13,000 BTU (LP). Models: RGA720EK - 20-in. Electronic Ignition RGA720PK - 20-in. Standing Pilot RGA724EK - 24-in. Electronic Ignition RGA724PK - 24-in. Standing Pilot GE Appliances General Electric Company Louisville, Kentucky 40225 GE CONFIDENTIAL AND PROPRIETARY INFORMATION – NOT FOR PUBLIC DISCLOSURE...
MANIFOLD PANEL SWITCH REMOVAL There are 8 screws that hold the manifold panel in 1. Prop open the cooktop. place. 2. Remove the gas control knobs, then remove the 4 Screws (Top and Bottom of the Manifold Panel) manifold panel. 3.
5. Push orifi ce down through burner box and SPARK ELECTRODES remove the tube assembly from the range. The range has 2 spark electrodes. They have different part numbers due to wire length. The wires are held in a retaining clip below the burner box. The burner box must be removed to route the wires correctly when replacing an electrode.
OVEN CAPILLARY BROILER DOOR REMOVAL The oven capillary is held in by 2 clips. To remove Open the broiler door and insert a pin into each the capillary, squeeze both clips at the same time door hinge as shown. Remove the 2 Phillips head and gently pull the capillary away from the oven screws from each hinge.