Lincoln Electric MAGNUM 250 Operator's Manual page 18

Lincoln electric welder user manual
Table of Contents

Advertisement

D-2
TRIM CORE TUBE FLUSH WITHIN ± .125 (3.18mm)
N O T B E C U T O R D A M A G E D .
I N S U L A T I O N O N T H E C O N T R O L W I R E S M U S T
O F C A B L E J A C K E T . C O R E T U B E M A Y R E T R A C T
1 . 0 0 0 ( 2 5 . 4 m m )
. 3 0 ( 7 . 6 m m ) M A X I M U M A F T E R T R I M M I N G .
C O P P E R
. 8 7 5 ( 2 2 . 2 m m )
W H I T E
S T R A N D I N G
R E D
T R I M C O R E T U B E F L U S H W I T H I N ± . 1 2 5 ( 3 . 1 8 m m )
( 4 P L A C E S )
. 1 6 ( 4 . 0 1 m m )
S K I N
G U N E N D
3 . 5 0 ( 8 8 . 9 m m )
3 . 2 5
S K I N W H I T E A N D R E D L E A D S O N L Y
T O D I M E N S I O N S H O W N , D O N O T S K I N
L E A D L E N G T H
T H E B L U E O R T H E B L A C K L E A D .
( 8 2 . 6 m m )
OF CABLE JACKET. CORE TUBE MAY RETRACT
.30 (7.6mm) MAXIMUM AFTER TRIMMING.
the outer jacket as shown in (Figure D.1). Be care-
ful not to cut the insulation on the control wires while
stripping jacket. Strip the red and white control
leads 1/4 inch (6.4 mm) from the end and crimp a
new S19492-2 terminal to each lead.
note: The cable contains four control leads. Any
two control leads can be used, provided the two col-
ors used are the same at both ends. The extra leads
are spares that can be used if one of the other leads
breaks.
g. Check that the cable boot and both halves of the
strain relief are on the cable. Slip the connector nut
over the copper strands with the thread end out.
Orient gun tube connector so machined flat is on
the same side of the cable as the red and white con-
trol leads.
Assemble gun tube connector to cable by forcing
S P R I N G B O O T
S P R I N G B O O T R E T A I N E R
C A B L E
S T R A I N R E L I E F H O U S I N G
C O N N E C T O R T U B E
C O P P E R S T R A N D S
MAINTENANCE
FIGURE D.1
1.000 (25.4mm)
.875 (22.2mm)
COPPER
STRANDING
FIGURE D.2
CABLE
SPRING BOOT RETAINER
SPRING BOOT
MAGNUM® PRO 250, 350, 450 & 550 AMP
3.50 (88.9mm)
3.25
(82.6mm)
(4 PLACES)
SKIN WHITE AND RED LEADS ONLY
TO DIMENSION SHOWN, DO NOT SKIN
THE BLUE OR THE BLACK LEAD.
.16 (4.01mm)
SKIN
RED
GUN END
WHITE
INSULATION ON THE CONTROL WIRES MUST
NOT BE CUT OR DAMAGED.
the steel tube of the connector into the inside diam-
eter of the cable inner tube until the copper strands
are butted against the gun tube connector shoulder.
Keeping the copper strands against the shoulder,
pull the connector nut over the copper strands,
engage the gun tube connector threads, and tight-
en in place. Refer to (Figure D.2).
note: For best results, insert a .219"/.240" (5.6/
6.1 mm) diameter rod through the connector and
into core of cable approximately 5.00 (127 mm)
when pushing the connector tube into the cable
core tube. To tighten, hold the connector in place
while turning the nut, then remove the rod from the
core. This procedure ensures the inner core does
not kink while assembling or tightening.
h. Pull the cut-off lead terminals off the trigger assem-
CONNECTOR TUBE
ST RAIN RELIEF HOUSING
LEAD LENGTH
COPPER STRANDS
D-2