International comfort products N9MP1 Service Manual page 17

Multi position 90% single stage gas furnaces
Hide thumbs Also See for N9MP1:
Table of Contents

Advertisement

Single Stage Multi Position Furnace
switch, and permit the burner to operate. As the condensate
drain begins to back−up, however, the pressure begins to
reduce. When the pressure drops sufficiently, burner opera-
tion will be prevented until the condition is corrected.
N9MP1 STANDARD TRANSITION SWITCH
MODEL
PART #
050B12C
1013802
075B12C
1013802
080F16C
1013811
100F14C
1013801
100J20C
1013802
125J20C
1013166
N9MP1 STANDARD INDUCER SWITCH
MODEL
PART #
125J20C
1013166
N9MP1 HIGH ALTITUDE TRANSITION SWITCH
MODEL
PART #
050B12C
1013803
075F12C
1013803
080F16C
1013812
100F14C
1013803
100J20C
1013803
125L20C
1013157
N9MP1 HIGH ALTITUDE INDUCER SWITCH
MODEL
PART #
125J20C
1013157
Figure 13
Pressure Switch
Pressure Port
440 08 2011 00
OPEN " W.C.
CLOSE" W.C
−2
−2.2
−2
−2.2
−1.6
−1.8
−2.1
−2.3
−2
−2.2
−1.6
−1.8
OPEN " W.C.
CLOSE " W.C.
−1.1
−1.3
OPEN " W.C.
CLOSE " W.C.
−1.8
−2
−1.8
−2
−1.3
−1.5
−1.8
−2
−1.8
−2
−1.5
−1.7
OPEN " W.C.
CLOSE " W.C.
−0.7
−0.9
Normally Open
Terminal
Common
Terminal
N9MP2 STANDARD TRANSITION SWITCH
MODEL
PART #
050B12C
1013802
075B12C
1013801
080F16C
1013811
100F14C
1013801
100J20C
1013802
125J20C
1013166
N9MP2 STANDARD INDUCER SWITCH
MODEL
PART #
125J20C
1013166
N9MP2 HIGH ALTITUDE TRANSITION SWITCH
MODEL
PART #
050B12C
1013803
075F12C
1013803
080F16C
1013812
100F14C
1013803
100J20C
1013803
125L20C
1013157
N9MP2 HIGH ALTITUDE INDUCER SWITCH
MODEL
PART #
125J20C
1013157
*9MPD STANDARD TRANSITION SWITCH
MODEL
PART #
050B12C
1013802
075B12C
1013802
080F16C
1013812
100F14C
1013802
100J20C
1013802
125J20C
1013166
*9MPD STANDARD INDUCER SWITCH
MODEL
PART #
125J20C
1013166
*9MPD HIGH ALTITUDE TRANSITION SWITCH
MODEL
PART #
050B12C
1013803
075B12C
1013803
080F16C
1013813
100F14C
1013803
100J20C
1013803
125L20C
1013157
*9MPD HIGH ALTITUDE INDUCER SWITCH
MODEL
PART #
125J20C
1013157
To insure continued SAFE, RELIABLE, operation NEVER
SUBSTITUTE a pressure switch with one that is similar in
Service Manual
OPEN " W.C.
CLOSE" W.C
−2
−2.2
−2.1
−2.3
−1.6
−1.8
−2.1
−2.3
−2
−2.2
−1.6
−1.8
OPEN " W.C.
CLOSE " W.C.
−1.1
−1.3
OPEN " W.C.
CLOSE " W.C.
−1.8
−2
−1.8
−2
−1.3
−1.5
−1.8
−2
−1.8
−2
−1.5
−1.7
OPEN " W.C.
CLOSE " W.C.
−0.7
−0.9
OPEN " W.C.
CLOSE" W.C
−2
−2.2
−2
−2.2
−1.3
−1.5
−2
−2.2
−2
−2.2
−1.6
−1.8
OPEN " W.C.
CLOSE " W.C.
−1.1
−1.3
OPEN " W.C.
CLOSE " W.C.
−1.8
−2
−1.8
−2
−1
−1.2
−1.8
−2
−1.8
−2
−1.5
−1.7
OPEN " W.C.
CLOSE " W.C.
−0.7
−0.9
17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

N9mp2H9mpdC9mpdT9mpd

Table of Contents