9.4 DISCHARGE CHUTE
WARNING: DO NOT put hands or feet near or
under rotating parts. Keep clear of discharge
opening at all times.
WARNING: NEVER direct discharge of
material toward bystanders nor allow anyone
in front of equipment while unit is in operation.
Be familiar with area of operation.
Remove mounting clips from discharge chute, oil and
position chute on auger/impeller housing. Secure
discharge chute with mounting clips and hardware.
1. Chute Crank
2. Gear Cover
3. Pinion Gear
4. Chute Gear
5. Chute Support Bracket
NOTE: Chute must rotate freely. To adjust the gears
tighten or loosen the lower nut (Figure 20). This will
adjust the spring tension on the gears.
1
5
6
7
8
6. Friction Plate
7. Compression Spring
8. Locking Center Nut
Figure 20
9 - 27
2
3
4
PS0601