Toshiba RAS-13UKHP-ES4 Service Manual page 47

Split wall type
Table of Contents

Advertisement

8-4-4. Piping and drain hose installation
<Piping and drain hose forming>
* Since dewing results in a machine trouble, make
sure to insulate both the connecting pipes. (Use
polyethylene foam as insulating material.)
Rear right
Rear left
Bottom left
Left
Bottom right
Right
1. Die-cutting Front panel slit
For leftward connection, cut out slit on the left side of
the front panel. (A knife will produce splinters, so use
nippers.)
2. Changing drain hose
For leftward connection, bottom leftward connection
and rear leftward connection's piping, it is necessary to
change the drain hose and drain cap.
How to remove the drains cap
Clip drain cap by needle-nose plier, and pull out.
Fig. 8-4-10
How to install the drain hose
Firmly insert drain hose connecting part until hitting on
a heat insulator.
Heat insulator
Fig. 8-4-11
Drain hose
How to fix the drains cap
1) Insert hexagonal wrench (4 mm) in a center
head.
4 mm
2) Firmly insert drains cap.
No gap
Insert a hexagon
wrench (4 mm)
CAUTION
Firmly insert the drain hose and drain cap; otherwise,
water may leak.
<In case of right or left piping>
• After scribing slits of the front panel with a knife or a
making-off pin, cut them with a pair of nippers or an
equivalent tool.
Slit
<In case of bottom right or bottom left piping>
• After scribing slits of the front panel with a knife or a
making-off pin, cut them with a pair of nippers or an
equivalent tool.
Slit
− 46 −
FILE NO. SVM-05020
Fig. 8-4-12
Do not apply lubricating oil
(refrigerant machine oil) when
inserting the drain cap.
Application causes deterioration
and drain leakage of the plug.
Fig. 8-4-13
Fig. 8-4-14
Fig. 8-4-15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents