Starting up and operation
6.1.3

Rear of server

Global Error, ID and CSS indicators
Figure 18: Global Error and CSS indicators
1
Global Error indicator (yellow) on the system board, visible through
the chassis perforation.
– Lights up yellow if a prefailure event has been detected that
requires (precautionary) service intervention.
– Flashes yellow if an error was detected that requires service
intervention.
– Does not light up if there is no critical event.
If the event is still acute after a power cycle, the indicator is
activated after the restart.
The indicator also lights up in standby mode.
You can find more details on the indicated errors in the System
Event Log (SEL), in the ServerView Operations Manager or via the
iRMC S4's Web interface.
ID indicator (blue) on the system board, visible through the chassis
perforation.
Lights up blue when the system has been selected by pressing the
ID button. To deactivate, press the button again.
The ID indicator can also be activated via the ServerView
Operations Manager and the iRMC S4 Web interface and its status
reported to the ServerView Operations Manager and to the
iRMC S4.