PILOT BURNER ADJUSTMENT

Adjust the pilot screw to provide properly sized flame. Turn
in a clockwise direction to reduce the gas flow.
FIGURE 50
PILOT SCREW
THERMOPILE
THERMOPILE
PILOT
BURNER
THERMO-
COUPLE
ELECTRODE
FLAME MUST ENVELOP
UPPER 3/8" TO 1/2" OF
THERMOCOUPLE &
THERMOPILE

ORDERING REPLACEMENT PARTS

Contact your dealer or the factory for questions concerning
prices and policies on replacement parts. Normally all parts
can be ordered through your Napoleon dealer or distribu-
tor.

ADJUSTMENTS

FIGURE 51

REPLACEMENTS

VENTURI ADJUSTMENT

Natural gas models have air shutters set at 3/16 (.188")
inch open. Propane gas models have air shutters set at 3/
8 (.375) inch open. Closing the air shutter will cause a
more yellow flame, but can lead to carboning. Opening the
air shutter will cause a more blue flame, but can cause
flame lifting from the burner ports. The flame may not ap-
pear yellow immediately; allow 15 to 30 minutes for the
final flame colour to be established.
AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A
QUALIFIED GAS INSTALLER!
When ordering replacement parts always give the follow-
ing information:
1. Model & Serial Number of the unit.
2. Installation date of the unit.
3. Part Number
4. Part Description
5. Finish