Lincoln Electric CV ADAPTER IM309-D Operator's Manual page 17

Lincoln electric welder user manual
Table of Contents

Advertisement

B-8
8. Connect CV Adapter leads "Neg" and "Pos" to the
back of the SA-250 negative and positive output
terminals respectively. Tape these leads to gener-
ator lead bundle for support.
NOTE: FOR STEPS 9 THROUGH 11, REFER TO FIG-
URES 10 AND 11.
FIGURE 11 – View of Negative Generator Brushholder after Bracket Cover is Removed.
INSTALLATION
FIGURE 10 – SA-250 with Roof Assembly Removed.
CV ADAPTER
9. The negative generator brushholder, exposed
when bracket cover (see Figure 10) is removed, is
at the 11 o'clock position when the commutator is
viewed from the control panel end of welder.
Remove the 5/16 bolt which connects the two
existing cables to the negative brushholder. Locate
the thermostat assembly marked "250" and recon-
nect the two cables to the negative brushholder
with one end of the thermostat assembly bolted
between the cable lugs and the brushholder.
B-8