Introduction - Bryant 350MAV Installation, Start-Up, And Operating Instructions Manual

Series e &f deluxe 4–way multipoise fixed-capacity direct-vent condensing gas furnace
Table of Contents

Advertisement

15
26
"
16
1
26
"
4
1
24
"
2
5
22
"
16
2-IN. COMBUSTION-
AIR CONN
1
-IN. DIA
2
GAS CONN
2-IN. VENT CONN
1
-IN. DIA THERMOSTAT
2
ENTRY
11
22
"
16
1
14
"
SIDE INLET
2
TYP
1
1
"
4
1
1"
23
" TYP
4
SIDE INLET
15
26
" TYP
16
UNIT SIZE
040-08
040-12
060-08
060-12
060-16
080-12
080-16
080-20
100-16
100-20
120-20
140-20
CAN/CGA-B149.1- and .2-M95 National Standard of Canada,
Natural Gas and Propane Installation Codes (NSCNGPIC). Wear
safety glasses and work gloves. Have a fire extinguisher available
during start-up and adjustment procedures and service calls.
Recognize safety information. This is the safety-alert symbol
When you see this symbol on the unit and in instructions or
manuals, be alert to the potential for personal injury.
Understand these signal words; DANGER, WARNING, and
CAUTION. These words are used with the safety-alert symbol.
DANGER identifies the most serious hazards which will result in
severe personal injury or death. WARNING signifies hazards
which could result in personal injury or death. CAUTION is used
to identify unsafe practices which would result in minor personal
injury or product and property damage. NOTE is used to highlight
suggestions which will result in enhanced installation, reliability,
or operation

INTRODUCTION

The model 350MAV, Series E and F Furnaces are available in
sizes 40,000 through 138,000 Btuh input capacities.
CONDENSATE DRAIN
TRAP LOCATION
(DOWNFLOW &
HORIZONTAL LEFT)
7
-IN. DIA
8
POWER CONN
32
13
30
"
16
7
-IN. DIA
8
ACCESSORY
11
29
"
16
POWER ENTRY
TYP
5
27
"
8
CONDENSATE
DRAIN TRAP
9
27
"
16
LOCATION
TYP
(ALTERNATE
24
1
"
2
UPFLOW)
5
17
"
16
9
7
"
16
TYP
CONDENSATE
DRAIN LOCATION
(UPFLOW)
NOTES: 1. Minimum return-air openings at furnace, based on metal duct. If flex duct is used,
see flex duct manufacturer's recommendations for equivalent diameters.
2. Minimum return-air opening at furnace:
a. For 800 CFM–16-in. round or 14
b. For 1200 CFM–20-in. round or 14
c. For 1600 CFM–22-in. round or 14
d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data
literature for specific use of single side inlets. The use of both side inlets, a
combination of 1 side and the bottom, or the bottom only will ensure adequate
return air openings for airflow requirements above 1800 CFM.
DIMENSIONS (IN.)
A
17-1/2
17-1/2
17-1/2
17-1/2
17-1/2
17-1/2
17-1/2
21
21
21
24-1/2
24-1/2
Fig. 2—Dimensional Drawing
AIRFLOW
A
13
D
13
"
16
OUTLET
CONDENSATE DRAIN
HORIZONTAL RIGHT)
1
1
33
"
4
TYP
5
"
8
TYP
INLET
11
11
"
E
16
/
x 12-in. rectangle.
1
2
1
/
x 19
1
/
-in. rectangle.
2
2
/
x 23
/
-in. rectangle.
1
1
2
4
D
15-7/8
15-7/8
15-7/8
15-7/8
15-7/8
15-7/8
15-7/8
19-3/8
19-3/8
19-3/8
22-7/8
22-7/8
The 350MAV Multipoise Condensing Gas-Fired Furnaces are
C.S.A. (A.G.A. and C.G.A.). certified for natural and propane
gases and for installation in alcoves, attics, basements, closets,
utility rooms, crawlspaces, and garages. The furnace is factory-
shipped for use with natural gas. A C.S.A. (A.G.A. and C.G.A.)
.
listed gas conversion kit is required to convert furnace for use with
propane gas. The 350MAV 040 through 120 size units are C.S.A.
(A.G.A. and C.G.A.) approved for use in manufactured (mobile)
homes when factory accessory conversion kit is used. The 140 size
unit is NOT approved for use in manufactured (mobile) homes.
These furnaces are suitable for installation in a residence built on
site or a manufactured residence completed at final site. The design
of this furnace line is NOT A.G.A/C.G.A. certified for installation
in recreation vehicles or outdoors.
These furnaces SHALL NOT be installed directly on carpeting,
tile, or any other combustible material other than wood flooring. In
downflow installations, factory accessory floor base MUST be
—2—
28
9
"
16
"
16
TYP
TRAP LOCATION
(DOWNFLOW &
OR ALTERNATE
-IN. DIA GAS CONN
2
1
30
"
2
1
18
"
4
CONDENSATE
DRAIN LOCATION
"
16
(UPFLOW)
DIMPLE LOCATORS
FOR HORIZONTAL
HANGING
19-1/2
19-1/2
19-1/2
1
"
2
15
26
"
16
1
26
"
4
22
5
"
16
13
19"
"
16
5
"
8
OUTLET
2-IN. COMBUSTION-
AIR CONN
5
"
16
1
-IN. DIA
2
GAS CONN
7
-IN. DIA
8
POWER CONN
1
-IN. DIA
2
THERMOSTAT ENTRY
7
39
"
8
2-IN. VENT CONN
11
22
"
16
SIDE INLET
1"
1
7
22
" TYP
"
4
16
3
24
"
11
"
16
16
BOTTOM INLET
A99111
E
16
16
16
16
16
16
16
23
23