Konica Minolta inpro Technical Manual

Ip reader

Advertisement

Quick Links

Inepro IP Reader
(Konica Minolta)
Technical Manual | Inepro IP Reader (Konica Minolta)
Product Version: Rev. 3
Version of this manual: 2.0.1
© 2014 Inepro B.V. All rights reserved

Advertisement

Table of Contents
loading

Summary of Contents for Konica Minolta inpro

  • Page 1 Inepro IP Reader (Konica Minolta) Technical Manual | Inepro IP Reader (Konica Minolta) Product Version: Rev. 3 Version of this manual: 2.0.1 © 2014 Inepro B.V. All rights reserved...
  • Page 2 Inepro IP Reader (Konica Minolta) The most versatile card reader solution Congratulations on your selection of Inepro card readers. We are certain you will be pleased with your purchase of one of the flexibele solutions of the market. We want to help you get the best result from your Inepro Back Office Suite. This manual contains information on how to do that;...
  • Page 3 Inepro IP Reader (Konica Minolta) All rights reserved. No parts of this work may be reproduced in any form or by any means - graphic, electronic, or mechanical, including photocopying, recording, taping, or information storage and retrieval systems - without the written permission of the publisher.
  • Page 4: Table Of Contents

    Table of Contents Introduction Components Operating Procedures Communication Network Connections LEDs (Light Emitting Diodes) Software configuration settings Inepro Business Server (Optional) Specifications Appendix I...
  • Page 5 Directives ATTENTION!! Read this manual carefully before installing the IP Reader! Mains connection Before connecting the appliance to the mains, check that the mains supply voltage corresponds to the voltage printed on the type plate of the adapter. If the mains voltage is different, consult your supplier.
  • Page 6: Introduction

    Introduction Part...
  • Page 7 Introduction Introduction In this manual you find the instructions to install and configure your IP-reader. This manual is meant for all the Konica Minolta IP-readers. This manual, the IP reader hardware and software are subject to change, make sure you have the latest version of this manual, because the older versions may have become obsolete.
  • Page 8 Topics The following topics will be addressed: 1. The components in the IP-reader set 2. The operating procedures 3. Network Connections 4. Software configuration settings 5. Connecting to the Business Server Inepro IP Reader (Konica Minolta)
  • Page 9: Components

    Components Part...
  • Page 10 - Antenna Box Cap 1 / Grey - Antenna Box Cap 2 / Grey · Controller Box · Wire Duct - Grey · Network Cables - Network Cable UTP C5E Patch Black (0,5mtr.) - Network Cable UTP C5E Patch Black (2,0mtr.) Inepro IP Reader (Konica Minolta)
  • Page 11 Components · Power Supply AC/DC 12 Volts, 7 Watt - Power Supply Unit - 3x Socket Adapter · Screw set - 2x Screw self tapping cross head dome 3,5 x 9,5 mm · Download Guide Inepro Manuals · Cable clip - Cable clip PK 250 - Self Adhesive Fastener 6 x 6 mm Check Components...
  • Page 12: Operating Procedures

    Operating Procedures Part...
  • Page 13 Operating Procedures Operating Procedures The card reader is connected to the IP controller board by the card reader cable. Using this cable the IP controller board communicates with the card reader. When a card is presented to the reader it will read the card’s data. The IP controller board makes a request to the card reader for the data.
  • Page 14: Communication

    Communication Part...
  • Page 15 Communication Communication Communication between the card reader and the IP Controller Board The communication between one of the supported card reader and the IP Controller board is done by a protocol (a definition of communication codes or language by which they can communicate).
  • Page 16 IP Reader encryption protocol Inepro IP Reader (Konica Minolta)
  • Page 17: Network Connections

    Network Connections Part...
  • Page 18 "no PoE" Ethernet connector), nothing will be damaged. In that case the IP controller won't have energy and will not operate. Switching the Ethernet cable to the "PoE" connector will activate the IP controller board. Inepro IP Reader (Konica Minolta)
  • Page 19 Network Connections IP READER OVERVIEW Power over Ethernet No Power over Ethernet Orange LED = Blinking Orange LED = On Green LED = On Green LED = Blinking IP Controller Board Ethernet Connections IP Controller Board IP Controller Board LED's RS232 Led on = Communication between -->...
  • Page 20: Leds (Light Emitting Diodes)

