Gas Adjustment; Appliance Maintenance - Hoover HPF90X Instruction Booklet

Table of Contents

Advertisement

L
N
IMPORTANT
The wires in the mains lead are coloured in accordance with the
following code:
GREEN AND YELLOW......EARTH
BLUE .................................NEUTRAL
BROWN .............................LIVE
REPLACEMENT OF THE CABLE
In case the cable is damaged, replace it in accordance with the
following instructions:
- open the box of the supply board as described on the picture
below;
- unscrew screw "A" fixing the cable;
- replace the cable with one of the same lenght and in accordance
with the features described on the table; switch the appliance
off, and close the gas tap
- the 'green-yellow" earth wire must be connected to the terminal
"
" and it must be about 10 mm longer thean the live wires;
- the "blue" neutral wire must be connected to the terminal marked
with letter "N";
- the live wire must be connected to the terminal marked with letter
"L".

GAS ADJUSTMENT

Conversion to LPG
Always isolate the cooker from the electricity supply, turn off the
gas supply temporarily and proceed as follows.
- change the injectors,
- adjust the minimum flow of the burners.
REPLACEMENT OF WORK-TOP INJECTORS
In order to change the work-top injectors, it is necessary to act as
follows: remove the grids, remove burners and flame-spreaders
(see fig.A), change the injector (see fig.B) and replace it with
another one suitable for the new type of gas (see table D). Re-
assemble everything in the opposite direction, paying attention to
place the flame-spreader in the right way on the burner.
A
1
2
3
4
5
A
B
GB
TAB. D
Kind of gas
mbar Nozzle
mm/100
115
NATURAL
20
128
G.P.L.
30
BUTANE
28
PROPANE
37
MINIMUM FLOW ADJUSTMENT FOR WORK-TOP TAPS
In order to adjust the minimum, act as follows: switch the burner
on, and turn the knob towards the minimum flow position
Remove the knob from the tap, introduce a little screwdriver in the
tap rod (fig. 11).
Attention: in taps with security valve, the minimum adjusting screw
"Z" is placed outside the rod tap (fig. 12).
Fig. 11
Unscrew the adjusting screw in order to increase the flow or screw
it to decrease the flow.
The right adjustment is obtained when the flame has a length of
about 3 or 4 mm.
For butane/propane gas, the adjusting screw must be tight screwed.
Make sure that the flame does not go out passing quickly from
the max. flow
to the minimum flow
Assemble the knob again.

APPLIANCE MAINTENANCE

WARNINGS
Isolate the cooker from the electricity supply before attempting to
replace the oven lamp.
The oven lamp used is of a special type withstanding high
temperatures. To replace it, act as follows: disassemble the
protecting glass (A) and replace the burnt lamp with one of the
same type. Reassemble the protecting glass.
18
GENERAL INJECTORS TABLE
Burners
Power Watt
Posizione-type
max.
min.
-Rapide
3000
97
-Semi rapide
1750
72
-Auxiliary
1000
-Triple crown
3300
1300
85
-Rapide
3000
65
-Semi rapide
1750
50
-Auxiliary
1000
93
-Triple crown
3300
1300
Z
Fig. 12
.
E 14
25 W - 230 V~
T300°C
A
Consum.
max.
750
286 l/h
480
167 l/h
330
95 l/h
315 l/h
750
219 g/h
480
128 g/h
330
73 g/h
241 g/h
.