Installer Setup
Name
1-daylight savings is on (factory setting).
Daylight Savings
0-daylight savings is off.
0-no remote temperature sensor.
1-outdoor temperature sensor for display only.
Remote
2-outdoor temperature sensor for control.
Temperature
Outdoor sensor used for Heat Pump Lockout
Sensor (Outdoor or
settings. (See Heat Pump Temperature Lockout
Indoor)
section for more details.).
3-indoor temperature sensor.
0-no compressor lockout.
15°F (-9.5°C)
20°F (-6.5°C)
Heat Pump
25°F (-4°C)
Compressor
Lockout or (Balance
30°F (-1°C)
Point)
35°F (1.5°C)
40°F (4.5°C)
45°F (7°C)
CT1001/CT1002 Touchscreen Programmable Thermostat
Table 3. Installer Setup Menu. (CONTINUED)
Settings
Notes
Set to 0 in areas that do
not follow daylight
savings.
Defaults and Options
depend on System Type
selection.
Indoor Temperature
Sensor uses an averaging
network and does not
include on-board sensor.
Default depends on other
selections. Shown if
control is selected. (See
section for more
information.)
Initial
Setting
Record
54