B. Chimney Diagram
Sidewalk
V
=Vent Terminal
Figure 4.10
Requirements for Terminating the Venting
!
Venting terminals must not be recessed into a wall
or siding.
Only PL vent pipe wall pass-through and fire stops
should be used when venting through combustible
materials.
Always take into consideration the effect the prevailing
wind direction or other wind currents will cause with
flyash and /or smoke when placing the termination.
In addition, the following must be observed:
A. The clearance above grade must be a minimum of 12".
B. The clearance to a window or door that may be opened must
be a minimum of 48" to the side and 48" below the window/
door, and 12" above the window/door. (with outside air
installed, 9" to side and below)
C. A 12" clearance to a permanently closed window is
recommended to prevent condensation on the window.
D. The vertical clearance to a ventilated soffit located above the
terminal within a horizontal distance of 2 feet (60 cm) from the
center-line of the terminal must be a minimum of 18".
E. The clearance to an unventilated soffit must be a minimum of
12".
F. The clearance to an outside corner is 11" from center of pipe.
G. The clearance to an inside corner is 12".
H. A vent must not be installed within 3 feet (90 cm) above a gas
meter/regulator assembly when measured from the horizontal
center-line of the regulator.
15
Inside Corner
Detail
Fixed
Closed
Openable
A
WARNING
NOTE
Harman® • Absolute43 Installation Manual_R2 • 2015 - ___ • 03/15
Openable
Fixed
Closed
=Air Supply Inlet
I. The clearance to service regulator vent outlet must be a
minimum of 6 feet.
J. The clearance to a non-mechanical air supply inlet to the
building or the combustion air inlet to any other appliance must
be a minimum of 48".
K. The clearance to a mechanical air supply inlet must be a
minimum of 10 feet. (with outside air installed, 6 feet)
L. The clearance above a paved sidewalk or a paved driveway
located on public property must be a minimum of 7 feet.
M. The clearance under a veranda, porch, deck or balcony must
be a minimum of 12 inches. (B. also)
The clearance to vegetation and other exterior
combustibles such as mulch is 36" as measured
from the center of the outlet or cap. This 36" radius
continues to grade or a minimum of 7 feet below the
outlet.
Certain Canadian and or Local codes or regulations may require
different clearances.
A vent shall not terminate directly above a side-walk or paved
driveway which is located between two single family dwellings
and serves both dwellings.
Only permitted if veranda, porch, deck, or balcony is fully open on
a minimum of 2 sides beneath the floor.
See NFPA 211 for more installation clearance reductions when
using outside air.
where passage through a wall, or partition of
combustible construction is desired, the installation
shall conform to CAN/CSA-B365. (if in Canada)
Porch or
Openable
=Area where termination is not permitted
NOTE
NOTE
Deck
or Fixed
3-90-00778i