    LEDs (Light Emitting Diodes) Part...
  • Page 21 LEDs (Light Emitting Diodes) LEDs (Light Emitting Diodes) Antenna Housing LED Inside the card reader’s housing a LED is mounted which can be used to let the user know that card data has been read and this data is presented to the server. The LED will also be used to show an error has occurred, by using different blink patterns.
  • Page 22 Header or trailer of an error code Long Pulse Error code Short Pulse Reader Status Code Non-Wiegand Card reader not responding 9 error pulses (-..-) Error in the EEPROM configuration of IP 10 error pulses (-..-) Controller board Inepro IP Reader (Konica Minolta)
  • Page 23 LEDs (Light Emitting Diodes) IP Controller Board LED's Status Display Connection between card reader and IP Controller board. RS232 Card reader (that does not allow access actively), sends data to the IP controller board. *1 Blink every Running OK 0.5 sec. Card present Card not present Card reader cannot be actively...
  • Page 24 (or green Bad or slow speed, modulated on the PoE) connection data transmission blink signal With the PoE connector, the status of the green LED will be that of the orange LED and vice versa. Inepro IP Reader (Konica Minolta)
  • Page 25: Software Configuration Settings

    Software configuration settings Part...
  • Page 26 When you start the configuration set-up program this screen will be displayed. Press the button to search for connected IP Readers. This next screen will display the IP Readers that were found by the configuration set-up program. Inepro IP Reader (Konica Minolta)
  • Page 27 Software configuration settings Please note that the IP address of the IP Reader has not been applied (0.0.0.0). Provided the DHCP server is up and running, the next screen will be displayed The DHCP server has found the IP Reader and has displayed the host name "PoE Test".
  • Page 28 Internet and your local network). It is usually the same address as the DNS server. Domain Name The IP address of the server with the Domain Name System, the system that System transforms names to IP-addresses and vice versa. Inepro IP Reader (Konica Minolta)
  • Page 29 Software configuration settings Server config settings Description Server 1 IP The address of the server that the IP reader should contact. The address of the back-up server that the IP reader should contact. It will be Server 2 IP contacted if the first server does not respond. When DNS is used the name of the server can be entered, the IP-address Server 1 name value for this server will be ignored, and retrieved from the DNS server.
  • Page 30 IP reader will check if the code on the card is present. If the value is '0' the facility code is not checked. Data 1 Not applicable Data 2 Not applicable Note: The facility code is never send to the server. Inepro IP Reader (Konica Minolta)
  • Page 31 Software configuration settings Multi tag: Setting Description Value Card Types Behaviour EM4x50, hitag1, hitag2, Q5 and Ti-RFID EM4x02, EM4x05, IP reader will read the EM4x50, hitag1, following protocols: hitag2 and Ti-RFID EM4x02, EM4x05, EM4x02, EM4x05, The card data of the EM4x50, hitag1, hitag2, Q5 EM4x50, hitag1, EM4x02 cards will be...
  • Page 32 Data 2 Not applicable Note: When you can't find your card reader type in these tables, please contact Inepro for the settings for your reader. They will send you the latest version of this manual. Inepro IP Reader (Konica Minolta)
  • Page 33: Inepro Business Server (Optional)

    Inepro Business Server (Optional) VIII Part...
  • Page 34 Back Office Suite module. You will not need or be able to execute these instructions if you do not posses this module. If you do not posses this module, please skip this chapter. The symbol in our manuals will tell you that a module is optional. Inepro IP Reader (Konica Minolta)
  • Page 35 Inepro Business Server (Optional) Connect the IP reader to the Inepro Business server 1. Start the Inepro Business Server Config settings manager (this will be installed in the Back Office Suite directory, by default in the 'C:\Program Files\Inepro' directory). 2. Right-click on 'System default' and choose 'Insert' from the menu.
  • Page 36 9. Click on OK and the reader is registered in the Inepro Back Office Suite. 10.Repeat this process for all the other readers. 11.When you have finished registering the IP readers, restart the Business server. Inepro IP Reader (Konica Minolta)
  • Page 37 Inepro Business Server (Optional) Connect to the Inepro Back Office Manager 12.After the Business server has started again you should be able to find the reader that have been registered in the Inepro Back Office Manager in the 'Advanced' -> 'Terminals' menu : 13.These terminals can now be connected to a Multifunctional, like you would connect a PayCon terminal.
  • Page 38: Specifications

    Specifications Part...
  • Page 39 Specifications Specifications Power Switch regulated, high efficiency Power Supply (via adapter) 12V DC adapter 1VA Confirm IEEE 802.3 AF Power Supply (via PoE) specifications Operation Voltage Range DC (via adapter) 10 to 20V DC Operation Voltage Range DC (via PoE) 40 to 60V DC At maximum (depending on Power Consumption...
  • Page 40 <This page is blank intentionally> Inepro IP Reader (Konica Minolta)
  • Page 41 Appendix I Part...
  • Page 42 Inepro IP Reader (Konica Minolta)

Table of Contents