog Box Components
No.
Name
• This button toggles the display language for the
1
Switch of language
dialog box between Japanese and English.
• Indicates the scanner models which can be selected.
The list data can be changed using the Add and
Delete buttons.
Scanner Model
2
Selection List
• The following four models appear in the initial data
list: SCANNER ES-9000H, SCANNER GT-10000,
SCANNER ES-6000, SCANNER GT-30000
Additional model
• Used for entering the model name hen adding new
3
display area
models.
• Click this button to add the new scanner model which
4
Add button
appears in the additional model display area to the
end of the scanner model selection list.
• Click this button to delete the currently-selected
5
Delete button
scanner model from the scanner model selection list.
• Used for displaying and entering the main scanning
Main scanning
correction value. The valid range of data that can be
6
correction value
entered is within the range of 0 to 84 (multiples of 4
display area
only).
• Used for displaying and entering the sub scanning
Sub scanning
correction value. The valid range of data that can be
7
correction value
entered is within the range of 0 to 248 (multiples of 8
display area
only).
• Click this button to read the EEPROM data and
display it on the screen.
8
Read button
• After writing data, you can read it again to check the
written data on-screen.
9
End button
• Click this button to close the program.
• Click this button to write the edited data which is
being displayed on-screen into the EEPROM.
10
Write button
• After writing data, you can read it again to check the
written data on-screen.
• Used for displaying the number of scans.
Scanning .requency
11
(times) display area
NOTE: Impossible of writing
ADJUSTMENTS
.unction
Adjustments Using the Special Software
Table 5-3. Names and .unctions of Main Dialog Box Components
No.
Name
0 Clear (Zero clear)
• Click this button to reset the number of scans or the
12
button
number of pages fed by the AD. to zero.
• Click this button to reset all data for number of scans,
13
All Clear button
AD. paper feed, main scanning correction value and
sub scanning correction value to zero.
• Shows the number of pages fed by the AD..
AD. paper feed
14
display area
NOTE: Impossible of writing
Document detection
• Shows the document detection specifications. The
15
specifications
two types of specifications available are "B5" and
selection list
"EXE".

5.3.3 Using the Name Rewriting Software

5.3.3.1 Starting the Name Rewriting Software

1. Copy the folder of Rewrite Software from the CD-ROM to your local PC.
2. Run the startup file. (Double-click on CmdRW.exe.)
3. When automatic enabling of the device is complete, the EEPROM data will
be read and displayed on the screen.
If the scanner is not connected, a connection error message
C H E C K
will appear. Click OK to end the process.