Specific Issues and Workarounds Concerning Solaris (Continued)
TABLE 7
CR ID
Description
6589546
prtdiag(8) command does not show all I/O
devices of the following cards:
• SG-XPCIE2FC-EM4 Sun StorageTek
Enterprise Class 4Gb Dual-Port Fibre
Channel PCI-E HBA
• SG-XPCIE1FC-EM4 Sun StorageTek
Enterprise Class 4Gb Single-Port Fibre
Channel PCI-E HBA
6589833
The DR addboard(8) command might cause a
system hang if you are adding a Sun
StorageTek Enterprise Class 4Gb Dual-Port
Fibre Channel PCI-E HBA card (SGXPCIE2FC-
QF4) at the same time that an SAP process is
attempting to access storage devices attached
to this card. The chance of a system hang is
increased if the following cards are used for
heavy network traffic:
• X4447A-Z, PCI-e Quad-port Gigabit
Ethernet Adapter UTP
• X1027A-Z1, PCI-e Dual 10 Gigabit Ethernet
Fiber XFP Low profile Adapter
6592302
Unsuccessful DR operation leaves memory
partially configured.
6600730
Extra characters appear in a boot message
string.
6608404
Hot-plug of the X4447A-Z, PCI-e Quad-port
Gigabit Ethernet Adapter UTP card in slot 1
might cause other network devices to fail.
6619344
The Sun Crypto Accelerator (SCA) 6000 card
might not work if hot-plug configured into slot
1.
Workaround
Use prtdiag -v for full output.
There is no workaround. Check for the
availability of a patch for this defect.
Try deleteboard(8) again.
The extraneous characters can be safely
ignored.
To avoid the defect, do not install this card in
slot 1.
To avoid the defect, do not hot-plug this card
in slot 1.